PRODUCTSTANK PRESSURE REGULATION SYSTEM

Tank Pressure Regulation System

Model No. H3_-_ _1

Model No. H3_-_ _1
  • High-precision pressure setting, which improves the quality stability and yield of the product
  • Easy-to-operate digital setting completed simply by pressing buttons.
  • At-a-glance digital display
  • Quick high-speed setting reduces setup time.
  • Ideal for adjusting the pressure of balancer tanks in press machines and cushion tanks.

Standard specifications

Operating fluid Compressed air filtered by a filter (74 μm or less)
Operating pressure range on the IN side 0.2-0.95 MPa
Set pressure range 0.1-0.95 MPa
Minimum set pressure width 0.01
Set pressure precision ±1% F.S. (@25°C)
Power supply voltage Model H30-001-70_0 (controller)
Model H3_-_ _1-07_0 (tank pressure regulation system)
・AC 100 V
Model H30-001-70_W (controller)
Model H3_-_ _1-07_W (tank pressure regulation system)
・AC 100 V (±10%)
・DC 24 V (±10%)
Model S12-201-1000 (P/I converter) ・DC 24 V (±1 V)
GOOD signal output ・DC 24 V (±10%)
Interlock signal output ・DC 24 V (±10%)
Model H1_-_01-1000 (control valve) ・AC 100 V
・DC 24 V
Controller-set pressure input Model H30-001-70_ _ BCD parallel or front shift key
Ambient temperature 5-50°C
Ambient relative humidity RH20-85% (no condensation)
Vibration resistance Make the controller vibration-resistant.
Weight Controller Model H30-001-70_ _ 2.5 kg
P/I converter Model S12-201-1000 0.4 kg
Control valve Model H18-801-1000 4 kg
Model H1B-B01-1000 8.8 kg

Notes:

  • Ensure that the pressure does not exceed 0.95 MPa in the compressing process.
  • Lubricate the control valve in a timely fashion. (ISO VG32 turbine oil is suitable.)

Model No. and typical characteristic values

IN and OUT pipe connection threads Air tank capacity (m³) System Components of the electronic tank pressure regulation system
Controller Rated voltage Control valve P/I converter
Rc1 0.3-3 H38-801-07A0 H30-001-70A0 AC 100 V* H18-800-1000
(Pipe connection threads: Rc1)
(EX pipe connection threads: Rc1 1/4)
S12-201-0000
(Pipe connection threads: R1/4)
H38-801-07C0 H30-001-70C0
H38-801-070W H30-001-700W AC 100 V
DC 24 V
H38-801-07BW H30-001-70BW
Rc1 1/2 From 1.1 H3B-B01-07A0 H30-001-70A0 AC 100 V* H1B-B00-1000
(Pipe connection threads: Rc1 1/2)
(EX pipe connection threads: Rc2)
H3B-B01-07C0 H30-001-70C0
H3B-B01-070W H30-001-700W AC 100 V
DC 24 V
H3B-B01-07BW H30-001-70BW

* Includes a built-in DC 24 V power supply for external equipment.

Notes:

  • The allowable speed of filling and exhausting the air tank is 0.03 MPa/sec.
  • When the air tank capacity is small, speed adjustment using the speed control valve or other device is required to reduce the air filling/exhausting speed.
  • The speed control valve is not included as a component of the electronic tank pressure regulation system.
    Request it separately if necessary.

Model No.

●Model No. H3_-_ _1 (tank pressure regulation system)

H3 8 - 8 01 - 07 0 W
Product name [1] [2] [3] [4]

[1]Valve body size

8 1B
B 1 1/2B

[2]Pipe connection threads

8 Rc1
B Rc1 1/2

[3]Accessories

0 With cushion rubber
B With bracket
A Built-in DC power supply (Model No. H10-000 supported), with cushion rubber
C Built-in DC power supply (Model No. H10-000 supported), with bracket

Notes:

  • Select A or C when you are using Model No. H10-000 (control box). A supply voltage of AC 100 V is supported.

[4]Rated voltage

W AC 100 V, DC 24 V
0 AC 100 V

●Model No. H30-001 (controller)

H30 - 001 - 70 0 W
Product name [1] [2]

[1]Accessories

0 With cushion rubber
B With bracket
A Built-in DC power supply (Model No. H10-000 supported),
with cushion rubber
C Built-in DC power supply (Model No. H10-000 supported),
with bracket
E With bracket (installation pitch of the model H20-00_)

Notes:

  • Select A or C when you are using Model No. H10-000 (control box). A supply voltage of AC 100 V is supported.
  • Select E when you are using Model No. H20-00_(control box).

[2]Rated voltage

W AC 100 V, DC 24 V
0 AC 100 V

●Model No. H1_-_01 (control valve)

H1 8 - 8 01 - 1000
Product name [1] [2]

[1]Valve body size

8 1B
B 1 1/2B

[2]Pipe connection threads

8 Rc1
B Rc1 1/2

Model No. HS-4_ _Y2

Model No. HS-400Y2
  • Reduces the setup time before replacing the press.
  • Provides easy operations and reliable pressure adjustment.
  • Reliably blocks the back pressure when the press operates.
  • Retains the pressure in the tank even when the supply pressure is released.

Standard specifications

Model No. HS-404Y2 HS-410Y2 HS-412Y2 HS-414Y2 HS-420Y2
Operating fluid Air
Maximum operating pressure on the primary side 1.0 MPa
Set pressure range 0.1-1.0 MPa
Minimum set pressure width 0.01 MPa
Set pressure precision ±1% F.S.
Rated voltage AC 100 V 50/60 Hz
Allowable voltage fluctuation rate ±10%
Power consumption 95 VA
Allowable back pressure 1.0 MPa
Pipe connection threads Rc1/2 Rc1 Rc1 1/4 Rc1 1/2 Rc2
Exhaust port - Rc1 Rc1 1/2 Rc2
Ambient temperature 5-60°C
Weight 3.5 kg 7.0 kg 13.0 kg

Notes:

  • The setting precision of ±1% F.S. assumes an ambient temperature of 22°C.
    At other temperatures, the precision may change from the above value by up to 0.05% F.S./°C.
  • A silencer is included (except for Model No. HS-404Y2).
    Note that the silencer is separately packaged and not installed in the product.
  • Tank pressure regulation controllers require a pilot regulator.
    Select from the models NRV-802, R42-201, and NRV-3_ _.
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS