PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)
Spool Operated Solenoid Valve (5-Port) (Direct Piping Type)
Model No. 501-200
- The packing is made of fluoro-rubber.
Excellent in oil resistance, chemical resistance, weather resistance, and ozone resistance. Packings experience very little swelling, contraction, and deterioration due to age - Superior durability
- Large effective cross-sectional area
The valve is compact but can also be used to operate large cylinders.
Standard specifications
| Operating fluid | Compressed air filtered by a filter | |||
| Operating pressure range | 0.15-0.9 MPa | |||
| Ambient temperature | 5-50°C | |||
| Lubrication | Oil supply required (ISO VG32 turbine oil or equivalent)* | |||
| Manual operations | Non-locking type manual push button | |||
| Ratings of the solenoid | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||
| Allowable voltage fluctuation rate | −15% to +10% | |||
| Insulation type | Type B | |||
* Can be used even without an oil supply.
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.065 A | 0.058 A |
| AC 200 V | 0.035 A | 0.032 A | |
| Holding current | AC 100 V | 0.040 A | 0.033 A |
| AC 200 V | 0.022 A | 0.019 A | |
| Direct current | DC 24 V | 0.085 A | |
Typical characteristic values
| Operation category | Pipe connection threads | Model No. | Effective cross-sectional area (mm²) < Cv value > |
Response time (msec) |
Weight (kg) |
|||
| DIN-type-connector connection (with indicator lamp and surge killer) |
Free lead connection | 1 → 2 1 → 4 |
2 → 3 4 → 5 |
ON | OFF | |||
| Two-position type Single solenoid |
Rc1/4 | 501-200-1004 | 501-200-1006 | 21 <1.1> |
18 <0.97> |
15 | 15 | 0.18 |
| Two-position type Double solenoid |
501-200-2004 | 501-200-2006 | 16 | - | 0.27 | |||
| Three-position type Closed center |
501-200-3004 | 501-200-3006 | 18 <0.97> |
13 <0.70> |
16 | 26 | 0.37 | |
| Three-position type Exhaust center |
501-200-4004 | 501-200-4006 | ||||||
| Three-position type Pressure center |
501-200-5004 | 501-200-5006 | ||||||
Model No.
| 501 | - | 200 | - | 1 | 0 | 0 | 4 | AC 100 V |
| Product name | [1] | [2] | [3] | [4] | ||||
[1]Number of positions and function
| 1 | Two-position type, single solenoid |
| 2 | Two-position type, double solenoid |
| 3 | Three-position type, closed center |
| 4 | Three-position type, exhaust center |
| 5 | Three-position type, pressure center |
[2]Accessories
| 0 | Non-locking type push button |
| 1 | Turn lock lever |
[3]Electrical connection
| 4 | With DIN terminal, indicator lamp, and surge killer |
| 6 | Free lead connection |
[4]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.
Model No. 501-2T0
- The pilot spool valve has good responsiveness and can operate frequently.
- The newly developed solenoid further improves durability.
- No air loss
Standard specifications
| Operating fluid | Compressed air filtered by a filter | |||
| Operating pressure range | 0.15-0.9 MPa | |||
| Ambient temperature | 5-50°C | |||
| Lubrication | Oil supply required (turbine oil ISO VG32 or equivalent)* | |||
| Manual operations | Non-locking type manual push button | |||
| Pipe connection threads | Ports 1, 3, and 5 common ports |
Rc1/4 (connected to the manifold bed) | ||
| Ports 1, 2, and 4 individual ports |
Rc1/4 (connected to each valve body) | |||
| Effective cross-sectional area (mm²) | Single valve (1 → 2, 1 → 4) and (2 → 3, 4 → 5) ・21/18 Two-position single/double solenoid ・18/13 Three-position type |
|||
| Maximum number in series | 8 | |||
| Ratings of the solenoid | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||
| Allowable voltage fluctuation rate | −15% to +10% | |||
| Insulation type | Type B | |||
* Can be used even without an oil supply.
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.065 A | 0.058 A |
| AC 200 V | 0.035 A | 0.032 A | |
| Holding current | AC 100 V | 0.040 A | 0.033 A |
| AC 200 V | 0.022 A | 0.019 A | |
| Direct current | DC 24 V | 0.085 A (2W) | |
Model No.
| 501 | - | 2T0 | × | 2 | L | - | 1 | AC 100 V |
| Product name | [1] | [2] | [3] | [4] | ||||
[1]Number of valves installed in the manifold block
| 2 | 2 |
| 4 | 4 |
| 6 | 6 |
| 8 | 8 |
Notes:
- Use an even number of valves in the manifold block.
If there is an odd number of valves, select the next even number and install a shielding plate to the unused connection.
[2]Accessories
| Blank | Non-locking type manual push button Free lead connection |
| L | Locking type manual handle (screw-on) Free lead connection |
| S | Non-locking type manual push button DIN connector (with indicator lamp and surge killer) |
| D | Locking type manual handle (screw-on) DIN connector (with indicator lamp and surge killer) |
[3]Specification of the solenoid valve to be installed
| - | 2 or 4 ports | Model No. | Accessories | Function |
| 1 | Rc1/4 | 501-2T0-1006 501-2T0-1016 501-2T0-1004 501-2T0-1014 |
None L S D |
Single solenoid |
| 2 | Rc1/4 | 501-2T0-2006 501-2T0-2016 501-2T0-2004 501-2T0-2014 |
None L S D |
Double solenoid |
| 3 | Rc1/4 | 501-2T0-3006 501-2T0-3016 501-2T0-3004 501-2T0-3014 |
None L S D |
Three-position type Closed center |
| 4 | Rc1/4 | 501-2T0-4006 501-2T0-4016 501-2T0-4004 501-2T0-4014 |
None L S D |
Three-position type Exhaust center |
| 5 | Rc1/4 | 501-2T0-5006 501-2T0-5016 501-2T0-5004 501-2T0-5014 |
None L S D |
Three-position type Pressure center |
| Y | Rc1/4 | Shielding plate | Cover for unused valve connection port | |
[4]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.