PRODUCTSPRESSURE SWITCH

Compact Mechanical Pressure Switch

Model No. P02-200

Model No. P02-200
  • Ultracompact pneumatic/electric converter that switches at a preset air pressure
  • Employs a Au clad contact with stable operation characteristics that supports minimal load.
  • The pressure is set to the requested value at shipment.
  • The indicator lamp is on while the air pressure is kept at or above the set value.
  • Basic models without an indicator lamp are also available.
  • The pressure change when the air blowoff nozzle is closed can be used for workpiece positioning check.

Standard specifications

Operating fluid Compressed air or non-corrosive gas
Withstand pressure 0.7 MPa
Pipe connection threads R1/4 (male threads)
Use environment Temperature 5-50°C
Humidity 95% RH max.
Pressure specification range (OFF setting) 0.03-0.37 MPa
Repeat accuracy Within set pressure value ±0.013 MPa (@20°C)
Contact model (standard rated capacity)*1 1c (0.1 A/AC 125 V, 0.1 A/DC 30 V)
Weight 30 g
Materials of main parts*2 Body PPO resin (polyphenylene oxide)
Diaphragm NBR

*1.  When the indicator lamp is used, the standard rated capacity is 40 mA/AC 125 V, 40 mA/DC 30 V. When used in an AC 200 V circuit, use a relay between the indicator lamp and the circuit.

*2.  The body material can be stainless steel and the diaphragm material can be EPDM or Viton. Please consult Azbil TA Co., Ltd. if you want to use them.

Model No.

P02 - 200 - 0 03 0
Model No. - [1] [2] [3]

[1]Drip-proof cover

0 Without drip-proof cover
1 With drip-proof cover

[2]Set pressure (pressure at which the switch is turned OFF)*1

3 0.03 MPa, open/close pressure difference: 0.005*2
5 0.05 MPa, open/close pressure difference: 0.005
8 0.08 MPa, open/close pressure difference: 0.005
12 0.12 MPa, open/close pressure difference: 0.010
16 0.16 MPa, open/close pressure difference: 0.020
20 0.20 MPa, open/close pressure difference: 0.020
25 0.25 MPa, open/close pressure difference: 0.020
32 0.32 MPa, open/close pressure difference: 0.020

[3]Indicator lamp

0 Without indicator lamp, soldered terminal, without lead
2 Without indicator lamp, with lead
(350-mm three-core cable)
7 Without indicator lamp, connector connection, with lead
(350-mm three-core cable)

*1.  The switch is turned OFF when the set pressure is reached in the pressure drop process (OFF setting).

*2.  There is an open/close pressure difference between switch-ON and switch-OFF due to microswitch hysteresis. The switch is turned ON at the pressure higher than the set value by the open/close pressure difference.

Notes:

  • The set pressure can be specified in increments of 0.01 MPa in the specifications range.
  • If you want to use a setting pressure (OFF setting) other than those in the above table, contact Azbil TA Co., Ltd.