PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)

Spool Operated Solenoid Valve (5-Port) (Sub-Base Type)

Model No. 524-_00

Model No. 524-_00
  • No air loss
  • Spool-integrated, low-sliding, soft sealing valve
  • Supports concentrated exhaust.
  • Sub-base type with DIN-connector connection
  • Compact with large flow rate

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range 0.2-1.0 MPa
Withstand pressure 1.5 MPa
Ambient temperature 5-50°C
Lubrication Lubrication required (turbine oil ISO VG32 or equivalent)
Operation frequency At least once a month, 3 Hz or less
Manual operations Non-locking type manual push button
Vibration/shock resistance 3G/30G
Restriction on the installation direction None
Ratings of the solenoid Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −10% to +10% of the rated voltage
Insulation type Type B

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.065 A 0.058 A
AC 200 V 0.035 A 0.032 A
Holding current AC 100 V 0.040 A 0.033 A
AC 200 V 0.022 A 0.019 A
Direct current DC 24 V 0.085 A

Operating pressure and pilot pressure of the external pilot air supply method (optional)

Flow operation method Operating pressure on the main valve side Pilot pressure for operation
Two-position type
Single solenoid
Model No. 524-_00-11_ _
0-0.2 MPa ・When the pressure on the main valve side is 0 to 0.2 MPa: 0.2-0.3 MPa
・When the pressure on the main valve side is 0.2 MPa or more: Same pressure as on the main valve side
0.2-1.0 MPa
Two-position type
Double solenoid
Model No. 524-_00-21_ _
0-0.15 MPa
0.15-1.0 MPa
Three-position type
Model No. 524-_00-_1_ _
0-0.2 MPa
0.2-1.0 MPa

Typical characteristic values

Flow pattern Pipe connection threads Model No.
(internal pilot air supply method, DIN)
Effective cross-sectional area
(mm²)
Response time
(msec)
Weight
(kg)
ON OFF
Two-position type
Single solenoid
Rc1/4 524-200-1003 42 45 65 1.8
Rc3/8 524-300-1003 68
Rc1/2 524-400-1003 80
Rc3/4 524-600-1003 80 1.9
Two-position type
Double solenoid
Rc1/4 524-200-2003 42 26 2
Rc3/8 524-300-2003 68
Rc1/2 524-400-2003 80
Rc3/4 524-600-2003 80 2.1
Three-position type
Closed center
Rc1/4 524-200-3003 41 20 70 2.1
Rc3/8 524-300-3003 60
Rc1/2 524-400-3003 75
Rc3/4 524-600-3003 75 2.2
Three-position type
Exhaust center
Rc1/4 524-200-4003 41 20 70 2.1
Rc3/8 524-300-4003 60
Rc1/2 524-400-4003 75
Rc3/4 524-600-4003 75 2.2
Three-position type
Pressure center
Rc1/4 524-200-5003 41 20 70 2.1
Rc3/8 524-300-5003 60
Rc1/2 524-400-5003 75
Rc3/4 524-600-5003 75 2.2

Model No.

524 - 0 0 0 - 1 0 0 0 DC 24 V
Product name [1] [2] [3] [4] [5] [6] [7]

[1]Pipe connection threads

0 Without sub base
2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4

[2]Thread standard

0 Rc threads
G G threads
N NPT threads

[3]Number of positions and function

1 Two-position type, single solenoid
2 Two-position type, double solenoid
3 Three-position type, closed center
4 Three-position type, exhaust center
5 Three-position type, pressure center

[4]Pilot air supply method

0 Internal pilot air supply method
1 External pilot air supply method

[5]Accessories

0 Non-locking type push button
1 Locking type push button

[6]Electrical wiring

0 DIN-Pg 11 connector
2 DIN-Pg 11 connector with indicator lamp and surge killer
3 DIN-Pg 9 connector
4 DIN-Pg 9 connector with indicator lamp and surge killer

[7]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

Main precautions for use

[Basic]
Make sure to use the product within the specifications.
  1. Use the product at the appropriate voltage and frequency.
  2. Use the product at or below the maximum operating pressure.
  3. Use the specified fluid (clean compressed air).
  4. Do not use the product in a location where there is a risk of fire or explosion.
Do not use the product in atmosphere with corrosive gas, seawater, water, high humidity, or ozone.
When using the product in a low-temperature environment, treat water in the fluid using an air dryer or other device to prevent gelation.
Prevent interference accidents in operating equipment during an abrupt power shutdown or the subsequent restoration.
[Piping and installation]
Remove the port protection plug (or sealing) immediately before piping.
Use sufficiently flushed pipes.
Do not let seal materials enter the pipe during piping.
Properly install pipes, checking the display at each port.
Ensure space for maintenance around equipment.
Do not make the exhaust port smaller.
Install the silencer so that it will not come off.
[Electrical wiring]
Check the power supply voltage to confirm safety before wiring.
For a double solenoid model, prevent both solenoids from becoming live at the same time.
[Operation]
Confirm in advance that operating the manual button will not cause an accident due to the operation of equipment on the OUT side.
Make sure to return the locking type manual button to its original position after operating it.
[Maintenance]
Conduct daily and periodic inspections according to a plan.
Make sure to turn off the power and decrease the air pressure to 0 (zero) in equipment, and before and after it, before repair and overhaul.

Model No. MVS/D-491, Model No. MVD-4_1 (Three-position type)

Model No. MVS/D-491, Model No. MVD-4_1 (3位置式)
  • Sub-base type (Rc1 1/4 to Rc1 1/2)
  • Soft sealing spool valve
  • Large effective cross-sectional area
  • Various sizes to operate Ø32 to Ø320 cylinders
  • Rated voltage: AC 100/200 V (50/60 Hz), DC 24 V

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range 0.15-1.0 MPa
Ambient temperature 5-50°C
Lubrication Oil supply required (ISO VG32 turbine oil or equivalent)
Operation frequency At least once a month, 3 Hz or less
Manual operations Non-locking type manual push button
Ratings of the solenoid Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.210 A 0.435 A
AC 200 V 0.260 A 0.220 A
Holding current AC 100 V 0.240 A 0.192 A
AC 200 V 0.120 A 0.096 A
Direct current DC 24 V 0.646 A (15.5 W)

Typical characteristic values

Operation category Pipe connection threads Model No. Effective cross-sectional area
(mm²)
Response time
(msec)
Weight
(kg)
ON OFF
Two-position type
Single solenoid
Rc1 1/4 MVS-491-12Y 330 60 130 10.5
Rc1 1/2 MVS-491-14Y 350
Two-position type
Double solenoid
Rc1 1/4 MVD-491-12Y 330 32 - 11.4
Rc1 1/2 MVD-491-14Y 350
Three-position type
Closed center
Rc1 1/4 MVD-431-12Y 330 35 70 12.4
Rc1 1/2 MVD-431-14Y 350
Three-position type
Exhaust center
Rc1 1/4 MVD-441-12Y 330
Rc1 1/2 MVD-441-14Y 350
Three-position type
Pressure center
Rc1 1/4 MVD-451-12Y 330
Rc1 1/2 MVD-451-14Y 350

Model No.

MV S - 491 - 12Y H A P R DC 24 V
[1] [2] [3] [4] [5] [6] [7] [8]

[1]Number of solenoids

S Single solenoid
D Double solenoid

[2]Number of positions and function

431 Three-position type, closed center
441 Three-position type, exhaust center
451 Three-position type, pressure center
491 Two-position type, single solenoid, double solenoid

[3]Pipe connection threads

12Y Rc1 1/4
14Y Rc1 1/2

[4]Voltage type

Blank AC
H DC

[5]Use

Blank Standard
A Dual supply

[6]Pilot air supply method

Blank Internal pilot air supply method
P External pilot air supply method

[7]Accessories

Blank Non-locking type manual button
R Locking type manual button (screw-on)
S Indicator lamp and surge killer

[8]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

Model No. MVS/D-492, Model No. MVD-4_2 (Three-position type)

Model No. MVS/D-492, Model No. MVD-4_2 (3位置式)
  • Sub-base type (Rc3/4 to Rc1 1/4)
  • Soft sealing spool valve
  • Large effective cross-sectional area
  • Various sizes to operate Ø32 to Ø320 cylinders
  • Rated voltage: AC 100/200 V (50/60 Hz), DC 24 V

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range 0.15-1.0 MPa
Ambient temperature 5-50°C
Lubrication Oil supply required (turbine oil ISO VG32 or equivalent)*
Operation frequency At least once a month, 3 Hz or less
Manual operations Non-locking type manual push button
Ratings of the solenoid Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

* Can be used even without an oil supply.

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.165 A 0.140 A
AC 200 V 0.080 A 0.068 A
Holding current AC 100 V 0.102 A 0.079 A
AC 200 V 0.049 A 0.039 A
Direct current DC 24 V 0.270 A

Typical characteristic values

Operation category Pipe connection threads Model No. Effective cross-sectional area
(mm²)
Response time
(msec)
Weight
(kg)
ON OFF
Two-position type
Single solenoid
Rc3/4 MVS-492-06Y 185 59 134 3.6
Rc1 MVS-492-10Y 195
Rc1 1/4 MVS-492-12JY 215 4.6
Two-position type
Double solenoid
Rc3/4 MVD-492-06Y 185 69 - 4.5
Rc1 MVD-492-10Y 195
Rc1 1/4 MVD-492-12JY 215 5.3
Three-position type
Closed center
Rc3/4 MVD-432-06Y 185 166 76 5.3
Rc1 MVD-432-10Y 195
Rc1 1/4 MVD-432-12JY 215 6.1
Three-position type
Exhaust center
Rc3/4 MVD-442-06Y 185 166 76 5.3
Rc1 MVD-442-10Y 195
Rc1 1/4 MVD-442-12JY 215 6.1
Three-position type
Pressure center
Rc3/4 MVD-452-06Y 185 166 76 5.3
Rc1 MVD-452-10Y 195
Rc1 1/4 MVD-452-12JY 215 6.1

Model No.

MV S - 492 - 06Y H A P R DC 24 V
[1] [2] [3] [4] [5] [6] [7] [8]

[1]Number of solenoids

S Single solenoid
D Double solenoid

[2]Number of positions and function

432 Three-position type, closed center
442 Three-position type, exhaust center
452 Three-position type, pressure center
492 Two-position type, single solenoid, double solenoid

[3]Pipe connection threads

06Y Rc3/4
10Y Rc1
12JY Rc1 1/4 (overport)

[4]Voltage type

Blank AC
H DC

[5]Use

Blank Standard
A Dual supply

[6]Pilot air supply method

Blank Internal pilot air supply method
P External pilot air supply method

[7]Accessories

Blank Non-locking type manual button
R Locking type manual button (screw-on)
S Indicator lamp and surge killer

[8]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.