PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)

Poppet Type Master Valve (2/3/4-Port)

Poppet Type Master Valve (2-Port) Model No. 26_-_00-_0BM

Model No. 26_-_00-_0BM
  • Poppet structure that facilitates maintenance
  • The pilot method achieves reliable operation.
  • Ideal as a switch valve for a large flow rate.
  • Normally closed and open valves are available.
  • Valve with superior durability
  • Can be used without an oil supply.

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure Pressure range on the main valve side 0.05-1.0 MPa
Pilot pressure setting Pressure range on the main valve side: 0.05-0.15 MPa 0.15-0.3 MPa
Pressure range on the main valve side: 0.15-1.0 MPa From the pressure range on the main valve side to the pressure range on the main valve side + 0.3 MPa
(However, ensure that 1.0 MPa is not exceeded.)
Withstand pressure 1.6 MPa
Ambient temperature 5-60°C
Lubrication Lubrication required (ISO VG32 turbine oil or equivalent)*
Standard accessories Installation bracket

* Can be used even without an oil supply.

Typical characteristic values

●Two-position single pilot normally closed

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Weight (kg)
IN - OUT
263-200-00BM Rc1/4 40 <2.2> 0.7 kg
263-300-00BM Rc3/8 58 <3.1>
263-400-00BM Rc1/2 71 <3.8>
268-400-00BM 112 <6.1> 1.4 kg
268-600-00BM Rc3/4 170 <9.2>
268-800-00BM Rc1 190 <10.2>
268-A00-00BM Rc1 1/4 190 <10.2>
26B-A00-00BM 450 <24.3> 5.6 kg
26B-B00-00BM Rc1 1/2 510 <27.5>
26B-C00-00BM Rc2 570 <30.8>

●Two-position single pilot normally open

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Weight (kg)
IN - OUT
263-200-10BM Rc1/4 40 <2.2> 0.7 kg
263-300-10BM Rc3/8 53 <2.9>
263-400-10BM Rc1/2 63 <3.4>
268-400-10BM 112 <6.1> 1.4 kg
268-600-10BM Rc3/4 165 <8.9>
268-800-10BM Rc1 190 <10.2>
268-A00-10BM Rc1 1/4 190 <10.2>
26B-A00-10BM 480 <25.9> 5.6 kg
26B-B00-10BM Rc1 1/2 550 <29.7>
26B-C00-10BM Rc2 600 <32.4>

Model No.

26 3 - 2 00 - 0 0BM
Product name [1] [2] [3]

[1]Basic body size

3 3/8B
8 1B
B 1 1/2B

[2]Pipe connection threads

2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4
8 Rc1
A Rc1 1/4
B Rc1 1/2
C Rc2

[3]Function

0 Normally closed
1 Normally open

Poppet Type Master Valve (3-Port) Model No. 36_-_00-_0BM

Model No. 36_-_00-_0BM
  • Poppet structure that facilitates maintenance
  • The pilot method achieves reliable operation.
  • Ideal as a switch valve for a large flow rate.
  • Normally closed and open valves are available.
  • Valve with superior durability
  • Can be used without an oil supply.

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure Pressure range on the main valve side 0.05-1.0 MPa
Pilot pressure setting Pressure range on the main valve side: 0.05-0.15 MPa 0.15-0.3 MPa
Pressure range on the main valve side: 0.15-1.0 MPa From the pressure range on the main valve side to the pressure range on the main valve side + 0.3 MPa
(However, ensure that 1.0 MPa is not exceeded.)
Withstand pressure 1.6 MPa
Ambient temperature 5-60°C
Lubrication Lubrication required (ISO VG32 turbine oil or equivalent)*
Standard accessories Installation bracket

* Can be used even without an oil supply.

Typical characteristic values

●Two-position single pilot normally closed

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
363-200-00BM Rc1/4 42.5 <2.3> 56 <3.0> Rc1/2 0.7 kg
363-300-00BM Rc3/8 63 <3.4> 85 <4.6>
363-400-00BM Rc1/2 75 <4.0> 100 <5.4>
368-400-00BM 106 <5.7> 160 <8.6> Rc1 1.4 kg
368-600-00BM Rc3/4 170 <9.1> 236 <12.7>
368-800-00BM Rc1 190 <10.2> 250 <13.5>
368-A00-00BM Rc1 1/4 190 <10.2> 250 <13.5> Rc1 1/4
36B-A00-00BM 450 <24.3> 530 <28.6> Rc2 5.6 kg
36B-B00-00BM Rc1 1/2 500 <27.0> 600 <32.4>
36B-C00-00BM Rc2 530 <28.6> 600 <32.4>

●Two-position single solenoid normally open

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
363-200-10BM Rc1/4 47.5 <2.6> 56 <3.0> Rc1/2 0.7 kg
363-300-10BM Rc3/8 60 <3.2> 71 <3.8>
363-400-10BM Rc1/2 63 <3.4> 71 <3.1>
368-400-10BM 112 <6.1> 140 <7.6> Rc1 1.4 kg
368-600-10BM Rc3/4 150 <8.1> 176 <9.5>
368-800-10BM Rc1 190 <10.3> 180 <9.7>
368-A00-10BM Rc1 1/4 190 <10.3> 180 <9.7> Rc1 1/4
36B-A00-10BM 400 <21.6> 425 <23.0> Rc2 5.6 kg
36B-B00-10BM Rc1 1/2 480 <25.9> 500 <27.0>
36B-C00-10BM Rc2 480 <25.9> 500 <27.0>

Model No.

●Two-position type

36 3 - 2 00 - 0 0BM
Product name [1] [2] [3]

[1]Basic body size

3 3/8B
8 1B
B 1 1/2B

[2]Pipe connection threads

2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4
8 Rc1
A Rc1 1/4
B Rc1 1/2
C Rc2

[3]Function

0 Normally closed
1 Normally open

Poppet Type Master Valve (4-Port) Model No. 46_-_00-_0BM

Model No. 46_-_00-_0BM
  • High durability
  • Flange connection that facilitates installation and removal of the unit
  • The pipe connection direction can be switched.
  • You can switch between the internal and external pilot methods.
  • Can be used without an oil supply.

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure Pressure range on the main valve side 0.05-1.0 MPa
Pilot pressure setting Pressure range on the main valve side: 0.05-0.15 MPa 0.15-0.3 MPa
Pressure range on the main valve side: 0.15-1.0 MPa From the pressure range on the main valve side to the pressure range on the main valve side + 0.3 MPa
(However, ensure that 1.0 MPa is not exceeded.)
Withstand pressure 1.6 MPa
Ambient temperature 5-60°C
Lubrication Lubrication required (ISO VG32 turbine oil or equivalent)*
Standard accessories Installation bracket

* Can be used even without an oil supply.

Typical characteristic values

●Two-position single pilot

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-200-10BM Rc1/4 42.5
<2.3>
42.5
<2.3>
53
<2.8>
53
<2.8>
Rc1/2 1.4 kg
463-300-10BM Rc3/8 56
<3.0>
56
<3.0>
67
<3.6>
80
<4.3>
463-400-10BM Rc1/2 60
<3.2>
67
<3.6>
71
<3.8>
90
<4.8>
468-400-10BM 112
<6.0>
118
<6.3>
150
<8.1>
160
<8.6>
Rc1 3.1 kg
468-600-10BM Rc3/4 160
<8.6>
170
<9.1>
190
<10.2>
180
<9.7>
468-800-10BM Rc1 180
<9.7>
190
<10.2>
190
<10.2>
200
<10.8>
468-A00-10BM Rc1 1/4 180
<9.7>
190
<10.2>
190
<10.2>
200
<10.8>
Rc1 1/4
46B-A00-10BM 400
<21.6>
450
<24.3>
425
<22.9>
530
<28.6>
Rc2 10.9 kg
46B-B00-10BM Rc1 1/2 480
<25.9>
500
<27.0>
500
<27.0>
560
<30.2>
46B-C00-10BM Rc2 480
<25.9>
530
<28.6>
500
<27.0>
560
<30.2>

●Three-position multi pilot closed center

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-200-30BM Rc1/4 43
<2.3>
43
<2.3>
58
<3.1>
56
<3.0>
Rc1/2 2.5 kg
463-300-30BM Rc3/8 63
<3.4>
63
<3.4>
88
<4.7>
73
<3.9>
463-400-30BM Rc1/2 76
<4.1>
76
<4.1>
100
<5.4>
80
<4.3>
468-400-30BM 124
<6.7>
124
<6.7>
175
<9.4>
150
<8.1>
Rc1 4.5 kg
468-600-30BM Rc3/4 175
<9.4>
175
<9.4>
250
<13.5>
180
<9.7>
468-800-30BM Rc1 200
<10.8>
200
<10.8>
282
<15.2>
195
<10.5>
468-A00-30BM Rc1 1/4 200
<10.8>
200
<10.8>
285
<15.4>
186
<10.0>
Rc1 1/4
46B-A00-30BM 540
<29.2>
540
<29.2>
590
<31.9>
380
<20.5>
Rc2 13.9 kg
46B-B00-30BM Rc1 1/2 540
<29.2>
540
<29.2>
630
<34.0>
380
<20.5>
46B-C00-30BM Rc2 545
<29.5>
545
<29.5>
680
<36.7>
390
<21.1>

●Three-position multi exhaust center

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-200-40BM Rc1/4 37
<2.0>
37
<2.0>
41
<2.2>
40
<2.1>
Rc1/2 2.0 kg
463-300-40BM Rc3/8 58
<3.1>
58
<3.1>
78
<4.2>
65
<3.5>
463-400-40BM Rc1/2 70
<3.7>
70
<3.7>
104
<5.6>
75
<4.0>
468-400-40BM 122
<6.5>
122
<6.5>
170
<9.1>
130
<7.0>
Rc1 3.7 kg
468-600-40BM Rc3/4 170
<9.1>
170
<9.1>
245
<13.2>
145
<7.8>
468-800-40BM Rc1 195
<10.5>
195
<10.5>
280
<15.1>
150
<8.1>
468-A00-40BM Rc1 1/4 196
<10.5>
196
<10.5>
280
<15.1>
150
<8.1>
Rc1 1/4
46B-A00-40BM 450
<24.3>
450
<24.3>
540
<29.9>
265
<14.3>
Rc2 11.5 kg
46B-B00-40BM Rc1 1/2 510
<27.6>
510
<27.6>
645
<34.9>
270
<14.6>
46B-C00-40BM Rc2 525
<28.4>
525
<28.4>
680
<36.7>
270
<14.6>

●Three-position multi pressure center

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-200-50BM Rc1/4 35
<1.8>
35
<1.8>
40
<2.1>
40
<2.1>
Rc1/2 2.0 kg
463-300-50BM Rc3/8 50
<2.7>
50
<2.7>
66
<3.5>
64
<3.4>
463-400-50BM Rc1/2 53
<2.8>
53
<2.8>
73
<3.9>
70
<4.0>
468-400-50BM 120
<6.4>
120
<6.4>
153
<8.2>
145
<7.8>
Rc1 3.7 kg
468-600-50BM Rc3/4 175
<9.4>
175
<9.4>
185
<10.0>
170
<9.1>
468-800-50BM Rc1 190
<10.2>
200
<10.8>
200
<10.8>
180
<9.7>
468-A00-50BM Rc1 1/4 184
<9.9>
192
<10.3>
198
<10.7>
177
<9.5>
Rc1 1/4
46B-A00-50BM 450
<24.3>
460
<24.9>
470
<25.4>
450
<24.3>
Rc2 11.5 kg
46B-B00-50BM Rc1 1/2 510
<27.6>
510
<27.6>
515
<27.8>
480
<25.9>
46B-C00-50BM Rc2 510
<27.6>
510
<27.6>
540
<29.2>
500
<27.0>

Model No.

●Two-position type

46 3 - 2 00 - 10BM
Product name [1] [2]

[1]Basic body size

3 3/8B
8 1B
B 1 1/2B

[2]Pipe connection threads

2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4
8 Rc1
A Rc1 1/4
B Rc1 1/2
C Rc2

●Three-position type

46 3 - 2 00 - 3 0BM
Product name [1] [2] [3]

[1]Basic body size

3 3/8B
8 1B
B 1 1/2B

[2]Pipe connection threads

2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4
8 Rc1
A Rc1 1/4
B Rc1 1/2
C Rc2

[3]Function

3 Closed center
4 Exhaust center
5 Pressure center
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS