5-PORT SPOOL OPERATED MASTER VALVE

MVM-495 SERIES

MVM-495 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.2 ~1.0MPa
  Main pressure
range
0.2 ~1.0MPa
Pilot pressure
range
Same to pressure of main valve or higher.
AMBIENT TEMPERATURE 5 ~ 60°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.


MVM-492 SERIES 1/4B base

MVM-492 SERIES 1/4B base

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.2 ~1.0MPa
  Main pressure
range
0.2 ~1.0MPa
Pilot pressure
range
Same to pressure of main valve or higher.
AMBIENT TEMPERATURE 5 ~ 60°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.


524-M SERIES 1/2B base

524-M SERIES 1/2B base

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0 ~1.0MPa
  Main pressure
range
0 ~0.2MPa 0.2 ~1.0MPa
Pilot pressure
range
0.2 ~0.3MPa

Same to pressure of main

valve or higher.

AMBIENT TEMPERATURE 5 ~ 60°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.


MVM-491 SERIES 1B base

MVM-491 SERIES 1B base

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.15 ~1.0MPa
  Main pressure
range
0.15 ~1.0MPa
Pilot pressure
range
Same to pressure of main valve or higher.
AMBIENT TEMPERATURE 5 ~ 60°C
LUBRICANTS ISO VG32 turbine oil, or equivalent oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.


MVM-491 SERIES 1-1/2B base

MVM-491 SERIES 1-1/2B base

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.15 ~1.0MPa
  Main pressure
range
0.15 ~1.0MPa
Pilot pressure
range
Same to pressure of main valve or higher.
AMBIENT TEMPERATURE 5 ~ 60°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.


4-PORT POPPET OPERATED MASTER VALVE

460 Super Poppet SERIES (2-Position)

460 Super Poppet series (2-Position)

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.05 ~1.0MPa
  Main pressure
range
0.05 ~ 0.15MPa 0.15 ~ 1.0MPa
Pilot pressure
range
0.15 ~ 0.3MPa Same to pressure of
main valve or higher.
AMBIENT TEMPERATURE 5 ~ 60°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.

* Pilot pressure must not exceed 1.0MPa.


460 Super Poppet SERIES (3-Position)

460 Super Poppet series (3-Position)

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.05 ~1.0MPa
  Main pressure
range
0.05 ~0.15MPa 0.15 ~ 1.0MPa
Pilot pressure
range
0.15 ~ 0.3MPa Same to pressure of
main valve or higher.
AMBIENT TEMPERATURE 5 ~ 60°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.


3-PORT POPPET OPERATED MASTER VALVE

360 Super Poppet SERIES

360 Super Poppet SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.05 ~1.0MPa
  Main pressure
range
0.05 ~ 0.15MPa 0.15 ~ 1.0MPa
Pilot pressure
range
0.15 ~ 0.3MPa Same to pressure of
main valve or higher.
AMBIENT TEMPERATURE 5 ~ 60°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.

* Pilot pressure must not exceed 1.0MPa.


360 Super Poppet SERIES (High-Low Pressure change)

360 Super Poppet SERIES (High-Low Pressure change)

SPECIFICATIONS

FLUID Filtered Compressed Air
SERVICING
PRESSURE
Master valve
pressure range*
Higher Pressure side (IN)
0.05 ~1.0MPa
Lower Pressure side (EX)
0 ~ 0.85MPa
Pilot air pressure
setting of pilot air
pressure*
P = Higher pressure side (IN) +
0 ~ 0.2MPa
P = Lower pressure side (EX) +
0.15MPa
AMBIENT TEMPERATURE 5 ~ 60°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* High side pressure (=IN PORT), Lower side pressure (=EX PORT)

* Pilot air pressure must be lower than 1.0MPa (=10kgf/cm²).


392 SERIES (FOR COMPRESSED AIR & VACUUM)

392 SERIES (FOR COMPRESSED AIR & VACUUM)

SPECIFICATIONS

FLUID Filtered Compressed Air Vacuum
OPERATING PRESSURE 0 ~ 0.7MPa – 0.1 ~ 0MPa
AMBIENT TEMPERATURE 5 ~ 50°C
LUBRICANTS Can use without lubrication
MANUAL OPERATION Manual push button / Non-lock type
RATED VOLTAGE ● AC-100V 50/60Hz, 110V 60Hz
● AC-200V 50/60Hz, 220V 60Hz
● DC-24V
VOLTAGE ALLOWANCE -15 ~ 10%
INSULATION GRADE Class B

2-PORT POPPET OPERATED MASTER VALVE

260 Super Poppet SERIES

260 Super Poppet SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0.05 ~1.0MPa
  Main pressure
range
0.05 ~ 0.15MPa 0.15 ~ 1.0MPa
Pilot pressure
range
0.15 ~ 0.3MPa Same to pressure of
main valve or higher.
AMBIENT TEMPERATURE 5 ~ 60°C
PROOF PRESSURE 1.6MPa
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.

* Pilot pressure must not exceed 1.0MPa.


5-PORT PILOT VALVE

POV-4000, 3000 SERIES

POV-4000, 3000 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0 ~ 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.

HAND VALVE

DV-4100 SERIES

DV-4100 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air
OPERATING PRESSURE 0 ~ 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
LUBRICANTS ISO VG32 turbine oil, or equivalent
oil is recommended.
HANDLE ROTATION
ANGLE
At actuated position, rotation angle to clock-
with or anticlockwise direction is 45°

 
PDF catalog Azbil TA- Fluid Control Technology at Its Best General Catalogue
PDF catalog