azbil

HOME > TOP > PRODUCTS > PRESSURE SWITCHES AIR LIMITERS AIR FILTERS

PRESSURE SWITCH

PSD-101 SERIES

PSD-101 SERIES

SPECIFICATIONS

FLUID Filtered Compressed Air, Non-corrosive Gases
MAX. ALLOWABLE PRESSURE 1.0MPa
AMBIENT TEMPERATURE –10°C ~ 50°C
CONTACT POINT 1c
CONTACT POINT CAPACITY
(Resistance Load)
High sensitive type • 15A/AC 125V. 250V
• 2A/DC 24V
Small electric current type
(For programable controller)
• 1 ~ 100mA/AC 100V
• 3 ~ 100mA/DC 24V
REPEATABILITY Standard type 0.003MPa
For K5, K1 0.002MPa
PIPE SIZE Pressure air sensing port Rc 1/4
Gauge port: Rc 1/8
MASS (kg) 1.5

P02-200 SERIES

P02-200 SERIES

SPECIFICATIONS

FLUID Compressed Air and Non-corrosive gases
WITHSTAND PRESSURE 0.7MPa
PORT SIZE R 1/4 (Male)
AMBIENT TEMPERATURE 5 ~ 50°C (Humidity: 95% max.)
SPECIFYING SET
PRESSURE RANGE
0.03 ~ 0.37 MPa
(OFF setting: setting pressure of switch off)
REPEATABILITY Within 0.013MPa against the set pressure (@20°C)
CONTACT POINT TYPE 1c (0.1A /125V AC, 0.1A / 30V DC)
MASS(g) 30

AIR LIMITER

S51 SERIES

S51 SERIES

SPECIFICATIONS

MODEL NO. S51-1※1-※0※※(Std.) S51-1※1-※3※※
FLUID Filtered Clean Compressed Air,
(by 5μm rated filter),No Oiliness
PIPE SIZE Rc1/8 (Both IN port and OUT (Sensing) port
AMBIENT TEMPERATURE 5 ~ 50°C
METERING ORIFICE φ0.7mm (Standard) φ1.2mm
SENSING GAP RANGE 0.01 ~ 0.15mm 0.16 ~ 0.3mm 0.01 ~ 0.15mm
  SUPPLY PRESSURE
FOR IN PORT
0.2MPa 0.3MPa *2 0.2MPa
SENSING NOZZLE DIA.*1 φ1mm φ1.5mm
SENSING ACCURACY ±0.01mm ±0.02mm ±0.03mm
AIR CONSUMPTION 10dm³/min (ANR) 13dm³/min (ANR) 30dm³/min (ANR)
CONTACT TYPE OF SWITCH 1c (Single Pole, Double Throw)
PROTECTION SPECIFICATION IP-67
ELECTRICAL CONNECTION G1/2 Conduit port (Std.), or CAPCON or CORDLOCK added
OUT PORT SENSING TUBING φ4mm I.D. tubing, max. 4m length
AVAILABLE RANGE OF
ELECTRIC CURRENT
(TYPE OF SWITCH FOR
OUTPUT)
○ Small electric current type (for programable controllers);
• 1 ~ 100mA / AC100V or DC24V
○ High sensitive type;
• 30 ~ 100mA /AC100V
• 20 ~ 100mA /AC200V
• 35 ~ 100mA /DC24V
PILOT LAMP & DARKNESS
LEAKAGE CURRENT
○ Neon Lamp /0.6mA: for use on models rated AC100 /200V
○ LED Lamp /0.85mA: for use on models rated DC24V
MASS(kg) 0.5

*1.Use one sensing nozzle for one S51 Air limiter unit.

*2.Economiter is impossible to install in the system of 0.3MPa supply pressure.


S51 SERIES(Stacked with Economiter)

S51 SERIES(Stacked with Economiter)

SPECIFICATIONS

PIPE SIZE Rc1/4 for IN port, Rc1/8 for sensing port
FLUID Compressed air filtered by 5μm filter
element (No oiliness)
OPERATING PRESSURE 0.2MPa ……Supply pressure
AMBIENT TEMPERATURE 5 ~ 50°C
ELECTRICAL CONNECTIONS Economiter: MVS-214-02KS-07
• DIN type Pg 11
(for cable dia. of 6 ~ 10mm)
Air limiter: S51 series
•G1/2 for conduit (Std.)
Optional capcon or cordlock available
MAX. STACKING Up to 3 Air limiter units
MASS(kg) 1.93kg /with 3 units
1.43kg /2 units
0.93kg /1 unit
FOR ECONOMITER  
  RATED VOLTAGE • AC 100V 50/60Hz, 110V 60Hz
• AC 200V 50/60Hz, 220V 60Hz
• DC 24V
VOLTAGE ALLOWANCE –15 ~ +10%
INSULATION CLASS B
SOLENOID
HOLDING
CURRENT
(INRUSH)
50Hz 60Hz
AC 100V 0.102 (0.165) A 0.079 (0.140)A
AC 200V 0.049 (0.080) A 0.039 (0.068)A
DC 24V 0.27A
FOR AIR LIMITER  
  TYPE OF SWITCH Small current type High sensitive type
CURRENT
CAPACITY
OF SWITCH
AC 100V 1 ~ 100mA 30 ~ 100mA
AC 200V NA 20 ~ 100mA
DC 24V 1 ~ 100mA 35 ~ 100mA

S51 Manifold Panel

S51 Manifold Panel

SPECIFICATIONS

FLUID Filtered (5μm) Compressed Air
MAX. INLET PRESSURE 1.0MPa
OPERATING PRESSURE 0.2MPa
PIPE SIZE Rc1/4 (IN port), Rc1/8 (Sensing port)
AMBIENT TEMPERATURE 5 ~ 50°C
ECONOMITER AC100V 50/60Hz, AC110V 60Hz
RATED VOLTAGE FOR
AIR LIMITER
AC100V (NEON), AC200V (NEON)
DC24V (LED, red)

AOL-112 SERIES

AOL-112 SERIES

SPECIFICATIONS

FLUID Filtered Clean Compressed Air (by 5μm rated filter), No oiliness
PIPE SIZE Rc1/4; Both IN / Supply port and OUT / Sensing port
AMBIENT TEMPERATURE 5 ~ 60°C
OPERATING PRESSURE 0.05 ~ 0.2MPa
SENSING GAP RANGE 0.01 ~ 0.6mm
SENSING ACCURACY ±0.01mm for Gap: 0.01 ~ 0.2mm,
±0.03 for gap: 0.2mm ~
SENSING PRESSURE RANGE 0.01 ~ 0.1MPa Adjustable
CONTACT TYPE OF SWITCH 1c (Single Pole, Double Throw)
AVAILABLE ELECTRIC
CURRENT CAPACITY OF
OUTPUT SWITCH
Small electric current
type switch(for programable
controller)
• 1 ~ 100mA /AC100V
• 3 ~ 100mA /DC24V
High sensitive type switch • 30 ~ 100mA /AC100V
• 20 ~ 100mA /AC200V
• 35 ~ 100mA /DC24V
OPERATION PILOT LAMP Option (Neon lamp or LED lamp / clear, green or red)
MASS(kg) 1.9

AOL-112 Manifold Panel

AOL-112 Manifold Panel

SPECIFICATIONS

FLUID Filtered (5μm) Compressed Air
MAX. INLET PRESSURE MAX. INLET PRESSURE
OPERATING PRESSURE 0.2MPa max.
PIPE SIZE Rc1/4 for IN port, Rc1/8 for Sensing port
AMBIENT TEMPERATURE 5 ~ 50°C
RATED VOLTAGES
OF ECONOMITER
AC100V, AC200V or DC24V
(Allowable Fluctuation: –5 ~ +10%)
AIR LIMITER  
  SENSING GAP 0.01 ~ 0.2 (±0.01) mm
0.2 ~ 0.6 (±0.03) mm
PILOT LAMP
& RATED VOLTAGE
Neon Lamp for AC100V /AC200V
LED Lamp for DC24V
OUTPUT OF SWITCH max. 100mA / capacity, 1c type contact

◎ See details at pages of each unit.

① Switch of Air limiter
NIL High sensitive type
A Small electric current type
② Lamps & Voltage of Air limiter
Color Clear Green Red
Volt
AC100V T1 G1 R1
AC200V T2 G2 R2
DC24V T3 G3 R3
③ Number (N) of AOL-112 units for Manifold
1 1
2 2
3 3
④ Rated Voltage of Economitor
1 AC 100V
2 AC 200V
3 DC 24V

Small electric current type Air limiter with pilot lamp is only available AC100V and DC24V


EXCLUSIVE PURGE VALVE FOR AIR LIMITER

MVS-214-02S-07

MVS-214-02S-07

SPECIFICATIONS

FLUID Filtered Compressed Air by 5μm Filter
Element (No oiliness)
OPERATING PRESSURE 0.2MPa max.
AMBIENT TEMPERATURE 5 ~ 50°C
EFFECTIVE AREA 5mm²
PURGING FLOW RANGE 0.6 ~ 1.6dm³/min. (ANR)
(Equivalent to pressure adjustment of
built-in regulator: 0.007 ~ 0.05MPa)
MANUAL OPERATOR Lever, 2 Position
RATED VOLTAGE • AC 100V 50/60Hz, 110V 60Hz
• AC 200V 50/60Hz, 220V 60Hz
• DC 24V
ELECTRIC CONNECTOR • DIN: Pg 11
• with Pilot Lamp & Surge Suppresser
VOLTAGE ALLOWANCE –15 ~ +10%
INSULATION CLASS B
SOLENOID
HOLDING
CURRENT
(Inrush)
50Hz 60Hz
AC 100V 0.102 (0.165) A 0.079 (0.140) A
AC 200V 0.049 (0.080) A 0.039 (0.068) A
DC 24V 0.27A
MASS(kg) 0.45

* This unit is impossible to be combined with Air Limiter operated by supply pressure of 0.3MPa


AIR FILTER

NAF-500 SERIES

NAF-500 SERIES

SPECIFICATIONS

FLUID Compressed Air
MAX. INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
FILTER ELEMENT 74μm
DRAINAGE Manual or Automatic

* Minimum operating pressure for Automatic drain model is 0.1MPa.


NAF-600 SERIES

NAF-600 SERIES

SPECIFICATIONS

FLUID Compressed Air
MAX. INLET PRESSURE 1.0MPa
AMBIENT TEMPERATURE 5 ~ 60°C
FILTER ELEMENT 74μm (Std.), 25μm or 5μm
DRAINAGE Manual or Automatic
BOWL Transparent Polycarbonate Bowl with Bowl
Guard, or Metal Bowl

SELF-DRAIN UNIT

SDU-200, 300XL SERIES

SDU-200, 300XL SERIES

MODEL NOs. & SPECIFICATION

MODEL NUMBERS SDU-202 SDU-306XL
PIPE SIZES DRAIN INLET Rc1/4 Rc3/4
DRAIN OUTLET Rc1/8 Rc1/2
OPERATING PRESSURE 0.1 ~ 1.0MPa 0.05 ~ 0.7MPa
AMBIENT TEMPERATURE 5 ~ 60°C 5 ~ 50°C
DRAINAGE CAPACITY 3.5cm³ @0.5MPa 200cm³ @0.7MPa
RESERVOIR Metal Bowl Metal Cylinder with
level gauge
DRAINAGE OPERATION Float & Air Pressure Float & Solenoid Valve
MASS(kg) 0.44 5.3
SOLENOID • AC 100V 50/60Hz,
110V 60Hz
• AC 200V 50/60Hz,
220V 60Hz
  RATED VOLTAGE
VOLTAGE ALLOWANCE –15 ~ +10%
INSULATION Class B
ELECTRIC CURRENT
OF SOLENOID:
  50Hz 60Hz
HOLDING (INRUSH) AC 100V 0.104A
(0.126A)
0.084A
(0.10A)
AC 200V 0.05A
(0.06A)
0.041A
(0.05A)

*1. SDU-306XL is required to specify operating voltage at end of model no.

*2. SDU-202 with bracket can specify by adding B at end of model no.


 
PDF catalog Azbil TA- Fluid Control Technology at Its Best General Catalogue
PDF catalog
 

©2000- Azbil TA Co., Ltd. All rights reserved.