PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)
Poppet Type Solenoid Valve for Vacuum (2/3-Port)
Poppet Type Solenoid Valve for Vacuum (2-Port) Model No. 26_-_00
- High durability
- Flange connection that facilitates installation and removal of the unit
- DIN-type electric wire connector
- The pipe connection direction can be switched.
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Operating fluid | ||||
| Operating pressure range | −0.1-0 MPa* | ||||
| Withstand pressure | 1.6 MPa | ||||
| Ambient temperature | 5-50°C | ||||
| Manual operations | Non-locking type manual push button | ||||
| Standard accessories | Non-locking type manual push button and installation bracket | ||||
| Solenoid model | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
|||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | ||||
| Insulation type | Type B | ||||
* Supply compressed air at 0.20-0.30 MPa as the external pilot pressure.
Current value of the solenoid (two-position type)
| Two-position type | Model No. 26_-_00 | ||
| Voltage/frequency | 50 Hz | 60 Hz | |
| Striking current | AC 100 V | 0.165 A | 0.140 A |
| AC 200 V | 0.080 A | 0.068 A | |
| Holding current | AC 100 V | 0.102 A | 0.079 A |
| AC 200 V | 0.049 A | 0.039 A | |
| Direct current | DC 24 V | 0.270 A | |
Notes:
- For other voltages, contact Azbil TA Co., Ltd.
Typical characteristic values
●Two-position single solenoid normally closed
| Model No. | Pipe connection threads (IN, OUT) |
Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
Weight (kg) |
| IN - OUT | ||||
| 263-200-03B0 | Rc1/4 | 40 <2.2> | 60 or less | 1.3 |
| 263-300-03B0 | Rc3/8 | 58 <3.1> | ||
| 263-400-03B0 | Rc1/2 | 71 <3.8> | ||
| 268-400-03B0 | 112 <6.1> | 100 or less | 2 | |
| 268-600-03B0 | Rc3/4 | 170 <9.2> | ||
| 268-800-03B0 | Rc1 | 206 <11.1> | ||
| 268-A00-03B0 | Rc1 1/4 | 218 <11.8> | ||
| 26B-A00-03B0 | 450 <24.3> | 300 or less | 6.2 | |
| 26B-B00-03B0 | Rc1 1/2 | 510 <27.5> | ||
| 26B-C00-03B0 | Rc2 | 570 <30.8> |
●Two-position single solenoid normally open
| Model No. | Pipe connection threads (IN, OUT) |
Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
Weight (kg) |
| IN - OUT | ||||
| 263-200-13B0 | Rc1/4 | 40 <2.2> | 60 or less | 1.3 |
| 263-300-13B0 | Rc3/8 | 53 <2.9> | ||
| 263-400-13B0 | Rc1/2 | 63 <3.4> | ||
| 268-400-13B0 | 112 <6.1> | 100 or less | 2 | |
| 268-600-13B0 | Rc3/4 | 165 <8.9> | ||
| 268-800-13B0 | Rc1 | 195 <10.5> | ||
| 268-A00-13B0 | Rc1 1/4 | 206 <11.1> | ||
| 26B-A00-13B0 | 480 <25.9> | 300 or less | 6.2 | |
| 26B-B00-13B0 | Rc1 1/2 | 550 <29.7> | ||
| 26B-C00-13B0 | Rc2 | 600 <32.4> |
* The response time is measured when the compressed air is 0.30 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the Model No.
Model No.
| 26 | 3 | - | 2 | 00 | - | 0 | 3 | B | 0 | AC100V |
| Product name | [1] | [2] | [3] | [4] | [5] | [6] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Function
| 0 | Single solenoid, normally closed |
| 1 | Single solenoid, normally open |
[4]Accessories
| B | Non-locking type manual push button and installation bracket |
| R | Locking type manual push button and installation bracket |
[5]Operation method
| 0 | Solenoid |
| 2 | Solenoid with indicator lamp and surge killer |
[6]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.
Poppet Type Solenoid Valve for Vacuum (3-Port) Model No. 36_-_00
- High durability
- Flange connection that facilitates installation and removal of the unit
- DIN-type electric wire connector
- The pipe connection direction can be switched.
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Air (vacuum) | |||||||
| Operating pressure range | −0.1-0 MPa* | |||||||
| Withstand pressure | 1.6 MPa | |||||||
| Ambient temperature | 5-50°C | |||||||
| Manual operations | Non-locking type manual push button | |||||||
| Standard accessories | Non-locking type manual push button and installation bracket | |||||||
| Solenoid model | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||||||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |||||||
| Insulation type | Type B | |||||||
* Prepare compressed air at 0.3 MPa or more as the external pilot pressure.
Notes:
- When using a positive pressure (up to 0.15 MPa) for vacuum break, prepare compressed air at 0.5 to 1.0 MPa as the pilot pressure for operation.
- For other voltages, contact Azbil TA Co., Ltd.
Current value of the solenoid (two-position type)
| Two-position type | Model 36_-_00 | ||
| Voltage/frequency | 50 Hz | 60 Hz | |
| Striking current | AC 100 V | 0.165 A | 0.140 A |
| AC 200 V | 0.080 A | 0.068 A | |
| Holding current | AC 100 V | 0.102 A | 0.079 A |
| AC 200 V | 0.049 A | 0.039 A | |
| Direct current | DC 24 V | 0.270 A | |
Typical characteristic values
| Model No. | Port 1 or 2 pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
Port 3 pipe connection threads | Weight (kg) |
|
| Between ports 1 and 2 | Between ports 2 and 3 | |||||
| 363-200-63B0 | Rc1/4 | 42.5 <2.3> | 56 <3.0> | 30 or less | Rc1/2 | 1.3 |
| 363-300-63B0 | Rc3/8 | 63 <3.4> | 85 <4.6> | |||
| 363-400-63B0 | Rc1/2 | 75 <4.0> | 100 <5.4> | |||
| 368-400-63B0 | 106 <5.7> | 160 <8.6> | 30 or less | Rc1 | 2 | |
| 368-600-63B0 | Rc3/4 | 170 <9.1> | 236 <12.7> | |||
| 368-800-63B0 | Rc1 | 190 <10.2> | 250 <13.5> | |||
| 368-A00-63B0 | Rc1 1/4 | 190 <10.2> | 250 <13.5> | Rc1 1/4 | ||
| 36B-A00-63B0 | 450 <24.3> | 530 <28.6> | 100 or less | Rc2 | 6.2 | |
| 36B-B00-63B0 | Rc1 1/2 | 500 <27.0> | 600 <32.4> | |||
| 36B-C00-63B0 | Rc2 | 530 <28.6> | 600 <32.4> | |||
* The response time is measured when the compressed air is 0.30 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model.
Model No.
| 36 | 3 | - | 2 | 00 | - | 63 | B | 0 | AC100V |
| Product name | [1] | [2] | [3] | [4] | [5] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Accessories
| B | Non-locking type manual push button and installation bracket |
| R | Locking type manual push button and installation bracket |
[4]Operation method
| 0 | Solenoid |
| 2 | Solenoid with indicator lamp and surge killer |
[5]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.