PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)

Spool Operated Solenoid Valve (5-Port) (Direct Piping Type)

Model No. 501-200

Model No. 501-200
  • The packing is made of fluoro-rubber.
    Excellent in oil resistance, chemical resistance, weather resistance, and ozone resistance. Packings experience very little swelling, contraction, and deterioration due to age
  • Superior durability
  • Large effective cross-sectional area
    The valve is compact but can also be used to operate large cylinders.

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range 0.15-0.9 MPa
Ambient temperature 5-50°C
Lubrication Oil supply required (ISO VG32 turbine oil or equivalent)*
Manual operations Non-locking type manual push button
Ratings of the solenoid Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10%
Insulation type Type B

* Can be used even without an oil supply.

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.065 A 0.058 A
AC 200 V 0.035 A 0.032 A
Holding current AC 100 V 0.040 A 0.033 A
AC 200 V 0.022 A 0.019 A
Direct current DC 24 V 0.085 A

Typical characteristic values

Operation category Pipe connection threads Model No. Effective cross-sectional area (mm²)
< Cv value >
Response time
(msec)
Weight
(kg)
DIN-type-connector connection
(with indicator lamp and surge killer)
Free lead connection 1 → 2
1 → 4
2 → 3
4 → 5
ON OFF
Two-position type
Single solenoid
Rc1/4 501-200-1004 501-200-1006 21
<1.1>
18
<0.97>
15 15 0.18
Two-position type
Double solenoid
501-200-2004 501-200-2006 16 0.27
Three-position type
Closed center
501-200-3004 501-200-3006 18
<0.97>
13
<0.70>
16 26 0.37
Three-position type
Exhaust center
501-200-4004 501-200-4006
Three-position type
Pressure center
501-200-5004 501-200-5006

Model No.

501 - 200 - 1 0 0 4 AC 100 V
Product name [1] [2] [3] [4]

[1]Number of positions and function

1 Two-position type, single solenoid
2 Two-position type, double solenoid
3 Three-position type, closed center
4 Three-position type, exhaust center
5 Three-position type, pressure center

[2]Accessories

0 Non-locking type push button
1 Turn lock lever

[3]Electrical connection

4 With DIN terminal, indicator lamp, and surge killer
6 Free lead connection

[4]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

Model No. 501-2T0

Model No. 501-2T0
  • The pilot spool valve has good responsiveness and can operate frequently.
  • The newly developed solenoid further improves durability.
  • No air loss

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range 0.15-0.9 MPa
Ambient temperature 5-50°C
Lubrication Oil supply required (turbine oil ISO VG32 or equivalent)*
Manual operations Non-locking type manual push button
Pipe connection threads Ports 1, 3, and 5
common ports
Rc1/4 (connected to the manifold bed)
Ports 1, 2, and 4
individual ports
Rc1/4 (connected to each valve body)
Effective cross-sectional area (mm²) Single valve (1 → 2, 1 → 4) and (2 → 3, 4 → 5)
・21/18 Two-position single/double solenoid
・18/13 Three-position type
Maximum number in series 8
Ratings of the solenoid Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10%
Insulation type Type B

* Can be used even without an oil supply.

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.065 A 0.058 A
AC 200 V 0.035 A 0.032 A
Holding current AC 100 V 0.040 A 0.033 A
AC 200 V 0.022 A 0.019 A
Direct current DC 24 V 0.085 A (2W)

Model No.

501 - 2T0 × 2 L - 1 AC 100 V
Product name [1] [2] [3] [4]

[1]Number of valves installed in the manifold block

2 2
4 4
6 6
8 8

Notes:

  • Use an even number of valves in the manifold block.
    If there is an odd number of valves, select the next even number and install a shielding plate to the unused connection.

[2]Accessories

Blank Non-locking type manual push button
Free lead connection
L Locking type manual handle (screw-on)
Free lead connection
S Non-locking type manual push button
DIN connector (with indicator lamp and surge killer)
D Locking type manual handle (screw-on)
DIN connector (with indicator lamp and surge killer)

[3]Specification of the solenoid valve to be installed

- 2 or 4 ports Model No. Accessories Function
1 Rc1/4 501-2T0-1006
501-2T0-1016
501-2T0-1004
501-2T0-1014
None
L
S
D
Single solenoid
2 Rc1/4 501-2T0-2006
501-2T0-2016
501-2T0-2004
501-2T0-2014
None
L
S
D
Double solenoid
3 Rc1/4 501-2T0-3006
501-2T0-3016
501-2T0-3004
501-2T0-3014
None
L
S
D
Three-position type
Closed center
4 Rc1/4 501-2T0-4006
501-2T0-4016
501-2T0-4004
501-2T0-4014
None
L
S
D
Three-position type
Exhaust center
5 Rc1/4 501-2T0-5006
501-2T0-5016
501-2T0-5004
501-2T0-5014
None
L
S
D
Three-position type
Pressure center
Y Rc1/4 Shielding plate Cover for unused valve connection port

[4]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

Model No. MVS/D-495, Model No. MVD-4_5 (Three-position type)

Model No. MVS/D-495,Model No. MVD-4_5 (3位置式)
  • No air loss
    Useful for saving energy and costs.
  • Because the exhaust port opens after the air supply port closes,
    unnecessary air is not consumed during valve switching.
  • Reliable operation even in a harsh environment
    This improves productivity.
  • Soft sealing allows for safe use in dusty locations and ensures reliable sealing.
  • Compact and lightweight
    It is more than strong enough to drive a cylinder one class above as the airflow rate is so large.
  • The two-position double solenoid model has detents, is highly shock-resistant, and prevents malfunction.

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range 0.2-1.0 MPa
Ambient temperature 5-50°C
Lubrication ISO VG32 turbine oil
Manual operations Non-locking type manual push button
Effective cross-sectional area< Cv value > 35 mm² <1.9>
Ratings of the solenoid Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate ±10%
Insulation type Type B

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.065 A 0.058 A
AC 200 V 0.035 A 0.032 A
Holding current AC 100 V 0.040 A 0.033 A
AC 200 V 0.022 A 0.019 A
Direct current DC 24 V 0.085 A

Typical characteristic values

Operation category Pipe connection threads Model No. Response time (msec) Weight (kg)
ON OFF
Two-position type
Single solenoid
Rc1/4 MVS-495-02Y 35 65 0.6
Rc3/8 MVS-495-03JY
Two-position type
Double solenoid
Rc1/4 MVD-495-02Y 25 - 0.8
Rc3/8 MVD-495-03JY
Three-position type
Closed center
Rc1/4 MVD-435-02Y 45 55 1.0
Rc3/8 MVD-435-03JY
Three-position type
Exhaust center
Rc1/4 MVD-445-02Y
Rc3/8 MVD-445-03JY
Three-position type
Pressure center
Rc1/4 MVD-455-02Y
Rc3/8 MVD-455-03JY

Model No.

MV S - 495 - 02Y H A P R S DC 24 V
[1] [2] [3] [4] [5] [6] [7] [8] [9]

[1]Number of solenoids

S Single solenoid
D Double solenoid

[2]Number of positions and function

435 Three-position type, closed center
445 Three-position type, exhaust center
455 Three-position type, pressure center
495 Two-position type, single solenoid, double solenoid

[3]Pipe connection threads

02Y Rc1/4
03JY Rc3/8 (overport)

[4]Voltage type

Blank AC
H DC

[5]Use

Blank Standard
A Dual supply

[6]Pilot air supply method

Blank Internal pilot air supply method
P External pilot air supply method

[7]Accessories

Blank Non-locking type manual button
R Locking type manual button

[8]Socket section

Blank DIN.Pg11
S DIN-Pg 11 with indicator lamp and surge killer

[9]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS