PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)
Poppet Type Master Valve (2/3/4-Port)
Poppet Type Master Valve (2-Port) Model No. 26_-_00-_0BM
- Poppet structure that facilitates maintenance
- The pilot method achieves reliable operation.
- Ideal as a switch valve for a large flow rate.
- Normally closed and open valves are available.
- Valve with superior durability
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Compressed air filtered by a filter | ||
| Operating pressure | Pressure range on the main valve side | 0.05-1.0 MPa | |
| Pilot pressure setting | Pressure range on the main valve side: 0.05-0.15 MPa | 0.15-0.3 MPa | |
| Pressure range on the main valve side: 0.15-1.0 MPa | From the pressure range on the main valve side to the pressure range on the main valve side + 0.3 MPa (However, ensure that 1.0 MPa is not exceeded.) |
||
| Withstand pressure | 1.6 MPa | ||
| Ambient temperature | 5-60°C | ||
| Lubrication | Lubrication required (ISO VG32 turbine oil or equivalent)* | ||
| Standard accessories | Installation bracket | ||
* Can be used even without an oil supply.
Typical characteristic values
●Two-position single pilot normally closed
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Weight (kg) |
| IN - OUT | |||
| 263-200-00BM | Rc1/4 | 40 <2.2> | 0.7 kg |
| 263-300-00BM | Rc3/8 | 58 <3.1> | |
| 263-400-00BM | Rc1/2 | 71 <3.8> | |
| 268-400-00BM | 112 <6.1> | 1.4 kg | |
| 268-600-00BM | Rc3/4 | 170 <9.2> | |
| 268-800-00BM | Rc1 | 190 <10.2> | |
| 268-A00-00BM | Rc1 1/4 | 190 <10.2> | |
| 26B-A00-00BM | 450 <24.3> | 5.6 kg | |
| 26B-B00-00BM | Rc1 1/2 | 510 <27.5> | |
| 26B-C00-00BM | Rc2 | 570 <30.8> |
●Two-position single pilot normally open
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Weight (kg) |
| IN - OUT | |||
| 263-200-10BM | Rc1/4 | 40 <2.2> | 0.7 kg |
| 263-300-10BM | Rc3/8 | 53 <2.9> | |
| 263-400-10BM | Rc1/2 | 63 <3.4> | |
| 268-400-10BM | 112 <6.1> | 1.4 kg | |
| 268-600-10BM | Rc3/4 | 165 <8.9> | |
| 268-800-10BM | Rc1 | 190 <10.2> | |
| 268-A00-10BM | Rc1 1/4 | 190 <10.2> | |
| 26B-A00-10BM | 480 <25.9> | 5.6 kg | |
| 26B-B00-10BM | Rc1 1/2 | 550 <29.7> | |
| 26B-C00-10BM | Rc2 | 600 <32.4> |
Model No.
| 26 | 3 | - | 2 | 00 | - | 0 | 0BM |
| Product name | [1] | [2] | [3] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Function
| 0 | Normally closed |
| 1 | Normally open |
Poppet Type Master Valve (3-Port) Model No. 36_-_00-_0BM
- Poppet structure that facilitates maintenance
- The pilot method achieves reliable operation.
- Ideal as a switch valve for a large flow rate.
- Normally closed and open valves are available.
- Valve with superior durability
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Compressed air filtered by a filter | ||
| Operating pressure | Pressure range on the main valve side | 0.05-1.0 MPa | |
| Pilot pressure setting | Pressure range on the main valve side: 0.05-0.15 MPa | 0.15-0.3 MPa | |
| Pressure range on the main valve side: 0.15-1.0 MPa | From the pressure range on the main valve side to the pressure range on the main valve side + 0.3 MPa (However, ensure that 1.0 MPa is not exceeded.) |
||
| Withstand pressure | 1.6 MPa | ||
| Ambient temperature | 5-60°C | ||
| Lubrication | Lubrication required (ISO VG32 turbine oil or equivalent)* | ||
| Standard accessories | Installation bracket | ||
* Can be used even without an oil supply.
Typical characteristic values
●Two-position single pilot normally closed
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
EX port pipe connection threads | Weight (kg) | |
| IN - OUT | OUT - EX | ||||
| 363-200-00BM | Rc1/4 | 42.5 <2.3> | 56 <3.0> | Rc1/2 | 0.7 kg |
| 363-300-00BM | Rc3/8 | 63 <3.4> | 85 <4.6> | ||
| 363-400-00BM | Rc1/2 | 75 <4.0> | 100 <5.4> | ||
| 368-400-00BM | 106 <5.7> | 160 <8.6> | Rc1 | 1.4 kg | |
| 368-600-00BM | Rc3/4 | 170 <9.1> | 236 <12.7> | ||
| 368-800-00BM | Rc1 | 190 <10.2> | 250 <13.5> | ||
| 368-A00-00BM | Rc1 1/4 | 190 <10.2> | 250 <13.5> | Rc1 1/4 | |
| 36B-A00-00BM | 450 <24.3> | 530 <28.6> | Rc2 | 5.6 kg | |
| 36B-B00-00BM | Rc1 1/2 | 500 <27.0> | 600 <32.4> | ||
| 36B-C00-00BM | Rc2 | 530 <28.6> | 600 <32.4> | ||
●Two-position single solenoid normally open
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
EX port pipe connection threads | Weight (kg) | |
| IN - OUT | OUT - EX | ||||
| 363-200-10BM | Rc1/4 | 47.5 <2.6> | 56 <3.0> | Rc1/2 | 0.7 kg |
| 363-300-10BM | Rc3/8 | 60 <3.2> | 71 <3.8> | ||
| 363-400-10BM | Rc1/2 | 63 <3.4> | 71 <3.1> | ||
| 368-400-10BM | 112 <6.1> | 140 <7.6> | Rc1 | 1.4 kg | |
| 368-600-10BM | Rc3/4 | 150 <8.1> | 176 <9.5> | ||
| 368-800-10BM | Rc1 | 190 <10.3> | 180 <9.7> | ||
| 368-A00-10BM | Rc1 1/4 | 190 <10.3> | 180 <9.7> | Rc1 1/4 | |
| 36B-A00-10BM | 400 <21.6> | 425 <23.0> | Rc2 | 5.6 kg | |
| 36B-B00-10BM | Rc1 1/2 | 480 <25.9> | 500 <27.0> | ||
| 36B-C00-10BM | Rc2 | 480 <25.9> | 500 <27.0> | ||
Model No.
●Two-position type
| 36 | 3 | - | 2 | 00 | - | 0 | 0BM |
| Product name | [1] | [2] | [3] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Function
| 0 | Normally closed |
| 1 | Normally open |
Poppet Type Master Valve (4-Port) Model No. 46_-_00-_0BM
- High durability
- Flange connection that facilitates installation and removal of the unit
- The pipe connection direction can be switched.
- You can switch between the internal and external pilot methods.
- Can be used without an oil supply.
Standard specifications
| Operating fluid | Compressed air filtered by a filter | ||
| Operating pressure | Pressure range on the main valve side | 0.05-1.0 MPa | |
| Pilot pressure setting | Pressure range on the main valve side: 0.05-0.15 MPa | 0.15-0.3 MPa | |
| Pressure range on the main valve side: 0.15-1.0 MPa | From the pressure range on the main valve side to the pressure range on the main valve side + 0.3 MPa (However, ensure that 1.0 MPa is not exceeded.) |
||
| Withstand pressure | 1.6 MPa | ||
| Ambient temperature | 5-60°C | ||
| Lubrication | Lubrication required (ISO VG32 turbine oil or equivalent)* | ||
| Standard accessories | Installation bracket | ||
* Can be used even without an oil supply.
Typical characteristic values
●Two-position single pilot
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
EX port pipe connection threads | Weight (kg) | |||
| IN - OUT | OUT - EX | ||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | ||||
| 463-200-10BM | Rc1/4 | 42.5 <2.3> |
42.5 <2.3> |
53 <2.8> |
53 <2.8> |
Rc1/2 | 1.4 kg |
| 463-300-10BM | Rc3/8 | 56 <3.0> |
56 <3.0> |
67 <3.6> |
80 <4.3> |
||
| 463-400-10BM | Rc1/2 | 60 <3.2> |
67 <3.6> |
71 <3.8> |
90 <4.8> |
||
| 468-400-10BM | 112 <6.0> |
118 <6.3> |
150 <8.1> |
160 <8.6> |
Rc1 | 3.1 kg | |
| 468-600-10BM | Rc3/4 | 160 <8.6> |
170 <9.1> |
190 <10.2> |
180 <9.7> |
||
| 468-800-10BM | Rc1 | 180 <9.7> |
190 <10.2> |
190 <10.2> |
200 <10.8> |
||
| 468-A00-10BM | Rc1 1/4 | 180 <9.7> |
190 <10.2> |
190 <10.2> |
200 <10.8> |
Rc1 1/4 | |
| 46B-A00-10BM | 400 <21.6> |
450 <24.3> |
425 <22.9> |
530 <28.6> |
Rc2 | 10.9 kg | |
| 46B-B00-10BM | Rc1 1/2 | 480 <25.9> |
500 <27.0> |
500 <27.0> |
560 <30.2> |
||
| 46B-C00-10BM | Rc2 | 480 <25.9> |
530 <28.6> |
500 <27.0> |
560 <30.2> |
||
●Three-position multi pilot closed center
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
EX port pipe connection threads | Weight (kg) | |||
| IN - OUT | OUT - EX | ||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | ||||
| 463-200-30BM | Rc1/4 | 43 <2.3> |
43 <2.3> |
58 <3.1> |
56 <3.0> |
Rc1/2 | 2.5 kg |
| 463-300-30BM | Rc3/8 | 63 <3.4> |
63 <3.4> |
88 <4.7> |
73 <3.9> |
||
| 463-400-30BM | Rc1/2 | 76 <4.1> |
76 <4.1> |
100 <5.4> |
80 <4.3> |
||
| 468-400-30BM | 124 <6.7> |
124 <6.7> |
175 <9.4> |
150 <8.1> |
Rc1 | 4.5 kg | |
| 468-600-30BM | Rc3/4 | 175 <9.4> |
175 <9.4> |
250 <13.5> |
180 <9.7> |
||
| 468-800-30BM | Rc1 | 200 <10.8> |
200 <10.8> |
282 <15.2> |
195 <10.5> |
||
| 468-A00-30BM | Rc1 1/4 | 200 <10.8> |
200 <10.8> |
285 <15.4> |
186 <10.0> |
Rc1 1/4 | |
| 46B-A00-30BM | 540 <29.2> |
540 <29.2> |
590 <31.9> |
380 <20.5> |
Rc2 | 13.9 kg | |
| 46B-B00-30BM | Rc1 1/2 | 540 <29.2> |
540 <29.2> |
630 <34.0> |
380 <20.5> |
||
| 46B-C00-30BM | Rc2 | 545 <29.5> |
545 <29.5> |
680 <36.7> |
390 <21.1> |
||
●Three-position multi exhaust center
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
EX port pipe connection threads | Weight (kg) | |||
| IN - OUT | OUT - EX | ||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | ||||
| 463-200-40BM | Rc1/4 | 37 <2.0> |
37 <2.0> |
41 <2.2> |
40 <2.1> |
Rc1/2 | 2.0 kg |
| 463-300-40BM | Rc3/8 | 58 <3.1> |
58 <3.1> |
78 <4.2> |
65 <3.5> |
||
| 463-400-40BM | Rc1/2 | 70 <3.7> |
70 <3.7> |
104 <5.6> |
75 <4.0> |
||
| 468-400-40BM | 122 <6.5> |
122 <6.5> |
170 <9.1> |
130 <7.0> |
Rc1 | 3.7 kg | |
| 468-600-40BM | Rc3/4 | 170 <9.1> |
170 <9.1> |
245 <13.2> |
145 <7.8> |
||
| 468-800-40BM | Rc1 | 195 <10.5> |
195 <10.5> |
280 <15.1> |
150 <8.1> |
||
| 468-A00-40BM | Rc1 1/4 | 196 <10.5> |
196 <10.5> |
280 <15.1> |
150 <8.1> |
Rc1 1/4 | |
| 46B-A00-40BM | 450 <24.3> |
450 <24.3> |
540 <29.9> |
265 <14.3> |
Rc2 | 11.5 kg | |
| 46B-B00-40BM | Rc1 1/2 | 510 <27.6> |
510 <27.6> |
645 <34.9> |
270 <14.6> |
||
| 46B-C00-40BM | Rc2 | 525 <28.4> |
525 <28.4> |
680 <36.7> |
270 <14.6> |
||
●Three-position multi pressure center
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
EX port pipe connection threads | Weight (kg) | |||
| IN - OUT | OUT - EX | ||||||
| IN → 01 | IN → 02 | 01 → EX | 02 → EX | ||||
| 463-200-50BM | Rc1/4 | 35 <1.8> |
35 <1.8> |
40 <2.1> |
40 <2.1> |
Rc1/2 | 2.0 kg |
| 463-300-50BM | Rc3/8 | 50 <2.7> |
50 <2.7> |
66 <3.5> |
64 <3.4> |
||
| 463-400-50BM | Rc1/2 | 53 <2.8> |
53 <2.8> |
73 <3.9> |
70 <4.0> |
||
| 468-400-50BM | 120 <6.4> |
120 <6.4> |
153 <8.2> |
145 <7.8> |
Rc1 | 3.7 kg | |
| 468-600-50BM | Rc3/4 | 175 <9.4> |
175 <9.4> |
185 <10.0> |
170 <9.1> |
||
| 468-800-50BM | Rc1 | 190 <10.2> |
200 <10.8> |
200 <10.8> |
180 <9.7> |
||
| 468-A00-50BM | Rc1 1/4 | 184 <9.9> |
192 <10.3> |
198 <10.7> |
177 <9.5> |
Rc1 1/4 | |
| 46B-A00-50BM | 450 <24.3> |
460 <24.9> |
470 <25.4> |
450 <24.3> |
Rc2 | 11.5 kg | |
| 46B-B00-50BM | Rc1 1/2 | 510 <27.6> |
510 <27.6> |
515 <27.8> |
480 <25.9> |
||
| 46B-C00-50BM | Rc2 | 510 <27.6> |
510 <27.6> |
540 <29.2> |
500 <27.0> |
||
Model No.
●Two-position type
| 46 | 3 | - | 2 | 00 | - | 10BM |
| Product name | [1] | [2] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
●Three-position type
| 46 | 3 | - | 2 | 00 | - | 3 | 0BM |
| Product name | [1] | [2] | [3] |
[1]Basic body size
| 3 | 3/8B |
| 8 | 1B |
| B | 1 1/2B |
[2]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
| 8 | Rc1 |
| A | Rc1 1/4 |
| B | Rc1 1/2 |
| C | Rc2 |
[3]Function
| 3 | Closed center |
| 4 | Exhaust center |
| 5 | Pressure center |