PRODUCTSSEMI DRY MACHINING LUBRICATION UNITS

External Lubrication Unit, Nozzle

Model No. L32-303

Model No. L32-303
  • Sprays a tiny amount of oil for lubrication, which is ideal for MQL semi-dry machining.
  • Allows you to accurately set a tiny amount of oil to be sprayed.
  • Allows you to easily control spray ON/OFF using the air supply solenoid valve.
  • Nozzle tips ideal for each use are provided.

Standard specifications

Operating fluid Clean compressed air (water- and oil-free)
Maximum operating pressure 1.0 MPa
Operating pressure range 0.25-0.5 MPa
Ambient temperature 5-50°C
Pipe connection threads Rc3/8
Lubricant used General lubricant or plant or animal cutting oil
(except for volatile oil)
Viscosity range of used liquid ISO VG10-68
Setting range of the number of shots 12-20 shots/min: Air pulse control model
1-20 shots/min: Electrical pulse control model
Pump discharge amount (variable) 0.01-0.05 cm³/shot (discharge amount per pump)
Oil tank capacity 700 cm³ (Effective capacity: 500 cm³)
Rated voltage and current values AC 100 V
50 Hz/60 Hz
AC 200 V
50 Hz/60 Hz
DC 24 V
Solenoid valve (for supply air ON/OFF) Current (striking) 0.205 A/0.176 A 0.103 A/0.088 A 0.430 A
Current (holding) 0.180 A/0.146 A 0.088 A/0.072 A
Solenoid valve (for pump driving)*1 Current (striking) 0.024 A/0.023 A 0.016 A/0.015 A 0.080 A
Current (holding) 0.180 A/0.146 A 0.010 A/0.009 A
Level switch *2 Maximum contact capacity AC 50 VA, DC 50 W (when the level switch is included)
Maximum operating current AC/DC 0.5 A
Maximum operating voltage AC/DC 300 V
Weight Approx. 4 kg
Approx. 4.5 kg (with the level switch and terminal box)

*1. This solenoid valve is only included with the electrical pulse control model.

*2. For models with the level switch.

Model No.

L32 - 303 - 1 A  0 1
Product name [1]   [2] [3]

[1]Rated voltage

1 AC 100 V 50/60 Hz, AC 110 V 60 Hz
2 AC 200 V 50/60 Hz, AC 220 V 60 Hz
3 DC 24 V

[2]Pump driving control

0 Air pulse control
1 Electrical pulse control

[3]Level switch

0 Without level switch
1 With level switch (ON at the lower limit)
7 With level switch (OFF at the lower limit)

Model No. L43-3_2

Model No. L43-3_0
  • Advanced MQL semi-dry machining can be adopted without the need for modifications or the addition of special equipment.
  • The dilution or concentration of mist oil can easily be adjusted.
  • The spray pressure from the nozzle is also adjustable.
  • Ideal for many uses where a tiny amount of oil is intermittently sprayed.

Standard specifications

Operating fluid Clean compressed air
Operating pressure range 0.25-0.7 MPa
Ambient temperature 5-50°C
Pipe connection threads IN Rc3/8
Air OUT Tube coupling with an outer diameter of 6 mm
Oil OUT Tube coupling with an outer diameter of 4 mm
Lubricant ISO VG32-68
Adjustment range of the number of shots 1 to 120 shots/min
Oil tank capacity 3,000 cm³ (Effective capacity: 2,400 cm³)
Electrical capacity of the level switch AC 50 VA, DC 50 W (when the level switch is included)

Model No.

L43 - 3 2 2 - 1 3 A 0
Product name [1] [2] [3] [4] [5]

[1]Number of assembled pumps

2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A 10
B 11
C 12

[2]Rated voltage

1 AC 100 V 50/60 Hz, AC 110 V 60 Hz
2 AC 200 V 50/60 Hz, AC 220 V 60 Hz
3 DC 24 V

[3]Oil tank capacity

3 3,000 cm³
Notes: Number of pump assemblies: 2-5
5 5,000 cm³
Notes: Number of pump assemblies: 2-10
7 7,000 cm³
Notes: Number of pump assemblies: 2-12

[4]Pump discharge capacity and filter/regulator Model No.

Discharge capacity Model No.
A 0.015 cm³/shot B73G-3BK-AD1-RMN
B 0.015 cm³/shot B74G-3BK-AD1-RMN
C 0.05 cm³/shot B73G-3BK-AD1-RMN
D 0.05 cm³/shot B74G-3BK-AD1-RMN

[5]Level switch operation

Upper limit Lower limit Automatic oil supply signal
0 - - -
1 - ON -
3 OFF ON -
7 - OFF -
9 ON OFF -
A ON ON -
B OFF OFF -
C OFF OFF Used (ON operation)

Model No. N01-200, Model No. 21547-_ _

Model No. N01-200, Model No. 21547-_ _
  • Enables stable spray because the metal tube does not easily allow the spray position to move.
  • A tip nozzle can be selected from various shapes according to the workpiece shape.
  • The tip nozzle is easy to remove and replace.

Model No.

●Model No. N01-200

N01 - 200 - B 0 0 0
Product name [1] [2] [3] [4]

[1]Installation method

B Bracket
M Magnet

[2]Tube length

0 None
1 100 mm
2 200 mm
3 300 mm
4 400 mm
5 500 mm
6 600 mm
7 700 mm

Notes:

  • When the tube length is 0, select 0 for the nozzle diameter [3] and the nozzle shape and material [4].
    Tube lengths other than 0 are not applicable.

[3]Nozzle diameter

0 None
1 Ø1.0
2 Ø1.2
3 Ø1.4
4 Ø1.6
5 Ø1.8
6 Ø2.0

[4]Nozzle shape and material

Shape Material
0 None None
1 Straight Brass
2 Shape 45 Brass
3 Shape 90 Brass
4 Shape 135 Brass

●Model No. 21547-_ _

21547 - 1 1
Product name [1] [2]

[1]Nozzle shape and material

Shape Material
0 None None
1 Straight Brass
2 Shape 45 Brass
3 Shape 90 Brass
4 Shape 135 Brass
A Straight Aluminum

[2]Nozzle diameter

0 None
1 Ø1.0
2 Ø1.2
3 Ø1.4
4 Ø1.6
5 Ø1.8
6 Ø2.0

Model No. N11-200

Model No. N11-200
  • The lock line hose is employed to adjust the spray direction freely.
  • The double tube system where air and oil collide with each other at the tip enables spraying with a straight stream.
  • The check valve is included to prevent oil leaks.

Model No.

N11 - 200 - B 3 11
Product name [1] [2]

[1]Installation method

B Bracket
M Magnet

[2]Tube length

3 330 mm
5 480 mm
6 630 mm
8 780 mm
9 930 mm
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS