Centralized Lubrication System
Model No. TLE-S_04 (Electric Drive)
- Large oil tank capacity (Effective capacity: 9L)
- Reduces the frequency of oil supply work.
- Activates alert equipment or automatic oil supply equipment with the lower or upper limit level switch installed (optional).
- Panel type with separate pressure booster section and micron fog lubricator section
Standard specifications
| Operating fluid |
Clean air that has gone through a filter (74 μm or less) |
| Operating pressure range |
0.3-0.8 MPa |
| Ambient temperature |
5-50°C |
| Oil tank capacity |
9,000 cm³ |
| Fog OUT port |
Rc1/2 (Connected to the main line with bypass adapter Model No. NBA-7_ _.) |
| Lubricant |
ISO VG32 (such as mist type or turbine oil) |
Notes:
- The ball valves for IN and OUT ports are included.
- In addition to the above specifications, prepare the drive unit Model No. TCU-1, 2, or 3 and a filter for the fog generator for Model No. TLE-S_04.
Model No.
| TLE |
- |
S |
1 |
04 |
FG20 |
- |
01 |
| Product name |
|
|
[1] |
|
[2] |
|
|
[1]Rated voltage
| 1 |
AC 100 V |
| 2 |
AC 200 V |
| 3 |
DC 24 V |
[2]Inclusion of the level switch
| Blank |
Without level switch |
| FG20 |
With level switch (ON at the lower limit) |
| FG21 |
With level switch (OFF at the lower limit) |
Model No. TA4-400 (Air Drive)
- The Centralized Lubrication system can easily be introduced by installing a bypass adapter on the existing air line.
- Can be installed at a location far from the main line or at a location ideal for oil supply or maintenance.
- Applicable to the main line with a pipe size of 1B to 2B.
- Generates lubricant fog without decreasing the main line pressure with the built-in pressure booster.
- All-air type ideal when electricity is unavailable or electricity distribution work is not possible
- The oil amount can be checked with the oil level switch.
Standard specifications
| Operating fluid |
Clean air that has gone through a filter (25 μm or less) |
| Operating pressure range |
0.2-0.8 MPa |
| Ambient temperature |
5-50°C |
| Oil tank capacity |
9,000 cm³ (Effective capacity: 7,000 cm³) |
| Fog OUT port |
Rc1/2 (Connected to the main line with bypass adapter Model No. NBA-7_ _.) |
| Lubricant |
ISO VG32 (such as mist type or turbine oil) |
Notes:
- The ball valves for IN and OUT ports are included.
Model No.
| TA4 |
- |
400 |
- |
900 |
0 |
| Product name |
|
|
|
|
[1] |
[1]Inclusion of the level switch
| - |
Max. |
Min. |
| 0 |
Without level switch |
| 4 |
- |
ON |
| 5 |
ON |
- |
| 6 |
ON |
ON |
| C |
- |
OFF |
| D |
OFF |
- |
| E |
OFF |
OFF |
| F |
OFF |
ON |
| G |
ON |
OFF |
Model No. TLC-_ _04
- Easy-to-install compact model
It can be installed on the main line and be used immediately.
- Supplies oil without stopping the line.
It does not exhaust compressed air from the line when supplying oil.
- The main line pressure (OUT side) can be adjusted.
- A pressure gauge is included as standard.
- The amount of stored oil can be checked with the oil level switch (optional).
Standard specifications
| Operating fluid |
Clean air that has gone through a filter (74 μm or less) |
| Maximum operating pressure on the IN side |
1.0 MPa |
| Operating pressure range on the OUT side |
0.1-0.7 MPa |
| Ambient temperature |
5-60°C |
| Oil tank capacity |
5,000 cm³ (Effective capacity: 3,800 cm³) |
| Lubricant |
ISO VG32 (such as mist type or turbine oil) |
Model No.
| TLC |
- |
06 |
04 |
FG20 |
| Product name |
|
[1] |
|
[2] |
[1]Pipe connection threads
[2]Inclusion of the level switch
| Blank |
Without level switch |
| FG20 |
With level switch (ON at the lower limit) |
| FG21 |
With level switch (OFF at the lower limit) |
Model No. TLB-_00
- Easy-to-install compact model
It can be installed on the main line and be used immediately.
- Supplies oil without stopping the line.
It does not exhaust compressed air from the line when supplying oil.
- A pressure gauge is included as standard.
- Generates lubricant fog as before even if the IN side pressure drops.
It continues to generate fog, always maintaining a certain pressure difference (≈ 0.05 MPa) from the primary pressure from the IN side.
- The oil amount can be checked with the oil level switch.
Standard specifications
| Operating fluid |
Clean air that has gone through a filter (74 μm or less) |
| Operating pressure range |
0.1-1.0 MPa |
| Operating pressure on the OUT side |
Pressure lower than the IN side by 0.05 MPa |
| Ambient temperature |
5-60°C |
| Oil tank capacity |
5,000 cm³ (Effective capacity: 3,800 cm³) |
| Lubricant |
ISO VG32 (such as mist type or turbine oil) |
Model No.
| TLB |
- |
A |
00 |
- |
50B |
0 |
| Product name |
|
[1] |
|
|
|
[2] |
[1]Pipe connection threads
| A |
Rc1 1/4 |
| B |
Rc1 1/2 |
| C |
Rc2 |
[2]Inclusion of the level switch
| 0 |
Without level switch |
| 4 |
With level switch (ON at the lower limit) |
| C |
With level switch (OFF at the lower limit) |