MODEL NUMBERS & SPECIFICATIONS
MODEL NUMBER | G01-100 | G01-200 | QEV-3303Y | QEV-3304Y | QEV-3306 | QEV-3310 | |
PIPE SIZE | IN,OUT | Rc1/8 | Rc1/4 | Rc3/8 | Rc1/2 | Rc3/4 | Rc1 |
EX | Rc1/4 | Rc1/2 | Rc1 | ||||
FLUID | Filtered Compressed Air | ||||||
MAX. OPERATING PRESSURE | 1.0MPa | ||||||
CRACKING PRESSURE | 0.03MPa | ||||||
AMBIENT TEMPERATURE | 5~60 °C | ||||||
EFFECTIVE AREA (mm²) <Cv value> |
IN-OUT | 37<2.0> | 69<3.7> | 275<14.9> | |||
OUT-EX | 33<1.8> | 82<4.4> | 330<17.8> | ||||
MASS [kg] | 0.1 | 0.35 | 1.0 |
MODEL NUMBERS & SPECIFICATIONS
MODEL NUMBER | J01-100 | J01-200 | CV-3103Y | CV-3104Y | CV-3106 | CV-3110 | |
PIPE SIZE (Port A, B & 0) | Rc1/8 | Rc1/4 | Rc3/8 | Rc1/2 | Rc3/4 | Rc1 | |
FLUID | Filtered Compressed Air | ||||||
MAX. OPERATING PRESSURE | 1.0MPa | ||||||
CRACKING PRESSURE | 0.05MPa | ||||||
AMBIENT TEMPERATURE | 5~60 °C | ||||||
EFFECTIVE AREA (mm²) <Cv value> |
A–0 | 25<1.4> | 28<1.5> | 90<4.9> | 110<5.9> | 250<13.5> | 275<14.9> |
B–0 | 23<1.2> | 28<1.5> | 95<5.1> | 115<6.2> | 305<16.5> | 320<17.3> | |
MASS [kg] | 0.13 | 0.37 | 1.2 | 1.1 |
SPECIFICATIONS
FLUID | Filtered Compressed Air, Non-corrosive Gases. |
MAX. ALLOWABLE PRESSURE | 0.85MPa |
AMBIENT TEMPERATURE | 5~60°C |
OPERATION | Directly spring operated |
TO LOCK ADJUSTING NEEDLE | Snap lock type(by one operation) |
SPECIFICATIONS
FLUID | Filtered Compressed Air, Non-corrosive Gases. |
MAX. ALLOWABLE PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5~60°C |
OPERATION | Directly spring operated |
SPECIFICATIONS
FLUID | Compressed Air, Non-corrosive Gases. |
MAX. ALLOWABLE PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5~60°C |
OPERATION | External pilot operated Diaphragm type |
SPECIFICATIONS
FLUID | Filtered Compressed Air |
MAX. ALLOWABLE PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5~60°C |
OPERATION | Directly spring operated |
MASS [kg] | 0.15(NSV-301) 0.16(NSV-302、NSV-303) 0.18(NSV-304) |
SPECIFICATIONS
MODEL NUMBER | CUV-404 | |||
OPERATION | Electrical | |||
PIPE SIZE | “V” “C” Port | Rc1/2 | ||
“P” Port | Rc1/4 | |||
FLUID | Compressed Air | |||
MAX. ALLOWABLE PRESSURE | 1.0MPa | |||
OPERATING PRESSURE RANGE | 0.25 ~ 0.6MPa | |||
AMBIENT TEMPERATURE | 5 ~ 50°C | |||
RATED VOLTAGE (–15 ~ +10%) |
•AC100V 50/60Hz, 110V 60Hz •AC200V 50/60Hz, 200V 60Hz •DC-24V |
|||
LUBRICANT | Turbine Oil ISO VG 32 or equivalent Recommended | |||
EFFECTIVE AREA | 100mm² | |||
APPROPRIATE CYLINDER BORE SIZE* | max.φ80 (φ100) | |||
LOAD EFFICIENCY OF CYLINDER** | To be less than 40% | |||
MASS [kg] | 1.0 |
* The cylinder bore in ( ) is available under limited conditions
** Included mass of the cylinder’s piston and rod.
SPECIFICATIONS
FLUID | Compressed air filtered with 25μm rated or finer rated filter | |||
OPERATING PRESSURE RANGE | 0.35~0.5MPa | |||
PIPE SIZE | Rc1/8: In & Vacuum Port | |||
AMBIENT TEMPERATURE | 5~50°C | |||
GENERATED VACUUM DEGREE | -0.08MPa or more | Operating pressure at 0.4MPa |
||
SUCTION AIR AMOUNT | 18±1.5dm³/min.(ANR) | |||
AIR CONSUMPTION | 30~40dm³/min.(ANR) | |||
RATED VOLTAGE OF SOLENOID VALVE | •AC-100V 50/60Hz,110V 60Hz •AC-200V 50/60Hz,220V 60Hz •DC-24V |
|||
ALLOWABLE VOLTAGE FLUCTUATION | -15 ~ +10% | |||
TYPE OF SOLENOID VALVE | 2-port, Normally open | |||
ELECTRIC CURRENT OF SOLENOID | 50Hz | 60Hz | ||
HOLDING (Inrush) ELECTRIC CURRENT |
AC-100V | 0.015 (0.018)A | 0.014 (0.016)A | |
AC-200V | 0.011 (0.013)A | 0.009 (0.011)A | ||
DC-24V | 0.070A |
SPECIFICATIONS OF VACUUM SENSOR
SUPPLY VOLTAGE | 12 ~ 24V DC (20mA max.) |
SETTING OF VACUUM DEGREE | -400 ±40mmHg (set at factory) |
OUTPUT & CAPACITY | NPN open collector, 80mA max. (30V) |
OPERATION LAMP | Red LED (turned on at and over set vacuum degree) |
(lighted on more than vacuum setting)