Automatic Drain Unit
Model No. SDU-202
- Automatically discharges drain when it accumulates.
- The bowl is of the easy-to-maintain screw-in type and can be disassembled while it remains installed in the pipe.
- Discharges drain through the tube connected from the drain port (NPT1/8) to the drain pipe.
Standard specifications
| Pipe connection threads |
Drain inlet |
Rc1/4 |
| Drainage port |
NPT1/8 |
| Operating pressure range |
0.10-1.0 MPa |
| Ambient temperature |
5-60°C |
| Drainage capability |
3.5 cc/time (when the pressure is 0.50 MPa) |
| Bowl |
Metal bowl |
| Operation method |
Air-operated |
| Weight |
0.44 kg |
Model No.
| SDU-202 |
B |
| Product name |
[1] |
[1]Inclusion of the bracket
| Blank |
Without bracket |
| B |
With bracket |
Model No. SDU-306XL
- 20A pipe for smooth drain inflow
- High-capacity drainage model
- Drainage using the float and solenoid valve
- Ensures drainage and avoids air loss during drainage.
Standard specifications
| Pipe connection threads |
Drain inlet |
Rc3/4 |
| Drainage port |
Rc1/2 |
| Operating pressure range |
0.05-0.70 MPa |
| Ambient temperature |
5-50°C |
| Drainage capability |
200 cc/time |
| Cylinder |
Metal cylinder (with level gauge) |
| Operation method |
Electricity-operated |
| Weight |
5.3 kg |
| Solenoid model |
Rated voltage |
・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V |
| Allowable voltage fluctuation rate |
-15 to +10% |
| Insulation type |
Type B |
Current value of the solenoid
| - |
Voltage/frequency |
50 Hz |
60 Hz |
| Holding current |
AC 100 V |
0.104 A |
0.084 A |
| AC 200 V |
0.060 A |
0.041 A |
| DC 24 V |
0.490 A |
Model No.
| SDU-306XL |
AC100V |
| Product name |
[1] |
[1]Rated voltage
| AC 100 V |
AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V |
AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V |
DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.