PRODUCTSLUBRICATORS

Lubricator

Model No. NOL-8_ _

Model No. NOL-8_ _
  • Reliably transports oil to the oil supply point, preventing deposition and adherence in the pipe.
  • Extends the lifetime of the friction section because oil does not deteriorate and the heat generation of the bearing is low.
  • Equipment is simple and affordable because the return line is not required.

Standard specifications

Operating fluid Compressed air
Maximum operating pressure 1.0 MPa
Lubricant ISO VG32 turbine oil
Bowl 220 cm³ Polycarbonate bowl (with bowl guard)
1,000 cm³ Metal cylinder
2,000 cm³
5,000 cm³
9,000 cm³

* Caustic soda, caustic potash, and calcic water are excluded.

Model No.

NOL - 8 02 - 1 XL F20
Product name [1] [2] [3] [4]

[1]Pipe connection threads

02 Rc1/4
04 Rc1/2
06 Rc3/4
10 Rc1

[2]Oil tank capacity

Blank 220 cm³
1 1,000 cm³
2 2,000 cm³
5 5,000 cm³
9 9,000 cm³

[3]Bowl and accessories

Blank Polycarbonate bowl
XL Metal cylinder with level gauge
XLS Metal cylinder with glass level gauge
B With bracket (bowl-shaped oil tank only)

[4]Inclusion of the level switch

Blank Without level switch
F_ _ With level switch
FG_ _R With level switch (on right side of terminal box)
FG_ _L With level switch (on left side of terminal box)

Notes:

  • Applicable to a high-capacity oil tank.

Symbol added when the level switch is included and level switch operation

Without terminal box With terminal box for wire connection Liquid level and level switch operation Details of the level switch
Above the upper limit Below the lower limit Maximum contact capacity Maximum operating current Maximum operating voltage
F20 FG20R FG20L - ON AC 50 VA
AC 50 W
AC 0.5 A
DC 0.5 A
AC 300 V
DC 300 V
F21 FG21R FG21L - OFF
F22 FG22R FG22L ON ON
F23 FG23R FG23L OFF OFF
F24 FG24R FG24L OFF ON
F25 FG25R FG25L ON OFF

Notes:

  • For Model No. NOL-8_ _-1XL and NOL-8_ _-2XL oil tanks, only the level switch for the lower limit can be installed.
  • When terminal boxes are included, the terminal boxes for the upper and lower limits are attached.
    In the FG_ _R, the terminal boxes are on the right side and the connection port faces right.
    In the FG_ _L, the terminal boxes are on the left side and the connection port faces left.

Model No. NOL-5_ _

Model No. NOL-5_ _
  • Separates light, fine oil particles (micron fog) and mixes it into operating air.
  • Easily lubricates pneumatic equipment even at a remote location or at the tip of a twisting pipe.
  • Keeps the work environment clean as oil consumption is small.

Standard specifications

Operating fluid Compressed air that has gone through a filter
Operating pressure range 0.05-1.0 MPa
Ambient temperature 5-60°C
Spray method Micron fog (separation type)
Lubricant ISO VG32 (turbine oil or equivalent)
Minimum dripping airflow rate*1 163 dm³/min (ANR)
Bowl Polycarbonate bowl (with bowl guard)
Accessories Drain valve

*1. Flow rate when the air pressure used is 0.7 MPa (vane closed)

Model No.

NOL - 5 02 - 1 XL F20
Product name [1] [2] [3] [4]

[1]Pipe connection threads

02 Rc1/4
03 Rc3/8
04 Rc1/2
06 Rc3/4
10 Rc1

[2]Oil tank capacity

Blank 220 cm³
1 1,000 cm³
2 2,000 cm³
5 5,000 cm³
9 9,000 cm³

[3]Bowl and accessories

Blank Polycarbonate bowl
XL Metal cylinder with level gauge
XLS Metal cylinder with glass level gauge
B With bracket (bowl-shaped oil tank only)

[4]Inclusion of the level switch

Blank Without level switch
F_ _ With level switch
FG_ _R With level switch (on right side of terminal box)
FG_ _L With level switch (on left side of terminal box)

Notes:

  • Applicable to a high-capacity oil tank.

Symbol added when the level switch is included and level switch operation

Without terminal box With terminal box for wire connection Liquid level and level switch operation Details of the level switch
Above the upper limit Below the lower limit Maximum contact capacity Maximum operating current Maximum operating voltage
F20 FG20R FG20L - ON AC 50 VA
AC 50 W
AC 0.5 A
DC 0.5 A
AC 300 V
DC 300 V
F21 FG21R FG21L - OFF
F22 FG22R FG22L ON ON
F23 FG23R FG23L OFF OFF
F24 FG24R FG24L OFF ON
F25 FG25R FG25L ON OFF

Notes:

  • For Model No. NOL-5_ _-1XL and NOL-5_ _-2XL oil tanks, only the level switch for the lower limit can be installed.
  • When terminal boxes are included, the terminal boxes for the upper and lower limits are attached.
    In the FG_ _R, the terminal boxes are on the right side and the connection port faces right.
    In the FG_ _L, the terminal boxes are on the left side and the connection port faces left.

Model No. NOL-1_ _

Model No. NOL-1_ _
  • The large diameter passage allows a large amount to flow.
  • Snap-locked oil amount adjustment knob, and sight dome that allows you to see oil drip from 360°
  • The bowl is an easy-to-maintain clamp ring assembly (Rc1/4-Rc1).
  • Supplies oil without stopping air.

Standard specifications

Operating fluid Compressed air that has gone through a filter
Operating pressure range 0.05-1.0 MPa
Ambient temperature 5-60°C
Spray method Oil fog (total volume type)
Lubricant ISO VG32 (turbine oil or equivalent)
Bowl Model NOL-1_ _ Polycarbonate bowl (with bowl guard)
Model OL-220XL Metal cylinder
Oil tank capacity Model NOL-1_ _ Effective capacity 150 cm³
Nominal capacity 220 cm³
Model OL-220XL Effective capacity 1,500 cm³
Nominal capacity 2,000 cm³
Accessories Drain valve

Notes:

  • Model OL-220XL is 2B size only.
  • Brackets are included with Model OL-220XL.

Model No.

NOL - 1 02 XL
Product name [1] [2]

[1]Pipe connection threads

02 Rc1/4
03 Rc3/8
04 Rc1/2
06 Rc3/4
10 Rc1
20 Rc2

Notes:

  • When the pipe connection threads are 20, Model is OL-220XL. Only XL is applicable as the bowl material and accessories in [2].

[2]Bowl material and accessories

Blank Polycarbonate
XL Cylindrical metal and resin liquid level gauge
B With bracket (bowl-shaped oil tank only)