PRODUCTSSEMI DRY MACHINING LUBRICATION UNITS

External Water-Oil Supply Lubrication Unit

Model No. MW2-2_1

Model No. MW2-2_1
  • Incorporates technologies and abundant experience that Azbil TA Co., Ltd. has accumulated in relation to the MQL semi-dry system (lubrication system using the minimum amount of oil).
  • Easily applies semi-dry machining to steel materials that generate a large amount of heat using water particles with a high cooling effect and a tiny amount of mist.
  • Reduces the amount of cutting oil used.
    Reduces the effort involved in washing workpieces and improves the work environment.

Standard specifications

Operating fluid Air Clean compressed air
Oil Oil specifically for water mist recommended by the cutting oil manufacturer (antirust agent added)
Water Tap water
IN side supply pressure 0.3-1.0 MPa
Ambient temperature 5-40°C
Pipe connection threads Air IN Rc1/4
Air OUT Tube coupling with an outer diameter of Ø8
Oil OUT Tube coupling with an outer diameter of Ø4
Water OUT Tube coupling with an outer diameter of Ø6
Setting range of the number of shots Oil pump 1 to 60 shots/min (0.05 cm³/shot)
Water pump 1 to 200 shots/min (0.1 cm³/shot)
Tank capacity Oil tank 3.0 dm³
Water tank 10 dm³ (effective capacity)
Power consumption Approx. 40 W (with ratings of AC 100 V, 50/60 Hz)
Weight Approx. 38 kg (dry weight)

Model No.

MW2 - 2 0 1 - 1 0 7 0
Product name [1] [2] [3] [4]

[1]Number of pumps

0 Single pump
2 Twin pump

[2]Rated voltage (oil pump/air two-way valve)

1 AC 100 V
2 AC 200 V
3 DC 24 V

Notes:

  • The rated voltage of all the water pumps is AC 100 to 240 V.

[3]Accessories

0 No accessories
1 Includes oil and water lower limit level switches
2 Includes oil and water discharge monitoring
3 Includes oil and water lower limit level switches and oil and water discharge monitoring
4 Includes pressure switch
5 Includes pressure switch and oil and water lower limit level switches
6 Includes pressure switch and oil and water discharge monitoring
7 Includes pressure switch, oil and water lower limit level switches, and oil and water discharge monitoring
A Includes automatic water supply
B Includes automatic water and oil supplies
C Includes automatic water supply and oil and water discharge monitoring
D Includes automatic water and oil supplies and oil and water discharge monitoring
E Includes automatic water supply and pressure switch
F Includes automatic water and oil supplies and pressure switch
G Includes automatic water supply, oil and water discharge monitoring, and pressure switch
H Includes automatic water and oil supplies, oil and water discharge monitoring, and pressure switch

[4]Includes cradle with casters

0 No
1 Yes
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS