SPECIFICATIONS
FLUID | Filtered Compressed Air, Non-corrosive Gases | |
MAX. ALLOWABLE PRESSURE | 1.0MPa | |
AMBIENT TEMPERATURE | –10°C ~ 50°C | |
CONTACT POINT | 1c | |
CONTACT POINT CAPACITY (Resistance Load) |
High sensitive type | • 15A/AC 125V. 250V • 2A/DC 24V |
Small electric current type (For programable controller) |
• 1 ~ 100mA/AC 100V • 3 ~ 100mA/DC 24V |
|
REPEATABILITY | Standard type | 0.003MPa |
For K5, K1 | 0.002MPa | |
PIPE SIZE | Pressure air sensing port Rc 1/4 Gauge port: Rc 1/8 |
|
MASS (kg) | 1.5 |
SPECIFICATIONS
FLUID | Compressed Air and Non-corrosive gases | |
WITHSTAND PRESSURE | 0.7MPa | |
PORT SIZE | R 1/4 (Male) | |
AMBIENT TEMPERATURE | 5 ~ 50°C (Humidity: 95% max.) | |
SPECIFYING SET PRESSURE RANGE |
0.03 ~ 0.37 MPa (OFF setting: setting pressure of switch off) |
|
REPEATABILITY | Within 0.013MPa against the set pressure (@20°C) | |
CONTACT POINT TYPE | 1c (0.1A /125V AC, 0.1A / 30V DC) | |
MASS(g) | 30 |
S51 SERIES |
S51 SERIES(Stacked with Economiter) |
S51 Manifold Panel |
AOL-112 SERIES |
AOL-112 Manifold Panel |
SPECIFICATIONS
MODEL NO. | S51-1※1-※0※※(Std.) | S51-1※1-※3※※ | ||
FLUID | Filtered Clean Compressed Air, (by 5μm rated filter),No Oiliness |
|||
PIPE SIZE | Rc1/8 (Both IN port and OUT (Sensing) port | |||
AMBIENT TEMPERATURE | 5 ~ 50°C | |||
METERING ORIFICE | φ0.7mm (Standard) | φ1.2mm | ||
SENSING GAP RANGE | 0.01 ~ 0.15mm | 0.16 ~ 0.3mm | 0.01 ~ 0.15mm | |
SUPPLY PRESSURE FOR IN PORT |
0.2MPa | 0.3MPa *2 | 0.2MPa | |
SENSING NOZZLE DIA.*1 | φ1mm | φ1.5mm | ||
SENSING ACCURACY | ±0.01mm | ±0.02mm | ±0.03mm | |
AIR CONSUMPTION | 10dm³/min (ANR) | 13dm³/min (ANR) | 30dm³/min (ANR) | |
CONTACT TYPE OF SWITCH | 1c (Single Pole, Double Throw) | |||
PROTECTION SPECIFICATION | IP-67 | |||
ELECTRICAL CONNECTION | G1/2 Conduit port (Std.), or CAPCON or CORDLOCK added | |||
OUT PORT SENSING TUBING | φ4mm I.D. tubing, max. 4m length | |||
AVAILABLE RANGE OF ELECTRIC CURRENT (TYPE OF SWITCH FOR OUTPUT) |
○ Small electric current type (for programable controllers); • 1 ~ 100mA / AC100V or DC24V ○ High sensitive type; • 30 ~ 100mA /AC100V • 20 ~ 100mA /AC200V • 35 ~ 100mA /DC24V |
|||
PILOT LAMP & DARKNESS LEAKAGE CURRENT |
○ Neon Lamp /0.6mA: for use on models rated AC100 /200V ○ LED Lamp /0.85mA: for use on models rated DC24V |
|||
MASS(kg) | 0.5 |
*1.Use one sensing nozzle for one S51 Air limiter unit.
*2.Economiter is impossible to install in the system of 0.3MPa supply pressure.
SPECIFICATIONS
PIPE SIZE | Rc1/4 for IN port, Rc1/8 for sensing port | |||
FLUID | Compressed air filtered by 5μm filter element (No oiliness) |
|||
OPERATING PRESSURE | 0.2MPa ……Supply pressure | |||
AMBIENT TEMPERATURE | 5 ~ 50°C | |||
ELECTRICAL CONNECTIONS | Economiter: MVS-214-02KS-07 • DIN type Pg 11 (for cable dia. of 6 ~ 10mm) Air limiter: S51 series •G1/2 for conduit (Std.) Optional capcon or cordlock available |
|||
MAX. STACKING | Up to 3 Air limiter units | |||
MASS(kg) | 1.93kg /with 3 units 1.43kg /2 units 0.93kg /1 unit |
|||
FOR ECONOMITER | ||||
RATED VOLTAGE | • AC 100V 50/60Hz, 110V 60Hz • AC 200V 50/60Hz, 220V 60Hz • DC 24V |
|||
VOLTAGE ALLOWANCE | –15 ~ +10% | |||
INSULATION CLASS | B | |||
SOLENOID HOLDING CURRENT (INRUSH) |
― | 50Hz | 60Hz | |
AC 100V | 0.102 (0.165) A | 0.079 (0.140)A | ||
AC 200V | 0.049 (0.080) A | 0.039 (0.068)A | ||
DC 24V | 0.27A | |||
FOR AIR LIMITER | ||||
TYPE OF SWITCH | Small current type | High sensitive type | ||
CURRENT CAPACITY OF SWITCH |
AC 100V | 1 ~ 100mA | 30 ~ 100mA | |
AC 200V | NA | 20 ~ 100mA | ||
DC 24V | 1 ~ 100mA | 35 ~ 100mA |
SPECIFICATIONS
FLUID | Filtered (5μm) Compressed Air |
MAX. INLET PRESSURE | 1.0MPa |
OPERATING PRESSURE | 0.2MPa |
PIPE SIZE | Rc1/4 (IN port), Rc1/8 (Sensing port) |
AMBIENT TEMPERATURE | 5 ~ 50°C |
ECONOMITER | AC100V 50/60Hz, AC110V 60Hz |
RATED VOLTAGE FOR AIR LIMITER |
AC100V (NEON), AC200V (NEON) DC24V (LED, red) |
SPECIFICATIONS
FLUID | Filtered Clean Compressed Air (by 5μm rated filter), No oiliness | |
PIPE SIZE | Rc1/4; Both IN / Supply port and OUT / Sensing port | |
AMBIENT TEMPERATURE | 5 ~ 60°C | |
OPERATING PRESSURE | 0.05 ~ 0.2MPa | |
SENSING GAP RANGE | 0.01 ~ 0.6mm | |
SENSING ACCURACY | ±0.01mm for Gap: 0.01 ~ 0.2mm, ±0.03 for gap: 0.2mm ~ |
|
SENSING PRESSURE RANGE | 0.01 ~ 0.1MPa Adjustable | |
CONTACT TYPE OF SWITCH | 1c (Single Pole, Double Throw) | |
AVAILABLE ELECTRIC CURRENT CAPACITY OF OUTPUT SWITCH |
Small electric current type switch(for programable controller) |
• 1 ~ 100mA /AC100V • 3 ~ 100mA /DC24V |
High sensitive type switch | • 30 ~ 100mA /AC100V • 20 ~ 100mA /AC200V • 35 ~ 100mA /DC24V |
|
OPERATION PILOT LAMP | Option (Neon lamp or LED lamp / clear, green or red) | |
MASS(kg) | 1.9 |
SPECIFICATIONS
FLUID | Filtered (5μm) Compressed Air | |
MAX. INLET PRESSURE | MAX. INLET PRESSURE | |
OPERATING PRESSURE | 0.2MPa max. | |
PIPE SIZE | Rc1/4 for IN port, Rc1/8 for Sensing port | |
AMBIENT TEMPERATURE | 5 ~ 50°C | |
RATED VOLTAGES OF ECONOMITER |
AC100V, AC200V or DC24V (Allowable Fluctuation: –5 ~ +10%) |
|
AIR LIMITER | ||
SENSING GAP | 0.01 ~ 0.2 (±0.01) mm 0.2 ~ 0.6 (±0.03) mm |
|
PILOT LAMP & RATED VOLTAGE |
Neon Lamp for AC100V /AC200V LED Lamp for DC24V |
|
OUTPUT OF SWITCH | max. 100mA / capacity, 1c type contact |
◎ See details at pages of each unit.
① Switch of Air limiter | |
NIL | High sensitive type |
A | Small electric current type |
② Lamps & Voltage of Air limiter | |||
Color | Clear | Green | Red |
Volt | |||
AC100V | T1 | G1 | R1 |
AC200V | T2 | G2 | R2 |
DC24V | T3 | G3 | R3 |
③ Number (N) of AOL-112 units for Manifold | |
1 | 1 |
2 | 2 |
3 | 3 |
④ Rated Voltage of Economitor | |
1 | AC 100V |
2 | AC 200V |
3 | DC 24V |
Small electric current type Air limiter with pilot lamp is only available AC100V and DC24V
SPECIFICATIONS
FLUID | Filtered Compressed Air by 5μm Filter Element (No oiliness) |
||
OPERATING PRESSURE | 0.2MPa max. | ||
AMBIENT TEMPERATURE | 5 ~ 50°C | ||
EFFECTIVE AREA | 5mm² | ||
PURGING FLOW RANGE | 0.6 ~ 1.6dm³/min. (ANR) (Equivalent to pressure adjustment of built-in regulator: 0.007 ~ 0.05MPa) |
||
MANUAL OPERATOR | Lever, 2 Position | ||
RATED VOLTAGE | • AC 100V 50/60Hz, 110V 60Hz • AC 200V 50/60Hz, 220V 60Hz • DC 24V |
||
ELECTRIC CONNECTOR | • DIN: Pg 11 • with Pilot Lamp & Surge Suppresser |
||
VOLTAGE ALLOWANCE | –15 ~ +10% | ||
INSULATION CLASS | B | ||
SOLENOID HOLDING CURRENT (Inrush) |
― | 50Hz | 60Hz |
AC 100V | 0.102 (0.165) A | 0.079 (0.140) A | |
AC 200V | 0.049 (0.080) A | 0.039 (0.068) A | |
DC 24V | 0.27A | ||
MASS(kg) | 0.45 |
* This unit is impossible to be combined with Air Limiter operated by supply pressure of 0.3MPa
SPECIFICATIONS
FLUID | Compressed Air |
MAX. INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
FILTER ELEMENT | 74μm |
DRAINAGE | Manual or Automatic |
* Minimum operating pressure for Automatic drain model is 0.1MPa.
SPECIFICATIONS
FLUID | Compressed Air |
MAX. INLET PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
FILTER ELEMENT | 74μm (Std.), 25μm or 5μm |
DRAINAGE | Manual or Automatic |
BOWL | Transparent Polycarbonate Bowl with Bowl Guard, or Metal Bowl |
MODEL NOs. & SPECIFICATION
MODEL NUMBERS | SDU-202 | SDU-306XL | ||
PIPE SIZES | DRAIN INLET | Rc1/4 | Rc3/4 | |
DRAIN OUTLET | Rc1/8 | Rc1/2 | ||
OPERATING PRESSURE | 0.1 ~ 1.0MPa | 0.05 ~ 0.7MPa | ||
AMBIENT TEMPERATURE | 5 ~ 60°C | 5 ~ 50°C | ||
DRAINAGE CAPACITY | 3.5cm³ @0.5MPa | 200cm³ @0.7MPa | ||
RESERVOIR | Metal Bowl | Metal Cylinder with level gauge |
||
DRAINAGE OPERATION | Float & Air Pressure | Float & Solenoid Valve | ||
MASS(kg) | 0.44 | 5.3 | ||
SOLENOID | ― | • AC 100V 50/60Hz, 110V 60Hz • AC 200V 50/60Hz, 220V 60Hz |
||
RATED VOLTAGE | ||||
VOLTAGE ALLOWANCE | ― | –15 ~ +10% | ||
INSULATION | ― | Class B | ||
ELECTRIC CURRENT OF SOLENOID: |
50Hz | 60Hz | ||
HOLDING (INRUSH) | AC 100V | 0.104A (0.126A) |
0.084A (0.10A) |
|
AC 200V | 0.05A (0.06A) |
0.041A (0.05A) |
*1. SDU-306XL is required to specify operating voltage at end of model no.
*2. SDU-202 with bracket can specify by adding B at end of model no.