PRODUCTSPRESSURE SWITCH

Gap-Sensing Pressure Switch (Model No. S51-1_1)

Model No. S51-1_1

Model No. S51-1_1
  • Small and compact
  • The Ø1.0- or Ø1.5-mm nozzle is used for detection.
    Detection in narrow places is also covered.
  • The indicator lamp is included as standard. (The lamp turns on when detection is ON.)
  • Gap-sensing can be checked visually.
  • These models are connected in series (using a manifold).
  • Even a system for multi-point detection can be made compact, saving space.
  • A pressure gauge to detect back pressure can be installed.

Standard specifications

Model No. S51-1_1-_0_ _
Operating fluid Compressed air that has gone through a 5-μm filter (oil-less)
Pipe connection threads Rc1/8
Ambient temperature 5-60°C
Metering orifice diameter Ø0.7 mm
Detection gap ・0.01-0.15 mm
・0.16-0.3 mm
Setting pressure of the supply air ・0.2 MPa
・0.3 MPa
Detection nozzle diameter Ø1.0 mm
Detection precision ・±0.01 mm
・±0.02 mm
Air consumption ・10 dm³/min (ANR)
・13 dm³/min (ANR)
Output switch contact model 1c
Electric wire connection port G1/2
Detection line Tube with an inner diameter of 4 mm and a length within 4 m
Operating current range
(output switch type)
・Minimal load gap-sensing pressure switch (for programmable controller): 1-100 mA/AC 100 V or DC 24 V
Detection indicator lamp type and dark current

・ Neon lamp (rated voltage: AC 100 V, AC 200 V), dark current: 0.6 mA

・LED lamp (rated voltage: DC 24 V), dark current: 0.85 mA

Weight 0.5 kg

Model No.

S51 - 1 0 1 - 0 0 1 0
Product name [1] [2] [3] [4] [5]

[1]Single or number in series

0 Single
2 - 5 Specify the number in series.

[2]Inclusion of the pressure gauge

0 Without pressure gauge
1 With pressure gauge

[3]Metering orifice diameter

0 Ø0.7 mm
3 Ø1.2 mm

[4]Electrical connection

0 G1/2
1 CAPCON
2 Cord lock

[5]Current capacity and rated voltage of the switch

Minimal load contact model
1 1-100 mA/AC 100 V
3 3-100 mA/DC 24 V (⊖ COM wiring)
4 3-100 mA/DC 24 V (⊕ COM wiring)
High-sensitivity model
B 30-100 mA/AC 100 V
C 20-100 mA/AC 200 V
D 35-100 mA/DC 24 V (⊖ COM wiring)
E 35-100 mA/DC 24 V (⊕ COM wiring)

Model No. S51-1_1 (with Air Purge Valve)

Model No. S51-1_1 (エアパージバルブ付)
  • Model S51-1_1 detector with energy-saving air purge valve directly connected
  • A combination that maximizes the energy-saving characteristic is possible.
  • Up to three series are supported.
  • Any combination of rated voltage, detector, and energy-saving air purge valve is possible.

Standard specifications

Pipe connection threads IN port Rc1/4
Detection port Rc1/8
Operating fluid Compressed air that has gone through a 5-μm filter (oil-less)
Operating pressure 0.2 MPa (supply air pressure)
Ambient temperature 5-50°C
Electric wire connection port (Air purge valve: Model MVS-214-02KS-07 (voltage))
・DIN connector Pg11 (Applicable cable: Ø6-Ø10)
(Gap-sensing pressure switch: Model No. S51-1_1)
・G1/2
・CAPCON
・Cord lock
Maximum number in series Air purge valve: 1 + three gap-sensing pressure switch in series
Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation −15% to +10%
Insulation type Type B

Current value of the solenoid (air purge valve section)

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.165 A 0.140 A
AC 200 V 0.080 A 0.068 A
Holding current AC 100 V 0.102 A 0.079 A
AC 200 V 0.049 A 0.039 A
Direct current DC 24 V 0.27 A

Load current capacity (gap-sensing pressure switch section)

Voltage Minimal load model High-sensitivity model
AC 100 V 1-100 mA 30-100 mA
AC 200 V - 20-100 mA
DC 24 V 1-100 mA 35-100 mA

Model No.

S51 - 1 0 1 - 2 0 0 1
Product name [1] [2] [3] [4] [5]

[1]Number of gap-sensing pressure switches

0 Single
2 2
3 3 (max.)

[2]Inclusion of the pressure gauge

2 Without pressure gauge
3 Pressure gauge with movable marker included
(Range: 0-0.4 MPa)

[3]Metering orifice diameter

0 Ø0.7 mm
3 Ø1.2 mm

[4]Electrical connection

0 G1/2
1 CAPCON
2 Cord lock

[5]Rated voltage

Symbol air purge valve gap-sensing pressure switch /switch
1 AC 100 V AC 100 V/minimal load contact model
3 DC 24 V DC 24 V/minimal load contact model, ⊖ COM wiring
4 DC 24 V DC 24 V/minimal load contact model, ⊕ COM wiring
B AC 100 V AC 100 V/high-sensitivity contact model
C AC 200 V AC 200 V/high-sensitivity contact model
D DC 24 V DC 24 V/high-sensitivity contact model, ⊖ COM wiring
E DC 24 V DC 24 V/high-sensitivity contact model, ⊕ COM wiring
G DC 24 V AC 100 V/minimal load contact model
N DC 24 V AC 100 V/high-sensitivity contact model
H AC 100 V AC 100 V/minimal load contact model, ⊖ COM wiring
K AC 100 V AC 100 V/minimal load contact model, ⊕ COM wiring
R AC 100 V AC 100 V/high-sensitivity contact model, ⊖ COM wiring
U AC 100 V AC 100 V/high-sensitivity contact model, ⊕ COM wiring

Model No. C03-0570 (Series Manifold Panel)

Model No. C3-0570 (連式パネル)
  • Both the filter/regulator and air purge valve are integrated into one panel.
  • One to three gap-sensing pressure switch Model No. S51-101-1_0_ units can be installed.

Standard specifications

Operating fluid Clean compressed air
Maximum operating pressure on the IN side 1.0 MPa
Operating pressure ・0.2 MPa
・0.3 MPa
Pipe connection threads IN port Rc1/4
Detection port Rc1/8
Ambient temperature 5-60°C
air purge valve model Rated voltage ・AC 100 V 50/60 Hz
・AC 200 V 50/60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10%
Detection gap 0.01-0.3 mm
Output switch contact model 1c
Output switch contact capacity High-sensitivity contact model
・30-100 mA/AC 100 V
・20-100 mA/AC 200 V
・35-100 mA/DC 24 V

Model No.

C03-0570 - 0 1
Product name [1] [2]

[1]Air purge valve to be connected

Symbol Model No. Voltage/switch/orifice diameter
0 S51-101-1003 DC 24 V/minimal load contact model/Ø0.7 mm
1 S51-101-1303 DC 24 V/minimal load contact model/Ø1.2 mm
2 S51-101-1001 AC 100 V/minimal load contact model/Ø0.7 mm
3 S51-101-1301 AC 100 V/minimal load contact model/Ø1.2 mm
4 S51-101-100D DC 24 V/high-sensitivity contact model/Ø0.7 mm
5 S51-101-130D DC 24 V/high-sensitivity contact model/Ø1.2 mm
6 S51-101-100B AC 100 V/high-sensitivity contact model/Ø0.7 mm
7 S51-101-130B AC 100 V/high-sensitivity contact model/Ø1.2 mm
8 S51-101-100C AC 200 V/high-sensitivity contact model/Ø0.7 mm
9 S51-101-130C AC 200 V/high-sensitivity contact model/Ø1.2 mm

[2]Number of air purge valves to be connected

1 Single
2 2
3 3