Model No. TX-A
- Lowest-in-class residual pressure achieved by adopting a cross-flow design
- Unique pilot valve structure that reduces delay in the OFF operation due to oil
- Same installation pitch as Model No. MVS-35_ _YC that allows immediate replacement
- A pressure switch can be installed on the standard monitoring port.
- Complies with EU (European Union) standards (CE marking).
- Received a 2021 Good Design Award.
Standard specifications
| Operating fluid | Air | |
| Switching method | Normally closed | |
| Operating method | Internal pilot | |
| Operating pressure range | 0.2-0.7 MPa | |
| Ambient temperature | 5-50°C | |
| Lubrication | Not required | |
| Manual operations | Available | |
| Weight | TX-A040/06J: 2.3 kg, TX-A060/100: 3.5 kg | |
Flow characteristics
| Model No. | Pipe connection threads | Port IN → OUT | Port OUT → EX | |||
| IN and OUT ports | EX port | S [mm²] | Cv | S [mm²] | Cv | |
| TX-A040 | Rc1/2 | Rc3/4 | 40 | 2.1 | 170 | 9.2 |
| TX-A06J | Rc3/4 | Rc3/4 | 40 | 2.1 | 206 | 11.1 |
| TX-A060 | Rc3/4 | Rc1 1/4 | 63 | 3.4 | 307 | 16.6 |
| TX-A100 | Rc1 | Rc1 1/4 | 63 | 3.4 | 393 | 21.3 |
Solenoid specifications
| Electrical wiring | DIN-type terminal DIN EN 175 301-803-A (DIN 43650) |
||
| Rated voltage | AC 100 V 50/60 Hz, AC 110 V 60 Hz AC 200 V 50/60 Hz, AC 220 V 60 Hz AC 110 V 50 Hz AC 220 V 50 Hz DC 24 V |
||
| Allowable voltage fluctuation | −10% to +10% of the rated voltage | ||
| Power consumption*1 | AC 100 V 50/60 Hz, AC 110 V 60 Hz | 19 VA | |
| AC 200 V 50/60 Hz, AC 220 V 60 Hz | 16 VA | ||
| AC 110 V 50 Hz | 19 VA | ||
| AC 220 V 50 Hz | 14 VA | ||
| DC 24 V | 7 W | ||
*1. The power value is per solenoid.
Model No.
| TX-A | 040 | NN | 11 | 0 |
| Product name | [1] | [2] |
[1]Pipe connection threads
| - | IN and OUT ports | EX port |
| 040 | Rc1/2 | Rc3/4 |
| 06J | Rc3/4 | Rc3/4 |
| 060 | Rc3/4 | Rc1 1/4 |
| 100 | Rc1 | Rc1 1/4 |
[2]Rated voltage
| 11 | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| 12 | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| 14 | AC 110 V 50 Hz |
| 16 | AC 220 V 50 Hz |
| 33 | DC 24 V |
Model No. MVS-35_ _YC
- Provides frequent stable operation enabled by the main short-stroke poppet valve.
- Complies with EU standards (CE marking).
Notes: EU standards may not apply to some models.
Standard specifications
| Operating fluid | Compressed air filtered by a filter | ||||
| Operating pressure range | Internal pilot air supply method | 0.15-0.8 MPa | |||
| External pilot air supply method | 0.05-0.8 MPa | ||||
| Ambient temperature | 5-50°C | ||||
| Lubrication | ISO VG 32 turbine oil | ||||
| Manual operations | Non-locking type | ||||
| Ratings of the solenoid | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
|||
| Allowable voltage fluctuation rate | ±10% | ||||
| Insulation type | Type B | ||||
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 1.02 A | 0.87 A |
| AC 200 V | 0.52 A | 0.44 A | |
| Holding current | AC 100 V | 0.48 A | 0.384 A |
| AC 200 V | 0.24 A | 0.192 A |
Typical characteristic values
| Model No. (monitor and weight (kg)) | Pipe connection threads | Effective cross-sectional area (mm2) < Cv value > | |||||
| Without monitoring | Weight | Limit switch model | Proximity switch model | Weight | IN → OUT | OUT → EX | |
| MVS-3512YC | 7.5 | MVS-3512YCL | - | 8.8 | Rc1 1/4 | 190 <10.3> | 960 <51.9> |
| MVS-3514YC | MVS-3514YCL | - | Rc1 1/2 | 190 <10.3> | 1,140 <61.6> | ||
| MVS-3520FYC | 12 | - | MVS-3520FYCK | 17 | Rc2 | 574 <31.1> | 1,596 <86.5> |
Model No.
| MVS-35 | 12 | - | YC | G | L | H | P | S | DC 24 V |
| Product name | [1] | [2] | [3] | [4] | [5] | [6] | [7] |
[1]Pipe connection threads
| IN and OUT ports | EX port | |
| 12 | Rc1 1/4 | Rc2 |
| 14 | Rc1 1/2 | |
| 20F | Rc2 | Rc2 1/2 |
[2]Inclusion of the gland box
| Blank | Without gland box |
| G | With gland box |
[3]Capable of operation monitoring (main valve section)
| Blank | Without operation monitoring |
| K | With proximity switch for alternate current*1 |
| L | With limit switch |
*1. The model with proximity switch for alternate current can be selected only for Model No. MVS-3520F.
[4]Voltage type (solenoid)
| Blank | AC |
| H | DC |
[5]Pilot air supply method
| Blank | Internal pilot air supply method |
| P | External pilot air supply method |
[6]Inclusion of the indicator lamp (solenoid)
| Blank | Without indicator lamp |
| S | With indicator lamp |
[7]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.