AIR REGULATOR

R31 SERIES

R31 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
RELIEF Relieving and Non-relieving
ADJUSTMENT Snap lock knob type (one touch lock)

RK-1206 SERIES

RK-1206 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
ADJUSTING PRESSURE RANGE •0.02 ~ 0.8MPa
•0.01 ~ 0.4MPa
RELIEF Relieving
PIPE SIZE Inlet port
(common)
Rc3/4 at both sides
Outlet port Rc1/2 at each regulator
Gauge port Rc1/8 at each regulator

NRV-300, 200 SERIES

NRV-300, 200 SERIES

SPECIFICATIONS

SERIES NRV-300 NRV-200
FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE* 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Directly operated by spring
ADJUSTING PRESSURE RANGE •0.02 ~ 0.8MPa (Std.)
•0.01 ~ 0.3MPa
•0.01 ~ 0.1MPa
•0.1 ~ 1.6MPa *
RELIEF Relieving Non-relieving

* Max Inlet pressure: 2.8MPa for units of ~1.6MPa range.

* 0.1~1.6MPa range is available for units of pipe size of 1/4,3/8 and 1/2.

BASIC MODEL NOs. & OTHERS

Pipe Size MODEL NUMBER Gauge Port Mass(kg)
Relieving Non-relieving
Rc1/4 NRV-302 NRV-202 Rc1/8
(2 places)
1.2
Rc3/8 NRV-303 NRV-203
Rc1/2 NRV-304 NRV-204 1.4
Rc3/4 NRV-306 NRV-206 2.9
Rc1 NRV-310 NRV-210 2.7

NRV-400 SERIES

NRV-400 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Integral pilot operated type (Internal pilot type)
ADJUSTING PRESSURE RANGE •0.02 ~ 0.7MPa (Std.)
•0.01 ~ 0.4MPa
•0.01 ~ 0.2MPa
•0.1 ~ 1.6MPa*
RELIEF Relieving and Non-relieving

* Max Inlet pressure is 2.8MPa in case of units of 0.1~1.6MPa range.

BASIC MODEL NOs. & OTHERS

Pipe
Size
MODEL NUMBER Adjusting Pressure Range Gauge Port Mass
(kg)
Rc1/2 NRV-404 0.2 ~ 0.7Mpa Rc1/8
(2 places)
1.7
NRV-404K4 0.01 ~ 0.4Mpa
NRV-404K2 0.01 ~ 0.2Mpa
Rc3/4 NRV-406 0.02 ~ 0.7Mpa 3.1
NRV-406K4 0.01 ~ 0.4Mpa
Rc1 NRV-410 0.02 ~ 0.7Mpa 3.0
NRV-410K4 0.01 ~ 0.4Mpa

RVD-400YF SERIES

RVD-400YF SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Integral pilot operated type (Internal pilot type)
ADJUSTING PRESSURE RANGE 0.02 ~ 0.8MPa
RELIEF Relieving and Non-relieving

NRV-500 SERIES

NRV-500 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Remote controlled type (External pilot operated type)
OUTLET PRESSURE
ADJUSTING RANGE
0.02 ~ 0.8MPa
(within the limits of pilot regulator)
RELIEF Relieving and Non-relieving

RVD-500YF SERIES

RVD-500YF SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Remote controlled type (External pilot type)
ADJUSTING PRESSURE RANGE 0.02 ~ 0.8MPa
RELIEF Relieving and Non-relieving

R50 SERIES

R50 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
Use air filter with 5μm element.
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Integral Feed-back pilot operated
(Internal Pilot type)
ADJUSTING PRESSURE RANGE 0.05 ~ 0.8MPa
RELIEF High-relieving
STANDARD EQUIPPED PART Bracket and Adapter for connecting pressure gauge

R50-R SERIES

R50-R SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Feed-Back Pilot Remote control type
(External Pilot operated type)
ADJUSTING PRESSURE RANGE 0.05 ~ 0.8MPa
Depends on adjusting pressure range of pilot regulator.
RELIEF High-relieving
EQUIPPED PART WITH
STANDARD MODEL
Bracket and Adapter for connecting pressure gauge

R50-M SERIES

R50-M SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Remote controlled type
(External Pilot operated type)
ADJUSTING PRESSURE RANGE 0.05 ~ 0.8MPa
Depends on adjusting pressure range of pilot regulator.
RELIEF High-relieving
EQUIPPED PART WITH
STANDARD MODEL
Bracket and Adapter for connecting pressure gauge

NRV-802 SERIES

NRV-802 SERIES

SPECIFICATIONS

MODEL NUMBER NRV-802 NRV-802K16 NRV-802K4 NRV-802K2
PIPE SIZE Rc1/4
FLUID Filtered Clean Air (Use 25μm filter element)
MAXIMUM INLET PRESSURE* 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
ADJUSTING PRESSURE RANGE 0.02 ~ 0.7MPa 0.1 ~ 1.6MPa 0.01 ~ 0.4MPa 0.01 ~ 0.2MPa
OPERATION Directly operated and constant bleed type
RELIEF Relieving type
GAUGE PORT Rc1/8
MASS (kg) 0.84

* Max. inlet pressure is 2.8MPa in case of 0.1~1.6MPa range (K16).


NRV-802D SERIES

NRV-802D SERIES

SPECIFICATIONS

MODEL NUMBER NRV-802D
PIPE SIZE Rc1/4 (IN, OUT Port)
FLUID Filtered Clean Air (w/5μm element)
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
FEED BACK PORT Rc 1/8
MASS (kg) 0.95

* For panel mount, add “P” at the end of model no.
Note: This regulator is used only as pilot regulator. In this case, master regulator recommended is R50-M series high relieving type.


NRV-502JD SERIES

NRV-502JD SERIES

SPECIFICATIONS

MODEL NUMBER NRV-502JD
PIPE SIZE Rc1/4 (IN, OUT Port)
Rc1/4 Pilot Air Port
FLUID Filtered Clean Air (w/5μm element)
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
FEED BACK PORT Rc 1/8
MASS (kg) 0.95

R42 SERIES

R42 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
(Use oil removal filter in supply line)
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 0 ~ 70℃
ADJUSTING PRESSURE RANGE •0.04 ~ 0.4MPa
•0.08 ~ 0.8MPa
•0.02 ~ 0.2MPa
OPERATION Integral feed-back controlled constant bleed type
(Constant bleed flow: max. 1.7dm³/min. (ANR)
at inlet pressure: 0.17MPa
outlet pressure: 0
RELIEF Relieving type
MASS(kg) 0.35

NRV-300A SERIES

NRV-300A SERIES

SPECIFICATIONS

MODEL NUMBER NRV-302A NRV-303A NRV-304A
PIPE SIZE Rc 1/4 Rc 3/8 Rc 1/2
FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
ADJUSTING PRESSURE RANGE 0.02 ~ 0.5MPa
STROKE 0 ~ 20mm
FORCE FOR OPERATION OF ADJUSTING ROD Max. 1100N
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Directly spring operated type
RELIEF Relieving
MASS (kg) 1.7

R31, RL4,NRV-1200 SERIES (Water purpose)

R31, RL4,NRV-1200 SERIES (Water purpose)

SPECIFICATIONS

FLUID Water or Non-corrosive and low viscosity liquids
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATION Directly spring operated type
RELIEF Non-relieving

BASIC MODEL NOs. & OTHERS

Series Pipe
Size
MODEL NUMBER Adjusting Pressure Range
MPa
Gauge
Port
Mass
(kg)
R31 Rc 1/8 R31-100-0100-30 0.02 ~ 0.7 Rc 1/8
(2 places)
0.1
R31-100-C100-30 0.01 ~ 0.35
R31-100-B100-30 0.01 ~ 0.07
Rc 1/4 R31-200-0100-30 0.02 ~ 0.7
R31-200-C100-30 0.01 ~ 0.35
R31-200-B100-30 0.01 ~ 0.07
RL4 Rc 1/4 RL4-201-0100 0.02 ~ 0.8 Rc 1/4
(2 places)
2.2
RL4-201-4100 0.01 ~ 0.4
Rc 3/8 RL4-301-0100 0.02 ~ 0.8
RL4-301-4100 0.01 ~ 0.4
Rc 1/2 RL4-401-0100 0.02 ~ 0.8
RL4-401-4100 0.01 ~ 0.4
NRV-
1200
Rc 3/4 NRV-1206 0.02 ~ 0.8 Rc 1/8
(2 places)
4.7
NRV-1206K3 0.01 ~ 0.3
Rc1 NRV-1210 0.02 ~ 0.8
NRV-1210K3 0.01 ~ 0.3

HIGH SET

HS-400Y2 SERIES

HS-400Y2 SERIES

SPECIFICATIONS

MODEL NUMBER HS-404Y2 HS-412Y2 HS-414Y2 HS-420Y2
PIPE SIZE Rc 1/2 Rc1 1/4 Rc1 1/2 Rc2
EXHAUST PORT CONNECTION Pipe connection
is not available
Rc1 1/2 Rc2
LEAD PORT ・ PILOT PORT Rc 1/4
FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60˚C
ADJUSTING PRESSURE RANGE 0.1 ~ 0.8MPa
ALLOWABLE BACK PRESSURE 1.0MPa
CONSTANT FOR CHARGING TIME 1250 100
MASS (kg) 3.5 13

* Dimension of constant for charging time: text


HSP-302 SERIES ( For HS-400Y2 SERIES)

HSP-302 SERIES ( For HS-400Y2 SERIES)

SPECIFICATIONS

FLUID Filtered Compressed Air
MAXIMUM INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 50°C
AIR REGULATOR Relief High sensitive relieving type
Adjusting
Pressure Range
0.2 ~ 0.7MPa
SOLENOID VALVE Operation 3 Way Double Solenoid Pilot operated type
Rated Voltage • AC-100V / 50, 60Hz, 110V 60Hz
• AC-200V / 50, 60Hz, 220V 60Hz
Electric Current AC-100V, 50Hz AC-200V, 50Hz
Inrush Current 0.165A 0.08A
Holding Current 0.102A 0.049A

H30/H50 SERIES

H30/H50 SERIES

SPECIFICATIONS

OPERATING FLUID Filtered Compressed Air(by filter 74μm or less)
SUPPLY PRESSURE to INLET 0.2~0.95MPa
SETTING PRESSURE RANGE 0.1~0.95MPa (Min.pressure increment: 0.01MPa) *1
SET PRESSURE ACCURACY ±1% F. S. (at 25℃)
SUPPLY VOLTAGE DC24V/AC100V(±10%): for H30 Series Contolroller *2
AC100V(±10%): for H50 Seriese Controller

DC24V(±1V):forP/I Converter
AC100V/DC24V(±10%): for H18/1B Control Valve *3

DC24V(±10%): for GOOD signal output
DC24V(±10%): for Interlock signal output
INPUT SIGNAL to CONTROLLER H30 Series: BCD parallel or shift key on front
H50 Series: 0-10VDC signal
AMBIENT TEMPERATURE 5 ~ 50℃
AMBIENT RELATIVE HUMIDITY RH20~85%(FOrming of ice is prohibited)
VIBRATION PROTECTION Contoroller Unit needs vibration protextion.
Mass(kg) Controller: 2.5kg/H30, or 0.5kg/H50
P/I COnverter: 0.4kg
Control Calve: 4kg/H18, or 8.8kg/H1B

*1. Never exceed 0.95MPa during the compress stage of Press work.

*2. H30 Series controller can select the models built-in DC24V supply voltage for external equipment.

*3. Lubrication of the control valve is necessary by ISO VG32 turbine oil.


PRESSURE GAUGE

GAB, GBB SERIES

GAB, GBB SERIES

MODEL NUMBER SPECIFICATIONS
Diameter
of Dial
Pressure Range Pipe Size Pressure Port
Connection
Class
GAB501100 φ50 0 ~ 1.0MPa R 1/8 Center back
connection
B
(3% FS)
GAB501040 φ50 0 ~ 0.40MPa R 1/8
GAB501020 φ50 0 ~ 0.20MPa R 1/8
GBB501100 φ50 0 ~ 1.0MPa R 1/8 Bottom connection
GBB501040 φ50 0 ~ 0.40MPa R 1/8
GAB502100 φ50 0 ~ 1.0MPa R 1/4 Center back
connection
GAB502040 φ50 0 ~ 0.40MPa R 1/4
GAB401100 φ40 0 ~ 1.0MPa R 1/8
GAB401040 φ40 0 ~ 0.40MPa R 1/8
GAB401010 φ40 0 ~ 0.1MPa R 1/8
GAB501200 φ50 0 ~ 2.0MPa R 1/8
GAA501100 φ50 0 ~ 1.0MPa R 1/8 A
(1.5% FS)
GAA501020 φ50 0 ~ 0.2MPa R 1/8
product image
 
PDF catalog Azbil TA- Fluid Control Technology at Its Best General Catalogue
PDF catalog