Gap-Sensing Pressure Switch (Model No. AOL-112)
Model No. AOL-112
- Energy-saving structure without a bleed port to adjust the gap
- Allows you to fine-tune the detected pressure.
The pressure ideal for detection can be set. - Allows you to adjust the amount of air supplied.
A unique detection nozzle suited to the purpose can be designed. - A high-precision and robust pressure switch and a flow rate adjustment screw that facilitates adjustment are integrated into a compact unit.
- A grade-A pressure gauge is included as standard.
Standard specifications
| Operating fluid | Compressed air that has gone through a 5-μm filter (oil-less) | |
| Operating pressure range | 0.05-0.2 MPa | |
| Ambient temperature | 5-60°C | |
| Detection gap | 0.01-0.6 mm | |
| Detection precision | ・±0.01 mm (gap: 0.01-0.2 mm) ・±0.03 mm (gap: from 0.2 mm) |
|
| Detected pressure adjustment range | 0.01-0.1 MPa | |
| Output switch contact model | 1c | |
| Output switch contact capacity | High-sensitivity contact model | |
| ・30-100 mA/AC 100 V ・20-100 mA/AC 200 V ・35-100 mA/DC 24 V |
||
| Pipe connection threads | Rc1/4 | |
Model No.
| AOL | - | 112 | A | ST | 1 |
| Product name | [1] | [2] | [3] | ||
[1]Contact type
| Blank | High-sensitivity contact model |
| A | Minimal load contact model |
[2]Inclusion of indicator lamp and its color
| Blank | Without indicator lamp |
| ST | With indicator lamp (transparent) |
| SG | With indicator lamp (green) |
| SR | With indicator lamp (red) |
[3]Characteristics
| Blank | No indicator lamps. COM and NO are connected if the pressure rises. |
| 1 | AC 100 V. The lamp turns off and the load is applied if the pressure rises. |
| 2 | AC 200 V. The lamp turns off and the load is applied if the pressure rises. Notes: Cannot be set in the minimal load contact model (AOL-112A). |
| 3 | DC 24 V. The lamp turns on and the load is applied if the pressure rises. |
| 3P | DC 24 V. The lamp turns on and the load is applied if the pressure drops. |
Model No. AOL-112_×_ (Series)
- Energy-saving structure without a bleed port to adjust the gap
- Allows you to fine-tune the detected pressure.
The pressure ideal for detection can be set. - Allows you to adjust the amount of air supplied.
A unique detection nozzle suited to the purpose can be designed. - A high-precision and robust pressure switch and a flow rate adjustment screw that facilitates adjustment are integrated into a compact unit.
- A grade-A pressure gauge is included as standard.
Standard specifications
| Operating fluid | Compressed air that has gone through a 5-μm filter (oil-less) | |
| Operating pressure range | 0.05-0.2 MPa | |
| Ambient temperature | 5-60°C | |
| Detection gap | 0.01-0.6 mm | |
| Detection precision | ・±0.01 mm (gap: 0.01-0.2 mm) ・±0.03 mm (gap: from 0.2 mm) |
|
| Detected pressure adjustment range | 0.01-0.1 MPa | |
| Output switch contact model | 1c | |
| Output switch contact capacity | High-sensitivity contact model | |
| ・30-100 mA/AC 100 V ・20-100 mA/AC 200 V ・35-100 mA/DC 24 V |
||
| Pipe connection threads | Rc1/4 | |
Model No.
| AOL | - | 112 | A | ST | 1 | × | 2 |
| Product name | [1] | [2] | [3] | [4] | |||
[1]Contact type
| Blank | High-sensitivity contact model |
| A | Minimal load contact model |
[2]Inclusion of indicator lamp and its color
| Blank | Without indicator lamp |
| ST | With indicator lamp (transparent) |
| SG | With indicator lamp (green) |
| SR | With indicator lamp (red) |
[3]Characteristics
| Blank | No indicator lamps. COM and NO are connected if the pressure rises. |
| 1 | AC 100 V. The lamp turns off and the load is applied if the pressure rises. |
| 2 | AC 200 V. The lamp turns off and the load is applied if the pressure rises. Notes: Cannot be set in the minimal load contact model (AOL-112A). |
| 3 | DC 24 V. The lamp turns on and the load is applied if the pressure rises. |
| 3P | DC 24 V. The lamp turns on and the load is applied if the pressure drops. |
[4]Number in series
| 2 | 2 |
| 3 | 3 |
| 4 | 4 |
| 5 | 5 |
| 6 | 6 |
| 7 | 7 |
| 8 | 8 |
Model No. C03-0210 (Series Manifold Panel)
- Both the filter/regulator and air purge valve are integrated into one panel.
- Function-focused panel configuration
- Up to three series are supported.
Standard specifications
| Operating fluid | Clean compressed air | ||
| Maximum operating pressure on the IN side | 1.0 MPa | ||
| Maximum operating pressure | 0.2 MPa | ||
| Pipe connection threads | IN port | Rc1/4 | |
| Detection port | Rc1/8 | ||
| Ambient temperature | 5-60°C | ||
| Air purge valve model | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
|
| Allowable voltage fluctuation rate | −5% to +10% | ||
| Detection gap | ・0.01-0.2 mm (±0.01 mm) ・0.2-0.6 mm (±0.03 mm) |
||
| Output switch contact model | 1c | ||
| Output switch contact capacity | High-sensitivity contact model | ||
| ・30-100 mA/AC 100 V ・20-100 mA/AC 200 V ・35-100 mA/DC 24 V |
|||
Model No.
| C03-0210 | - | A | ST1 | × | 1 | 1 |
| Product name | [1] | [2] | [3] | [4] | ||
[1]Switch type
| Blank | High-sensitivity contact model |
| A | Minimal load contact model |
[2]Indicator lamp type
| ST1 | AC 100 V, transparent |
| ST2 | AC 200 V, transparent Notes: Cannot be set in the minimal load contact model (C03-0210-A). |
| ST3 | DC 24 V, transparent |
| SG1 | AC 100 V, green |
| SG2 | AC 200 V, green Notes: Cannot be set in the minimal load contact model (C03-0210-A). |
| SG3 | DC 24 V, green |
| SR1 | AC 100 V, red |
| SR2 | AC 200 V, red Notes: Cannot be set in the minimal load contact model (C03-0210-A). |
| SR3 | DC 24 V, red |
[3]Number in series
| 1 | Single |
| 2 | 2 |
| 3 | 3 |
[4]Rated voltage of the air purge valve
| 1 | AC 100 V |
| 2 | AC 200 V |
| 3 | DC 24 V |