5-PORT SPOOL OPERATED VALVE

501 SERIES (IN-LINE type)

501 SERIES (IN-LINE type)

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.15 ~ 0.9MPa
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

501 SERIES (TOUCH MANIFOLD TYPE)

501 SERIES (TOUCH MANIFOLD TYPE)

SPECIFICATIONS

Pipe
Size
“1” “3” “5” port
(common port)
Rc 1/4 (on sides of manifold block)
“2” “4” port
(separate port)
Rc 1/4 (on each valve body)
Effective Area
(IN-OUT/OUT-EX)
21/18mm² 2 position Single / Double solenoid
18/13mm² 3 position Double solenoid
Max. no. of valves possible
on the manifold block
8

* Other specifications are common to 501 Series, In-line type.


MVS(D)-495Y SERIES (In-line type)

MVS(D)-495Y SERIES (In-line type)

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.2 ~ 0.95MPa
(Internal Pilot Supply type)
0 ~ 0.95MPa
(External Pilot Supply type)
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS ISO VG 32 turbine oil, or
equivalent oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

MVS(D)-495Y SERIES (Stack Manifold type)

MVS(D)-495Y SERIES (Stack Manifold type)

SPECIFICATIONS

Pipe
Size
“1” “3” “5” port
(common port)
Rc 3/8 (on both end plates)
“2” “4” port
(separate port)
Rc 1/4 or Rc 3/8 (on each valve body)
Effective Area 35mm²
Maximum number of
valves available for
forming stack manifold
8

* Other specifications are common to 495Y Series, In-line type.


MVS(D)-492Y SERIES (Sub-Base type )

MVS(D)-492Y SERIES (Sub-Base type )

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.2 ~ 0.95MPa
(Internal Pilot Supply type)
0 ~ 0.95MPa
(External Pilot Supply type)
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

MVS(D)-492Y SERIES (Manifold type)

MVS(D)-492Y SERIES (Manifold type)

SPECIFICATIONS

Pipe
Size
“1” “3” “5” port
(common port)
Rc 1/2 (on manifold block)
“2” “4” port
(separate port)
Rc 1/4 or Rc 3/8 (on manifold block)
Effective Area 35mm²
Maximum number of valves
available for manifold
10

* Other specifications are common to 492Y Series, Sub-base type.


524 SERIES (Sub-Base type)

524 SERIES (Sub-Base type)

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.2 ~ 1.0MPa
(Internal Pilot Supply type)
0 ~ 1.0MPa
(External Pilot Supply type)
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

524 SERIES (Manifold type)

524 SERIES (Manifold type)

SPECIFICATIONS

Port
Size
“1” “3” “5”
common ports
Rc 3/4
“2” “4” port
Each valve port
Rc 3/8 , Rc 1/2 or Rc 3/4
Effective Area 75mm²
Maximum No. of valves
available for manifold
6

492Y SERIES SUB-BASE TYPE

492Y SERIES SUB-BASE TYPE

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.15 ~ 1.0MPa
(Internal Pilot Supply type)
0 ~ 1.0MPa
(External Pilot Supply type)
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS Turbine oil ISO VG 32 or equivalent
oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

MVS(D)-4900 SERIES

MVS(D)-4900 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0 ~ 1.0MPa
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

4-PORT POPPET OPERATED SOLENOID VALVE

460 Super Poppet SERIES (2-position)

460 Super Poppet SERIES (2-position)

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.15 ~1.0MPa
(Internal Pilot Supply type)
0.05 ~ 1.0MPa
(External Pilot Supply type)
AMBIENT TEMPERATURE 5 ~ 50°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

460 Super Poppet SERIES (3-position)

460 Super Poppet SERIES (3-position)

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.15 ~1.0MPa
(Internal Pilot Supply type)
0.05 ~ 1.0MPa
(External Pilot Supply type)
AMBIENT TEMPERATURE 5 ~ 50°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

3-PORT POPPET OPERATED SOLENOID VALVE

360 Super Poppet SERIES

360 Super Poppet SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.15 ~1.0MPa
(Internal Pilot Supply type)
0.05 ~ 1.0MPa
(External Pilot Supply type)
AMBIENT TEMPERATURE 5 ~ 50°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

360 Super Poppet SERIES (vacuum)

360 Super Poppet SERIES (vacuum)

SPECIFICATIONS

FLUID Vacuum (air)
OPERATING PRESSURE – 0.1 ~ –0.01MPa
(External Pilot Supply Type only)
EXTERNAL PILOT SUPPLY PRESSURE 0.2 ~ 0.3MPa
AMBIENT TEMPERATURE 5 ~ 50°C
PROOF PRESSURE 1.6MPa
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

360 Super Poppet SERIES (High-Low pressure change)

360 Super Poppet SERIES (High-Low pressure change)

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE Pressure Range
of Main Valve
Side*
High Pressure Side (IN):
0.05 ~1.0MPa
Low Pressure Side (EX):
0 ~ 0.85MPa
Pilot Pressed:
Set of P*
P = High Pressure Side (IN) Pressure +
0 ~ 0.2MPa Besides
P = Low Pressure Side (EX) Pressure +
0.15MPa
AMBIENT TEMPERATURE 5 ~ 50°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended. (Non-Lubrication is
also available)
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

*1. Higher pressure side = (IN PORT), Lower pressure side = (EX PORT)

*2. Pilot air should be lower than 1.0MPa

*3.Operating pressure range of 36B series (Rc11/4 ~ Rc2) is 0.2 ~ 1.0MPa.


392 SERIES

392 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air Vacuum
OPERATING PRESSURE 0 ~ 0.7MPa – 0.1 ~ 0MPa
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS Can use without lubrication
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

2-PORT SOLENOID VALVE

MVS-2200Y, MVS-2300Y SERIES

MVS-2200Y, MVS-2300Y SERIES

SPECIFICATIONS

FLUID Compressed Air Liquid* Vacuum
OPERATING PRESSURE RANGE 0.02 ~ 0.7MPa 0.15 ~ 0.7MPa – 0.08 ~ 0MPa
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANT Required
MANUAL OPERATION Nil
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

* Use non-corrosive and low viscosity liquid.

BASIC MODEL NOs. & OTHER SPECIFICATIONS

Pipe
Size
MODEL NUMBER Effective Area
[mm²]
< Cv value >
Single Solenoid Normally Closed Mass
[kg]
Compressed Air / Liquid Vacuum
Rc 1/4 MVS-2202Y MVS-2202YV 0.5 35 < 1.9 >
Rc 3/8 MVS-2203Y MVS-2203YV 40 < 2.2 >
Rc 1/2 MVS-2204JY MVS-2204JYV
Pipe
Size
MODEL NUMBER Effective Area
[mm²]
< Cv value >
Single Solenoid Normally Closed Mass
[kg]
Compressed Air / Liquid Vacuum
Rc 1/2 MVS-2304Y MVS-2304YV 1.5 110 < 5.9 >
Rc 3/4 MVS-2306Y MVS-2306YV 170 < 9.2 >
Rc1 MVS-2310Y MVS-2310YV 240 < 13.0 >
Rc1 1/4 MVS-2312JY MVS-2312JYV 350 < 18.9 >

260 Super Poppet SERIES

260 Super Poppet SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.15 ~1.0MPa
(Internal Pilot Supply type)
0.05 ~ 1.0MPa
(External Pilot Supply type)
AMBIENT TEMPERATURE 5 ~ 50°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent oil is recommended.
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

260 Super Poppet SERIES (vacuum)

260 Super Poppet SERIES (vacuum)

SPECIFICATIONS

FLUID Vacuum (air)
OPERATING PRESSURE – 0.1 ~ 0MPa
(External Pilot Supply type only)
EXTERNAL PILOT SUPPLY PRESSURE 0.2 ~ 0.3MPa
AMBIENT TEMPERATURE 5 ~ 50°C
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V  • DC-100V
VOLTAGE ALLOWANCE –15 ~ 10%
INSULATION GRADE Class B

DUAL VALVES

354 SERIES, MVS-3500YCG/YCL/YCK SERIES

354 series, MVS-3500YCG/YCL/YCK SERIES

SPECIFICATIONS

  354 Series MVS-3500Y Series
FLUID Filtered Compressed Air
OPERATING PRESSURE 0.20 ~ 0.85MPa
(Internal Pilot)
0.15 ~ 0.8MPa
(Internal Pilot)
0.05 ~ 0.85MPa
(External Pilot)
0.05 ~ 0.8MPa
(External Pilot)
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS Available without supplying oil. (No lubrication) ISO VG32 turbine oil, or equivalent  oil is recommended.
MANUAL OPERATION Mnual push button / Non-lock type
RATED VOLTAGE • AC-100V 50/60Hz, 110V 60Hz
• AC-200V 50/60Hz, 220V 60Hz
• DC-24V
VOLTAGE ALLOWANCE ±10% –15 ~ 10%
INSULATION GRADE Class B

SILENCER

MFF-200, 300 SERIES

MFF-200, 300 SERIES

SPECIFICATIONS

FLUID Exhaust Air
MAX. OPERATING PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
EXHAUST NOISE REDUCTION RATE More than 20 dB (A)
NOISE REDUCING ELEMENT SL-00 Series: sintered brass
MFF-200 Series: plastic foam
MFF-300 Series: wire-mesh element,
or non-woven sheet.

MODEL NOs. & OTHER SPECIFICATIONS

Pipe
Size
MODEL NUMBER Effective Area
(mm²)<Cv>
Mass
(kg)
R 1/4 SL-02 40 < 2.2 > 0.02
R 3/8 SL-03 60 < 3.2 > 0.03
R 1/2 MFF-204 115 < 6.2 > 0.09
R 3/4 MFF-306A 230 < 12.4 > 0.20
R1(Rc1) MFF-310 330 < 17.8 > 0.62
Rc1 1/4 MFF-312 915 < 49.4 > 0.9
Rc1 1/2 MFF-314 975 < 52.7 >
Rc2 MFF-320 1400 < 75.6 > 1.5

 
PDF catalog Azbil TA- Fluid Control Technology at Its Best General Catalogue