PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)

Spool Operated Master Valve (5-Port)

Model No. 524-_00-_00M

Model No. 524-_00-_00M
  • Sub-base type (Rc1/4 to Rc3/4)
  • Soft sealing spool valve
  • Large effective cross-sectional area
  • Various models and sizes to operate Ø32 to Ø200 cylinders
  • Pilot pressure for operation: +0 to +0.3 MPa from the main valve pressure

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range 0-1.0 MPa
Pressure range on the main valve side 0-1.0 MPa
Pilot pressure setting Pressure range on the main valve side: 0-0.2 MPa 0.2-0.3 MPa
Pressure range on the main valve side: 0.2-1.0 MPa From the pressure range on the main valve side to the pressure range on the main valve side + 0.3 MPa*
Ambient temperature 5-60°C
Lubrication Oil supply required (turbine oil ISO VG32 or equivalent)
Notes: Can be used even without oil supply under certain conditions.

* If the pilot pressure is higher than the main valve pressure, ensure that the pressure difference does not exceed 0.3 MPa.

Typical characteristic values

Operation category Model No. Pipe connection threads Effective cross-sectional area (mm²) Weight (kg)
Two-position single pilot 524-200-100M Rc1/4 42 1.7
524-300-100M Rc3/8 68
524-400-100M Rc1/2 80
524-600-100M Rc3/4 80 1.8
Two-position multi pilot 524-200-200M Rc1/4 42 1.9
524-300-200M Rc3/8 68
524-400-200M Rc1/2 80
524-600-200M Rc3/4 80 2.0
Three-position multi pilot
Closed center
524-200-300M Rc1/4 41 2.0
524-300-300M Rc3/8 60
524-400-300M Rc1/2 75
524-600-300M Rc3/4 75 2.1
Three-position multi pilot
Exhaust center
524-200-400M Rc1/4 41 2.0
524-300-400M Rc3/8 60
524-400-400M Rc1/2 75
524-600-400M Rc3/4 75 2.1
Three-position multi pilot
Pressure center
524-200-500M Rc1/4 41 2.0
524-300-500M Rc3/8 60
524-400-500M Rc1/2 75
524-600-500M Rc3/4 75 2.1

Model No.

524 - 0 00 - 1 00M
Product name [1] [2]

[1]Pipe connection threads

0 Without sub base
2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4

[2]Number of positions and function

1 Two-position type, single pilot
2 Two-position type, double pilot
3 Three-position type, closed center
4 Three-position type, exhaust center
5 Three-position type, pressure center