azbil

HOME > TOP > PRODUCTS > AUXILIARY CIRCUIT COMPONENTS

QUICK EXHAUST VALVE

G01 & QEV-3300 (Y) SERIES

G01 & QEV-3300 (Y) SERIES

MODEL NUMBERS & SPECIFICATIONS

MODEL NUMBER G01-100 G01-200 QEV-3303Y QEV-3304Y QEV-3306 QEV-3110
PIPE SIZE  IN,OUT Rc1/8 Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1
 EX Rc1/4 Rc1/2 Rc1
FLUID Filtered Compressed Air
MAX. OPERATING PRESSURE 1.0MPa
CRACKING PRESSURE 0.03MPa
AMBIENT TEMPERATURE 5~60 °C
EFFECTIVE AREA
(mm²) <Cv value>
IN-OUT 37<2.0> 69<3.7> 275<14.9>
OUT-EX 33<1.8> 82<4.4> 330<17.8>
MASS [kg] 0.1 0.35 1.0

SHUTTLE VALVE

J01 & CV-3100 (Y) SERIES

J01 & CV-3100 (Y) SERIES

MODEL NUMBERS & SPECIFICATIONS

MODEL NUMBER J01-100 J01-200 CV-3103Y CV-3104Y CV-3106 CV-3110
PIPE SIZE (Port A, B & 0) Rc1/8 Rc1/4 Rc3/8 Rc1/2 Rc3/4 Rc1
FLUID Filtered Compressed Air
MAX. OPERATING PRESSURE 1.0MPa
CRACKING PRESSURE 0.05MPa
AMBIENT TEMPERATURE 5~60 °C
EFFECTIVE AREA
(mm²) <Cv value>
A–0 25<1.4> 28<1.5> 90<4.9> 110<5.9> 250<13.5> 275<14.9>
B–0 23<1.2> 28<1.5> 95<5.1> 115<6.2> 305<16.5> 320<17.3>
MASS [kg] 0.13 0.37 1.2 1.1

RELIEF VALVE

V31 SERIES

V31 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air, Non-corrosive Gases.
MAX. ALLOWABLE PRESSURE 0.85MPa
AMBIENT TEMPERATURE 5~60°C
OPERATION Directly spring operated
TO LOCK ADJUSTING NEEDLE Snap lock type(by one operation)

NSV-200 SERIES

NSV-200 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air, Non-corrosive Gases.
MAX. ALLOWABLE PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5~60°C
OPERATION Directly spring operated

NSV-500 SERIES

NSV-500 SERIES

SPECIFICATIONS

FLUID Compressed Air, Non-corrosive Gases.
MAX. ALLOWABLE PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5~60°C
OPERATION External pilot operated Diaphragm type

NSV-300 SERIES

NSV-300 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
MAX. ALLOWABLE PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5~60°C
OPERATION Directly spring operated
MASS [kg]

0.15(NSV-301)   0.16(NSV-302、NSV-303)

0.18(NSV-304)

CUSHION VALVE

CUV-400 SERIES

CUV-400 SERIES

SPECIFICATIONS

MODEL NUMBER CUV-404
OPERATION Electrical
PIPE SIZE “V” “C” Port Rc1/2
“P” Port Rc1/4
FLUID Compressed Air
MAX. ALLOWABLE PRESSURE 1.0MPa
OPERATING PRESSURE RANGE 0.25 ~ 0.6MPa
AMBIENT TEMPERATURE 5 ~ 50°C
RATED VOLTAGE
(–15 ~ +10%)

•AC100V 50/60Hz, 110V 60Hz

•AC200V 50/60Hz, 200V 60Hz

•DC-24V
LUBRICANT Turbine Oil ISO VG 32 or equivalent Recommended
EFFECTIVE AREA 100mm²
APPROPRIATE CYLINDER BORE SIZE* max.φ80 (φ100)
LOAD EFFICIENCY OF CYLINDER** To be less than 40%
MASS [kg] 1.0

* The cylinder bore in ( ) is available under limited conditions

** Included mass of the cylinder’s piston and rod.


EJECTOR UNIT FOR VACUUM GENERATOR

VC1-101 SERIES

VC1-101 SERIES

SPECIFICATIONS

FLUID Compressed air filtered with 25μm rated or finer rated filter
OPERATING PRESSURE RANGE 0.35~0.5MPa
PIPE SIZE Rc1/8: In & Vacuum Port
AMBIENT TEMPERATURE 5~50°C
GENERATED VACUUM DEGREE -0.08MPa or more

Operating

pressure

at 0.4MPa
SUCTION AIR AMOUNT 18±1.5dm³/min.(ANR)
AIR CONSUMPTION 30~40dm³/min.(ANR)
RATED VOLTAGE OF SOLENOID VALVE

•AC-100V 50/60Hz,110V 60Hz

•AC-200V 50/60Hz,220V 60Hz

•DC-24V
ALLOWABLE VOLTAGE FLUCTUATION -15 ~ +10%
TYPE OF SOLENOID VALVE 2-port, Normally open
ELECTRIC CURRENT OF SOLENOID 50Hz 60Hz
HOLDING (Inrush)
ELECTRIC
CURRENT
AC-100V 0.015 (0.018)A 0.014 (0.016)A
AC-200V 0.011 (0.013)A 0.009 (0.011)A
DC-24V 0.070A

SPECIFICATIONS OF VACUUM SENSOR

SUPPLY VOLTAGE 12 ~ 24V DC (20mA max.)
SETTING OF VACUUM DEGREE -400 ±40mmHg (set at factory)
OUTPUT & CAPACITY NPN open collector, 80mA max. (30V)
OPERATION LAMP Red LED
(turned on at and over set vacuum degree)

(lighted on more than vacuum setting)