Filter
Model No. NAF-6_ _
- Swirls air with the louver and deflector to remove drain and debris.
- Achieves a large flow rate with a small pressure drop.
- Ensures a low maintenance frequency.
Standard specifications
| Operating fluid |
Compressed air |
| Maximum operating pressure on the IN side |
1.0 MPa |
| Ambient temperature |
5-60°C |
| Filter element 74 μm (stainless steel screen) |
74 μm (stainless steel screen) |
| Drainage method |
Manual drainage |
| Bowl |
Polycarbonate bowl (with bowl guard) |
Model No.
| NAF |
- |
6 |
02 |
- |
XL |
D |
M5 |
B |
| Product name |
[1] |
|
[2] |
[3] |
[4] |
[5] |
[1]Pipe connection threads
| 02 |
Rc1/4 |
| 03 |
Rc3/8 |
| 04 |
Rc1/2 |
| 06 |
Rc3/4 |
| 10 |
Rc1 |
[2]Bowl
| Blank |
Polycarbonate bowl (with bowl guard) |
| XL |
Metal bowl |
[3]Drainage method
| Blank |
Manual drainage |
| D |
Automatic drainage |
[4]Filter element
| Blank |
74 μm |
| M5 |
5 μm |
| M25 |
25 μm |
[5]Inclusion of the bracket
| Blank |
Without bracket |
| B |
With bracket |
Model No. NAF-5_ _XL
- Filter element with a large filtration area
Achieves a large flow rate as the pressure drop is small.
- The filter element can be reused after being washed.
- The automatic drainage model is to be installed externally (Model No. SDU-202).
Standard specifications
| Operating fluid |
Compressed air |
| Maximum operating pressure on the IN side |
1.0 MPa |
| Ambient temperature |
5-60°C |
| Filter element |
74 μm |
| Drainage method |
Manual drainage |
Notes:
- For automatic drainage, the lowest operating pressure is 0.10 MPa.
Model No.
| NAF |
- |
5 |
12 |
XL |
D |
| Product name |
[1] |
[2] |
[3] |
[1]Pipe connection threads
| 12 |
Rc1 1/4 |
| 14 |
Rc1 1/2 |
| 20 |
Rc2 |
[2]Cylinder
| XL |
Metal cylinder (with plastic level gauge) |
| XLS |
Metal cylinder (with glass level gauge) |
[3]Drainage method
| Blank |
Manual drainage |
| D |
Automatic drainage (with the SDU-202) |
Model No. AF-530Y
- Filter element with a large filtration area
Achieves a large flow rate as the pressure drop is small.
- The filter element can be reused after being washed.
- The automatic drainage model is to be installed externally (Model No. SDU-202).
Standard specifications
| Operating fluid |
Compressed air |
| Maximum operating pressure on the IN side |
1.0 MPa |
| Ambient temperature |
5-60°C |
| Filter element |
74 μm |
| Drainage method |
Manual drainage |
| Pipe connection threads |
Rc3 |
Notes:
- For automatic drainage, the lowest operating pressure is 0.10 MPa.
Model No.
| AF-530Y |
D |
| Product name |
[1] |
[1]Drainage method
| Blank |
Manual drainage |
| D |
Automatic drainage (with Model No. SDU-202) |