PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)

Direct-Acting Solenoid Valve (3/5-Port)

Direct-Acting Solenoid Valve (3-Port) Model No. MVS-303

Model No. MVS-303
  • Direct-acting air pressure three-way valve that directly applies the force of a magnet (electromagnetic force) to the valve to switch the air passage
  • Operating only with an electromagnetic force, the valve can also be used in a low pressure circuit close to 0 MPa.
  • In-line direct-acting solenoid valve
  • Can be used without an oil supply.
  • High response speed and stability

Standard specifications

Valve function Direct-acting solenoid valve (3-Port), single solenoid normally closed
Operating fluid Compressed air filtered by a filter
Operating pressure range 0-1.0 MPa
Lubrication ISO VG32 turbine oil*
Ambient temperature 5-50°C
Manual operations Non-locking type manual push button
Restriction on the installation direction None
Rated voltage ・AC 100 V 50 Hz, AC 110 V 60 Hz
・AC 200 V 50 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

* Can be used even without an oil supply.

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.510 A 0.435 A
AC 200 V 0.260 A 0.220 A
Holding current AC 100 V 0.240 A 0.192 A
AC 200 V 0.120 A 0.096 A
Direct current DC 24 V 0.54 A

Typical characteristic values

Model No. Pipe connection threads Response time* (msec) Weight (kg) Effective cross-sectional area (mm²) < Cv value >
ON OFF IN - OUT OUT - EX
MVS-303-02Y  Rc1/4 6 8 0.7 7 <0.38> 7.5 <0.40>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Model No.

MVS-303 - 02Y H R DC24V
Product name [1] [2] [3]

[1]Voltage type

Blank AC
H DC

[2]Accessories

Blank Non-locking type manual push button
R Locking type manual push button
S Indicator lamp and surge killer

[3]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

Direct-Acting Solenoid Valve (3-Port) Model No. 392-_00

Model No. 392-_00
  • In-line connection model (Rc1/4, Rc3/8)
  • Universal port for which the valve function can be selected according to use
  • The models for compressed air and vacuum are available.
  • The installation bracket is included.
  • Operating pressure: 0-0.7 MPa (for compressed air), 0.1-0 MPa (for vacuum)
  • Rated voltage: AC 100/200 V (50/60 Hz), DC 24 V

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range For compressed air 0-0.7 MPa
For vacuum −0.1-0 MPa
Ambient temperature 5-50°C
Lubrication Not required
Manual operations Non-locking type push button
Restriction on the installation direction None
Ratings of the solenoid Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.205 A 0.176 A
AC 200 V 0.103 A 0.088 A
Holding current AC 100 V 0.180 A 0.146 A
AC 200 V 0.088 A 0.072 A
Direct current DC 24 V 0.430 A

Typical characteristic values

Model No. Pipe connec-tion threads Effective cross-sectional area
(mm²)
Response time*
(msec)
Weight
(kg)
For compressed air (0-0.7 MPa) For vacuum (−0.1-0 MPa)
Standard model Indicator lamp
With surge killer
Standard model Indicator lamp
With surge killer
ON OFF
392-200-60B1 392-200-60B4 392-200-02B1 392-200-02B4 Rc1/4 11 7 6.5 0.5
392-300-60B1 392-300-60B4 392-300-02B1 392-300-02B4 Rc3/8

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Model No.

392 - 2 00 - 60 B 1 AC100V
Product name [1] [2] [3] [4] [5]

[1]Pipe connection threads

2 Rc1/4
3 Rc3/8

[2]Function

60 Compressed air, universal port model
02 Vacuum, normally closed model

[3]Inclusion of the bracket

B With bracket
0 Without bracket

[4]Electrical connection

1 DIN connector
4 With DIN connector and indicator lamp

[5]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

Direct-Acting Solenoid Valve (5-Port) Model No. MVS/D-490_

Model No. MVS/D-490_
  • The direct-acting spool valve has good responsiveness and can operate frequently.
  • The newly developed solenoid further improves durability.
  • No air loss

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range 0-1.0 MPa
Ambient temperature 5-50°C
Lubrication ISO VG32 turbine oil
Manual operations Non-locking type push button
Restriction on the installation direction None
Ratings of the solenoid Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.750 A 0.630 A
AC 200 V 0.380 A 0.335 A
Holding current AC 100 V 0.240 A 0.192 A
AC 200 V 0.120 A 0.096 A
Direct current DC 24 V 0.540 A

Typical characteristic values

Valve function Pipe connection threads Model No. Effective cross-sectional area
(mm²)
Response time
(msec)
Weight
For alternate current and direct current (kg)
Standard model
(for alternate current)
Indicator lamp
With surge killer
(for alternate current)
For direct current ON OFF
Single solenoid Rc1/4 MVS-4902 MVS-4902S MVS-4902H 9 8 11 1.0/1.4
Rc3/8 MVS-4903 MVS-4903S MVS-4903H
Single solenoid Rc1/4 MVD-4902 MVD-4902S MVD-4902H - 1.3/2.1
Rc3/8 MVD-4903 MVD-4903S MVD-4903H

Model No.

MV S - 49 02 H R DC24V
[1] [2] [3] [4] [5]

[1]Number of solenoids

S Single solenoid
D Double solenoid

[2]Pipe connection threads

02 Rc1/4
03 Rc3/8

[3]Voltage type

Blank AC
H DC

[4]Accessories

Blank Non-locking type manual push button
R Locking type manual push button
S Indicator lamp and surge killer

[5]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS