PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)
Poppet Type Solenoid Valve for High/Low Pressure Switching (3-Port)
Model No. 363/8-_01, Model No. 36B-_00
- Poppet structure that facilitates maintenance
- The external pilot method achieves reliable operation.
- Ideal as a control valve for a large flow rate.
- Valve with superior durability
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Compressed air purified by a filter | |||||
| Operating pressure | Pressure range on the main valve side*1 | High pressure side (IN) | 0.05-1.0 MPa | |||
| Low pressure side (EX) | 0-0.85 MPa | |||||
| Pilot pressure (P) setting*2 | P = Pressure on the high pressure side (IN) + (0 to 0.2 MPa) and P ≥ Pressure on the low pressure side (EX) + (0.15 MPa) | |||||
| Withstand pressure | 1.6 MPa | |||||
| Ambient temperature | 5-50°C | |||||
| Standard accessories | Non-locking type manual push button and installation bracket | |||||
| Rated voltage | ・AC 100 V 50 Hz, AC 110 V 60 Hz ・AC 200 V 50 Hz, AC 220 V 60 Hz ・DC 24 V |
|||||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |||||
| Insulation type | Type B | |||||
*1. The high pressure side pressure (IN port) must be equal to or higher than the low pressure side pressure (EX port).
The operating pressure range of Model No. 36B-_00 (Rc1 1/4 to Rc2) is 0.2 to 1.0 MPa.
*2. Ensure that the pilot pressure does not exceed 1.0 MPa.
Current value of the solenoid (two-position type (external pilot method))
| Two-position type (external pilot method) |
- | Model No. 363/8-_01 | Model No. 36B-_00 | ||
| Voltage /frequency |
50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Striking current | AC 100 V | 0.30 A [0.065 A] | 0.26 A [0.058 A] | 0.510 A [0.750 A] | 0.435 A [0.630 A] |
| AC 200 V | 0.15 A [0.035 A] | 0.13 A [0.032 A] | 0.260 A [0.380 A] | 0.220 A [0.335 A] | |
| Holding current | AC 100 V | 0.20 A [0.040 A] | 0.18 A [0.033 A] | 0.240 A [0.240 A] | 0.192 A [0.192 A] |
| AC 200 V | 0.10 A [0.075 A] | 0.09 A [0.019 A] | 0.120 A [0.120 A] | 0.096 A [0.096 A] | |
| Direct current | DC 24 V | 0.40 A [0.075 A] | 0.646 A [0.646 A] | ||
Notes:
- The current values in square brackets are for the two-position double solenoid model.
Typical characteristic values
●Two-position double solenoid
| Model No. | IN, OUT, and EX port pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
Weight (kg) | |
| IN - OUT | OUT - EX | ||||
| 363-201-91B0 | Rc1/4 | 44 <2.4> | 42 <2.3> | 40 or less | 1.4 |
| 363-301-91B0 | Rc3/8 | 53 <2.8> | 50 <2.7> | ||
| 363-401-91B0 | Rc1/2 | 55 <3.0> | 60 <3.2> | ||
| 368-401-91B0 | 125 <6.8> | 135 <7.3> | 40 or less | 2.0 | |
| 368-601-91B0 | Rc3/4 | 180 <9.7> | 170 <9.2> | ||
| 368-801-91B0 | Rc1 | 195 <10.5> | 180 <9.7> | ||
| 368-A01-91B0 | Rc1 1/4 | 200 <10.8> | 180 <9.7> | ||
| 36B-A00-91B0 | 410 <22.2> | 386 <20.9> | 40 or less | 7.0 | |
| 36B-B00-91B0 | Rc1 1/2 | 450 <24.4> | 407 <22.0> | ||
| 36B-C00-91B0 | Rc2 | 480 <26.0> | 423 <22.9> | ||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model.
●Two-position single solenoid normally closed
| Model No. | IN, OUT, and EX port pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
Weight (kg) | |
| IN-OUT | OUT-EX | ||||
| 363-201-81B0 | Rc1/4 | 44 <2.4> | 42 <2.3> | 40 or less | 1.1 |
| 363-301-81B0 | Rc3/8 | 53 <2.8> | 50 <2.7> | ||
| 363-401-81B0 | Rc1/2 | 55 <3.0> | 60 <3.2> | ||
| 368-401-81B0 | 125 <6.8> | 135 <7.3> | 40 or less | 1.8 | |
| 368-601-81B0 | Rc3/4 | 180 <9.7> | 170 <9.2> | ||
| 368-801-81B0 | Rc1 | 195 <10.5> | 180 <9.7> | ||
| 368-A01-81B0 | Rc1 1/4 | 200 <10.8> | 180 <9.7> | ||
| 36B-A00-81B0 | 410 <22.2> | 386 <20.9> | 40 or less | 6.4 | |
| 36B-B00-81B0 | Rc1 1/2 | 450 <24.4> | 407 <22.0> | ||
| 36B-C00-81B0 | Rc2 | 480 <26.0> | 423 <22.9> | ||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model.
Model No.
| 36 | 3 | - | 2 | 01 | - | 8 | 1 | B | 0 | AC 100 V |
| Product name | [1] | [2] | [3] | [4] | [5] | [6] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Function
| 8 | Single solenoid, dual supply |
| 9 | Double solenoid, dual supply |
[4]Accessories
| B | Non-locking type manual push button and installation bracket |
| R | Locking type manual push button and installation bracket |
[5]Operation method
| 0 | Solenoid |
| 2 | Solenoid with indicator lamp and surge killer |
[6]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.