PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)
Poppet Type Solenoid Valve (2/3/4-Port)
Poppet Type Solenoid Valve (2-Port) Model No. 263/8-_01, Model No. 26B-_00
- Poppet structure that facilitates maintenance
- The pilot method achieves reliable operation
- Ideal as a switch valve for a large flow rate.
- Normally closed and open valves are available.
- The internal pilot can easily be modified to the external pilot using a rubber plug.
- Valve with superior durability
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Compressed air filtered by a filter | ||||
| Operating pressure range | Internal pilot air supply method | 0.15-1.0 MPa | |||
| External pilot air supply method | 0.05-1.0 MPa | ||||
| Withstand pressure | 1.6 MPa | ||||
| Ambient temperature | 5-50°C | ||||
| Lubrication | Lubrication required (ISO VG32 turbine oil or equivalent)* | ||||
| Standard accessories | Non-locking type manual push button and installation bracket | ||||
| Rated voltage | ・AC 100 V 50 Hz, AC 110 V 60 Hz ・AC 200 V 50 Hz, AC 220 V 60 Hz ・DC 24 V |
||||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | ||||
| Insulation type | Type B | ||||
* Can be used even without an oil supply.
Current value of the solenoid (two-position type)
| Two-position type | - | Model No. 263/8-_01 | Model No. 26B-_00 | ||
| Voltage/frequency | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Striking current | AC 100 V | 0.30 A [0.065 A] | 0.26 A [0.058 A] | 0.510 A [0.750 A] | 0.435 A [0.630 A] |
| AC 200 V | 0.15 A [0.035 A] | 0.13 A [0.032 A] | 0.260 A [0.380 A] | 0.220 A [0.335 A] | |
| Holding current | AC 100 V | 0.20 A [0.040 A] | 0.18 A [0.033 A] | 0.240 A [0.240 A] | 0.192 A [0.192 A] |
| AC 200 V | 0.10 A [0.075 A] | 0.09 A [0.019 A] | 0.120 A [0.120 A] | 0.096 A [0.096 A] | |
| Direct current | DC 24 V | 0.40 A [0.075 A] | 0.646 A [0.646 A] | ||
Notes:
- The current values in square brackets are for the two-position double solenoid.
- For other voltages, contact Azbil TA Co., Ltd.
Typical characteristic values
●Two-position single solenoid normally closed
| Model No. | Pipe connection threads (IN and OUT) | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
Weight (kg) |
| IN - OUT | ||||
| 263-201-00B0 | Rc1/4 | 40 <2.2> | 40 or less | 1.1 |
| 263-301-00B0 | Rc3/8 | 58 <3.1> | ||
| 263-401-00B0 | Rc1/2 | 71 <3.8> | ||
| 268-401-00B0 | 106 <5.7> | 50 or less | 1.8 | |
| 268-601-00B0 | Rc3/4 | 170 <9.1> | ||
| 268-801-00B0 | Rc1 | 190 <10.2> | ||
| 268-A01-00B0 | Rc1 1/4 | 190 <10.2> | ||
| 26B-A00-01B0 | 450 <24.3> | 50 or less | 6.2 | |
| 26B-B00-01B0 | Rc1 1/2 | 510 <27.5> | ||
| 26B-C00-01B0 | Rc2 | 570 <30.8> |
●Two-position single solenoid normally open
| Model No. | Pipe connection threads (IN and OUT) | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
Weight (kg) |
| IN - OUT | ||||
| 263-201-10B0 | Rc1/4 | 40 <2.2> | 40 or less | 1.1 |
| 263-301-10B0 | Rc3/8 | 53 <2.9> | ||
| 263-401-10B0 | Rc1/2 | 63 <3.4> | ||
| 268-401-10B0 | 112 <6.1> | 50 or less | 1.8 | |
| 268-601-10B0 | Rc3/4 | 170 <9.1> | ||
| 268-801-10B0 | Rc1 | 190 <10.2> | ||
| 268-A01-10B0 | Rc1 1/4 | 190 <10.2> | ||
| 26B-A00-11B0 | 480 <25.9> | 50 or less | 6.2 | |
| 26B-B00-11B0 | Rc1 1/2 | 550 <29.7> | ||
| 26B-C00-11B0 | Rc2 | 600 <34.4> |
●Two-position double solenoid
| Model No. | Pipe connection threads (IN and OUT) | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
Weight (kg) |
| IN - OUT | ||||
| 263-201-20B0 | Rc1/4 | 40 <2.2> | 40 or less | 1.2 |
| 263-301-20B0 | Rc3/8 | 58 <3.1> | ||
| 263-401-20B0 | Rc1/2 | 71 <3.8> | ||
| 268-401-20B0 | 106 <5.7> | 50 or less | 1.9 | |
| 268-601-20B0 | Rc3/4 | 170 <9.1> | ||
| 268-801-20B0 | Rc1 | 190 <10.2> | ||
| 268-A01-20B0 | Rc1 1/4 | 190 <10.2> | ||
| 26B-A00-21B0 | 450 <24.3> | 60 or less | 6.8 | |
| 26B-B00-21B0 | Rc1 1/2 | 510 <27.5> | ||
| 26B-C00-21B0 | Rc2 | 570 <30.8> |
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 26B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.
Model No.
| 26 | 3 | - | 2 | 01 | - | 0 | 0 | B | 0 | AC100V |
| Product name | [1] | [2] | [3] | [4] | [5] | [6] | [7] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Function
| 0 | Single solenoid, normally closed |
| 1 | Single solenoid, normally open |
| 2 | Double solenoid |
[4]Pilot air supply method
| 0 | Internal pilot air supply method |
| 1 | External pilot air supply method |
[5]Accessories
| B | Non-locking type manual push button and installation bracket |
| R | Locking type manual push button and installation bracket |
[6]Operation method
| 0 | Solenoid |
| 2 | Solenoid with indicator lamp and surge killer |
[7]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.
Poppet Type Solenoid Valve (3-Port) Model No. 363/8-_01, Model No. 36B-_00
- Poppet structure that facilitates maintenance
- The external pilot method achieves reliable operation.
- Ideal as a control valve for a large flow rate.
- Valve with superior durability
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Compressed air purified by a filter | |
| Operating pressure range | Internal pilot air supply method | 0.15-1.0 MPa*1 |
| External pilot air supply method | 0.05-1.0 MPa | |
| Withstand pressure | 1.6 MPa | |
| Ambient temperature | 5-50°C | |
| Lubrication | Lubrication required (ISO VG32 turbine oil or equivalent)*2 | |
| Standard accessories | Non-locking type manual push button and installation bracket | |
| Rated voltage | ・AC 100 V 50 Hz, AC 110 V 60 Hz ・AC 200 V 50 Hz, AC 220 V 60 Hz ・DC 24 V |
|
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |
| Insulation type | Type B | |
*1 The operating pressure range of Model No. 36B-_00 is 0.2 to 1.0 MPa.
*2 Can be used even without an oil supply.
Current value of the solenoid (two-position type)
| - | - | Model No. 363/8-_01 | Model No. 36B-_00 | ||
| Voltage/frequency | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Striking current | AC 100 V | 0.30 A [0.065 A] | 0.26 A [0.058 A] | 0.510 A [0.750 A] | 0.435 A [0.630 A] |
| AC 200 V | 0.15 A [0.035 A] | 0.13 A [0.032 A] | 0.260 A [0.380 A] | 0.220 A [0.335 A] | |
| Holding current | AC 100 V | 0.20 A [0.040 A] | 0.18 A [0.033 A] | 0.240 A [0.240 A] | 0.192 A [0.192 A] |
| AC 200 V | 0.10 A [0.022 A] | 0.09 A [0.019 A] | 0.120 A [0.120 A] | 0.096 A [0.096 A] | |
| Direct current | DC 24 V | 0.40 A [0.075 A] | 0.646 A [0.646 A] | ||
Notes:
- The current values in square brackets are for the two-position double solenoid.
- For other voltages, contact Azbil TA Co., Ltd.
Typical characteristic values
●Two-position double solenoid
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
EX port pipe connection threads | Weight (kg) | |
| IN - OUT | OUT - EX | |||||
| 363-201-20B0 | Rc1/4 | 42.5 <2.3> | 56 <3.0> | 40 or less | Rc1/2 | 1.2 |
| 363-301-20B0 | Rc3/8 | 63 <3.4> | 85 <4.6> | |||
| 363-401-20B0 | Rc1/2 | 75 <4.0> | 100 <5.4> | |||
| 368-401-20B0 | 106 <5.7> | 160 <8.6> | 40 or less | Rc1 | 1.9 | |
| 368-601-20B0 | Rc3/4 | 170 <9.1> | 236 <12.7> | |||
| 368-801-20B0 | Rc1 | 190 <10.2> | 250 <13.5> | |||
| 368-A01-20B0 | Rc1 1/4 | 190 <10.2> | 250 <13.5> | Rc1 1/4 | ||
| 36B-A00-21B0 | 450 <24.3> | 530 <28.6> | 40 or less | Rc2 | 6.8 | |
| 36B-B00-21B0 | Rc1 1/2 | 500 <27.0> | 600 <32.4> | |||
| 36B-C00-21B0 | Rc2 | 530 <28.6> | 600 <32.4> | |||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 36B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.
●Two-position single solenoid normally closed
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
EX port pipe connection threads | Weight (kg) | |
| IN - OUT | OUT - EX | |||||
| 363-201-00B0 | Rc1/4 | 42.5 <2.3> | 56 <3.0> | 30 or less | Rc1/2 | 1.1 |
| 363-301-00B0 | Rc3/8 | 63 <3.4> | 85 <4.6> | |||
| 363-401-00B0 | Rc1/2 | 75 <4.0> | 100 <5.4> | |||
| 368-401-00B0 | 106 <5.7> | 160 <8.6> | 30 or less | Rc1 | 1.8 | |
| 368-601-00B0 | Rc3/4 | 170 <9.1> | 236 <12.7> | |||
| 368-801-00B0 | Rc1 | 190 <10.2> | 250 <13.5> | |||
| 368-A01-00B0 | Rc1 1/4 | 190 <10.2> | 250 <13.5> | Rc1 1/4 | ||
| 36B-A00-01B0 | 450 <24.3> | 530 <28.6> | 30 or less | Rc2 | 6.2 | |
| 36B-B00-01B0 | Rc1 1/2 | 500 <27.0> | 600 <32.4> | |||
| 36B-C00-01B0 | Rc2 | 530 <28.6> | 600 <32.4> | |||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 36B-_00 (Rc1 1/4 to Rc2) above uses air supply with the external pilot method.
●Two-position single solenoid normally open
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
EX port pipe connection threads | Weight (kg) | |
| IN - OUT | OUT - EX | |||||
| 363-201-10B0 | Rc1/4 | 47.5 <2.5> | 56 <3.0> | 30 or less | Rc1/2 | 1.1 |
| 363-301-10B0 | Rc3/8 | 60 <3.2> | 71 <3.8> | |||
| 363-401-10B0 | Rc1/2 | 63 <3.4> | 71 <3.8> | |||
| 368-401-10B0 | 112 <6.0> | 140 <7.5> | 30 or less | Rc1 | 1.8 | |
| 368-601-10B0 | Rc3/4 | 150 <8.1> | 176 <9.5> | |||
| 368-801-10B0 | Rc1 | 190 <10.2> | 180 <9.7> | |||
| 368-A01-10B0 | Rc1 1/4 | 190 <10.2> | 180 <9.7> | Rc1 1/4 | ||
| 36B-A00-11B0 | 400 <21.6> | 425 <22.9> | 30 or less | Rc2 | 6.2 | |
| 36B-B00-11B0 | Rc1 1/2 | 480 <25.9> | 500 <27.0> | |||
| 36B-C00-11B0 | Rc2 | 480 <25.9> | 500 <29.0> | |||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 36B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.
Model No.
| 36 | 3 | - | 2 | 01 | - | 0 | 0 | B | 0 | AC100V |
| Product name | [1] | [2] | [3] | [4] | [5] | [6] | [7] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Function
| 0 | Single solenoid, normally closed |
| 1 | Single solenoid, normally open |
| 2 | Double solenoid |
[4]Pilot air supply method
| 0 | Internal pilot air supply method |
| 1 | External pilot air supply method |
[5]Accessories
| B | Non-locking type manual push button and installation bracket |
| R | Locking type manual push button and installation bracket |
[6]Operation method
| 0 | Solenoid |
| 2 | Solenoid with indicator lamp and surge killer |
[7]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.
Poppet Type Solenoid Valve (4-Port) Model No. 463/8-_01, Model No. 46B-_00
- High durability
- Flange connection that facilitates installation and removal of the unit
- DIN-type electric wire connector
- The pipe connection direction can be switched.
- The internal and external pilot methods can be switched.
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Compressed air purified by a filter | |
| Operating pressure range | Internal pilot air supply method | 0.15-1.0 MPa*1 |
| External pilot air supply method | 0.05-1.0 MPa | |
| Withstand pressure | 1.6 MPa | |
| Ambient temperature | 5-50°C | |
| Lubrication | Lubrication required (ISO VG32 turbine oil or equivalent)*2 | |
| Standard accessories | Non-locking type manual push button and installation bracket | |
| Rated voltage | ・AC 100 V 50 Hz, AC 110 V 60 Hz ・AC 200 V 50 Hz, AC 220 V 60 Hz ・DC 24 V |
|
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |
| Insulation type | Type B | |
*1 The operating pressure range of Model No. 46B-_00 is 0.2 to 1.0 MPa.
*2 Can be used even without an oil supply.
Current value of the solenoid (two-position type)
| Two-position type | - | Model No. 463/8-_01 | Model No. 46B-_00 | ||
| Voltage/frequency | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Striking current | AC 100 V | 0.30 A [0.065 A] | 0.26 A [0.058 A] | 0.510 A [0.750 A] | 0.435 A [0.630 A] |
| AC 200 V | 0.15 A [0.035 A] | 0.13 A [0.032 A] | 0.260 A [0.380 A] | 0.220 A [0.335 A] | |
| Holding current | AC 100 V | 0.20 A [0.040 A] | 0.18 A [0.033 A] | 0.240 A [0.240 A] | 0.192 A [0.192 A] |
| AC 200 V | 0.10 A [0.075 A] | 0.09 A [0.019 A] | 0.120 A [0.120 A] | 0.096 A [0.096 A] | |
| Direct current | DC 24 V | 0.40 A [0.075 A] | 0.646 A [0.646 A] | ||
Notes:
- The current values in square brackets are for the two-position double solenoid.
- For other voltages, contact Azbil TA Co., Ltd.
Current value of the solenoid (three-position type)
| Three-position type | - | Model No. 463/8-_01 | Model No. 46B-_00 | ||
| Voltage/frequency | 50 Hz | 60 Hz | 50 Hz | 60 Hz | |
| Striking current | AC 100 V | 0.30 A [0.065 A] | 0.26 A [0.058 A] | 0.510 A [0.750 A] | 0.435 A [0.630 A] |
| AC 200 V | 0.15 A [0.022 A] | 0.13 A [0.018 A] | 0.260 A [0.380 A] | 0.220 A [0.335 A] | |
| Holding current | AC 100 V | 0.20 A [0.040 A] | 0.18 A [0.033 A] | 0.240 A [0.240 A] | 0.192 A [0.192 A] |
| AC 200 V | 0.10 A [0.022 A] | 0.09 A [0.019 A] | 0.120 A [0.120 A] | 0.095 A [0.095 A] | |
| Direct current | DC 24 V | 0.40 A [0.085 A] | 0.646 A [0.646 A] | ||
Notes:
- The current values in square brackets are for the three-position type closed center model.
- For other voltages, contact Azbil TA Co., Ltd.
Typical characteristic values
●Two-position single solenoid
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
EX port pipe connection threads | Weight (kg) |
|||
| IN - OUT | OUT - EX | |||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | |||||
| 463-201-10B0 | Rc1/4 | 42.5 <2.3> | 42.5 <2.3> | 53 <2.8> | 53 <2.8> | 30 or less | Rc1/2 | 1.8 |
| 463-301-10B0 | Rc3/8 | 56 <3.0> | 56 <3.0> | 67 <3.6> | 80 <4.3> | |||
| 463-401-10B0 | Rc1/2 | 60 <3.2> | 67 <3.6> | 71 <3.8> | 90 <4.8> | |||
| 468-401-10B0 | 112 <6.0> | 118 <6.3> | 150 <8.1> | 160 <8.6> | 40 or less | Rc1 | 3.5 | |
| 468-601-10B0 | Rc3/4 | 160 <8.6> | 170 <9.1> | 190 <10.2> | 180 <9.7> | |||
| 468-801-10B0 | Rc1 | 180 <9.7> | 190 <10.2> | 190 <10.2> | 200 <10.8> | |||
| 468-A01-10B0 | Rc1 1/4 | 180 <9.7> | 190 <10.2> | 190 <10.2> | 200 <10.8> | Rc1 1/4 | ||
| 46B-A00-11B0 | 400 <21.6> | 450 <24.3> | 425 <22.9> | 530 <28.6> | 50 or less | Rc2 | 11.5 | |
| 46B-B00-11B0 | Rc1 1/2 | 480 <25.9> | 500 <27.0> | 500 <27.0> | 560 <30.2> | |||
| 46B-C00-11B0 | Rc2 | 480 <25.9> | 530 <28.6> | 500 <27.0> | 560 <30.2> | |||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.
●Two-position double solenoid
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
EX port pipe connection threads | Weight (kg) |
|||
| IN - OUT | OUT - EX | |||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | |||||
| 463-201-20B0 | Rc1/4 | 42.5 <2.3> | 42.5 <2.3> | 53 <2.8> | 53 <2.8> | 40 or less | Rc1/2 | 1.9 |
| 463-301-20B0 | Rc3/8 | 56 <3.0> | 56 <3.0> | 67 <3.6> | 80 <4.3> | |||
| 463-401-20B0 | Rc1/2 | 60 <3.2> | 67 <3.6> | 71 <3.8> | 90 <4.8> | |||
| 468-401-20B0 | 112 <6.0> | 118 <6.3> | 150 <8.1> | 160 <8.6> | 40 or less | Rc1 | 3.6 | |
| 468-601-20B0 | Rc3/4 | 160 <8.6> | 170 <9.1> | 190 <10.2> | 180 <9.7> | |||
| 468-801-20B0 | Rc1 | 180 <9.7> | 190 <10.2> | 190 <10.2> | 200 <10.8> | |||
| 468-A01-20B0 | Rc1 1/4 | 180 <9.7> | 190 <10.2> | 190 <10.2> | 200 <10.8> | Rc1 1/4 | ||
| 46B-A00-21B0 | 400 <21.6> | 450 <24.3> | 425 <22.9> | 530 <28.6> | 50 or less | Rc2 | 12.1 | |
| 46B-B00-21B0 | Rc1 1/2 | 480 <25.9> | 500 <27.0> | 500 <27.0> | 560 <30.2> | |||
| 46B-C00-21B0 | Rc2 | 480 <25.9> | 530 <28.6> | 500 <27.0> | 560 <30.2> | |||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.
●Three-position double solenoid closed center
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
EX port pipe connection threads | Weight (kg) |
|||
| IN - OUT | OUT - EX | |||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | |||||
| 463-201-30B0 | Rc1/4 | 43 <2.3> | 43 <2.3> | 58 <3.1> | 56 <3.0> | 50 or less | Rc1/2 | 2.9 |
| 463-301-30B0 | Rc3/8 | 63 <3.4> | 63 <3.4> | 88 <4.7> | 73 <3.9> | |||
| 463-401-30B0 | Rc1/2 | 76 <4.1> | 76 <4.1> | 100 <5.4> | 80 <4.3> | |||
| 468-401-30B0 | 124 <6.7> | 124 <6.7> | 175 <9.4> | 150 <8.1> | 60 or less | Rc1 | 5.2 | |
| 468-601-30B0 | Rc3/4 | 175 <9.4> | 175 <9.4> | 250 <13.5> | 180 <9.7> | |||
| 468-801-30B0 | Rc1 | 200 <10.8> | 200 <10.8> | 282 <15.2> | 195 <10.5> | |||
| 468-A01-30B0 | Rc1 1/4 | 200 <10.8> | 200 <10.8> | 285 <15.4> | 186 <10.0> | Rc1 1/4 | ||
| 46B-A00-31B0 | 540 <29.2> | 540 <29.2> | 590 <31.9> | 380 <20.5> | 100 or less | Rc2 | 15.3 | |
| 46B-B00-31B0 | Rc1 1/2 | 540 <29.2> | 540 <29.2> | 630 <34.0> | 380 <20.5> | |||
| 46B-C00-31B0 | Rc2 | 545 <29.5> | 545 <29.5> | 680 <36.7> | 390 <21.1> | |||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.
●Three-position type double solenoid exhaust center
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
EX port pipe connection threads | Weight (kg) |
|||
| IN - OUT | OUT - EX | |||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | |||||
| 463-201-40B0 | Rc1/4 | 37 <2.0> | 37 <2.0> | 41 <2.2> | 40 <2.1> | 30 or less | Rc1/2 | 2.3 |
| 463-301-40B0 | Rc3/8 | 58 <3.1> | 58 <3.1> | 78 <4.2> | 65 <3.5> | |||
| 463-401-40B0 | Rc1/2 | 70 <3.7> | 70 <3.7> | 104 <5.6> | 75 <4.0> | |||
| 468-401-40B0 | 122 <6.5> | 122 <6.5> | 170 <9.1> | 130 <7.0> | 40 or less | Rc1 | 4.1 | |
| 468-601-40B0 | Rc3/4 | 170 <9.1> | 170 <9.1> | 245 <13.2> | 145 <7.8> | |||
| 468-801-40B0 | Rc1 | 195 <10.5> | 195 <10.5> | 280 <15.1> | 150 <8.1> | |||
| 468-A01-40B0 | Rc1 1/4 | 196 <10.5> | 196 <10.5> | 280 <15.1> | 150 <8.1> | Rc1 1/4 | ||
| 46B-A00-41B0 | 450 <24.3> | 450 <24.3> | 540 <29.2> | 265 <14.3> | 40 or less | Rc2 | 12.2 | |
| 46B-B00-41B0 | Rc1 1/2 | 510 <27.6> | 510 <27.6> | 645 <34.9> | 270 <14.6> | |||
| 46B-C00-41B0 | Rc2 | 525 <28.4> | 525 <28.4> | 680 <36.7> | 270 <14.6> | |||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.
●Three-position double solenoid pressure center
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Response time* (msec) |
EX port pipe connection threads | Weight (kg) |
|||
| IN - OUT | OUT - EX | |||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | |||||
| 463-201-50B0 | Rc1/4 | 35 <1.8> | 35 <1.8> | 40 <2.1> | 40 <2.1> | 30 or less | Rc1/2 | 2.3 |
| 463-301-50B0 | Rc3/8 | 50 <2.7> | 50 <2.7> | 66 <3.5> | 64 <3.4> | |||
| 463-401-50B0 | Rc1/2 | 53 <2.8> | 53 <2.8> | 73 <3.9> | 70 <4.0> | |||
| 468-401-50B0 | 120 <6.4> | 120 <6.4> | 153 <8.2> | 145 <7.8> | 40 or less | Rc1 | 4.1 | |
| 468-601-50B0 | Rc3/4 | 175 <9.4> | 175 <9.4> | 185 <10.0> | 170 <9.1> | |||
| 468-801-50B0 | Rc1 | 190 <10.2> | 200 <10.8> | 200 <10.8> | 180 <9.7> | |||
| 468-A01-50B0 | Rc1 1/4 | 184 <9.9> | 192 <10.3> | 198 <10.7> | 177 <9.5> | Rc1 1/4 | ||
| 46B-A00-51B0 | 450 <24.3> | 460 <24.9> | 470 <25.4> | 450 <24.3> | 40 or less | Rc2 | 12.2 | |
| 46B-B00-51B0 | Rc1 1/2 | 510 <27.6> | 510 <27.6> | 515 <27.8> | 480 <25.9> | |||
| 46B-C00-51B0 | Rc2 | 510 <27.6> | 510 <27.6> | 540 <29.2> | 500 <27.0> | |||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Notes:
- Show the rated voltage at the end of the model No.
- Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.
Model No.
| 46 | 3 | - | 2 | 01 | - | 1 | 0 | B | 0 | AC100V |
| Product name | [1] | [2] | [3] | [4] | [5] | [6] | [7] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Number of positions and function
| 1 | Two-position type, single solenoid, normally open |
| 2 | Two-position type, double solenoid |
| 3 | Three-position type, closed center |
| 4 | Three-position type, exhaust center |
| 5 | Three-position type, pressure center |
[4]Pilot air supply method
| 0 | Internal pilot air supply method |
| 1 | External pilot air supply method |
[5]Accessories
| B | Non-locking type manual push button and installation bracket |
| R | Locking type manual push button and installation bracket |
[6]Operation method
| 0 | Solenoid |
| 2 | Solenoid with indicator lamp and surge killer |
[7]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.