PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)

Diaphragm Type Solenoid Valve (2-Port)

Model No. MVS-220_Y, Model No. MVS-23_ _Y

Model No. MVS-220_Y、MVS-23_ _Y
  • Diaphragm type with a large flow rate
  • Can be used for water and liquids with a low viscosity.
  • Can be used without an oil supply.
  • DIN-terminal connection method
  • Can be used to turn ON or OFF the vacuum circuit.

Standard specifications

Use For compressed air For liquid*1
Operating fluid Compressed air filtered by a filter Water or liquid with a low viscosity
Operating pressure range 0.02-0.70 MPa 0.15-0.70 MPa
Ambient temperature 5-50°C
Lubrication Not required
Manual operations None
Rated voltage ・AC 100 V 50/60 Hz, AC 110 V 60 Hz
・AC 200 V 50/60 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10%
Insulation type Type B

*1. The model for liquid is the same basic model as that for compressed air. Use non-corrosive fluid with a low viscosity.

Notes:

  • Vertically install the solenoid valve for vacuum and for compressed air with a low operating pressure of 0.02 to 0.15 MPa.

Current value of the solenoid

- Voltage/frequency 50 Hz 60 Hz
Striking current AC 100 V 0.126 A 0.100 A
AC 200 V 0.060 A 0.049 A
Holding current AC 100 V 0.104 A 0.084 A
AC 200 V 0.050 A 0.041 A
Direct current DC 24 V 0.490 A

Notes:

  • For other voltages, contact Azbil TA Co., Ltd.

Typical characteristic values

Model No. Pipe connection threads Response time*
(msec)
Weight (kg) Effective cross-sectional area (mm²)
< Cv value >
For compressed air and liquid ON OFF
MVS-2202Y Rc1/4 9.6 10.4 0.5 35 <1.9>
MVS-2203Y Rc3/8 40 <2.2>
MVS-2204JY Rc1/2
MVS-2304Y 12.4 20.2 1.5 110 <5.9>
MVS-2306Y Rc3/4 170 <9.2>
MVS-2310Y Rc1 240 <13.0>
MVS-2312JY Rc1 1/4 350 <18.9>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Model No.

●Model No. MVS-220_Y

MVS-220 2 Y H V S B DC24V
Product name [1] [2] [3] [4] [5] [6]

[1]Pipe connection threads

2 Rc1/4
3 Rc3/8
4J Rc1/2 (overport)

[2]Voltage type

Blank AC
H DC

[3]Use

Blank For compressed air and liquid
V For vacuum

[4]Accessories

Blank No accessories
S With DIN terminal, indicator lamp, and surge killer

[5]Inclusion of the bracket

Blank Without bracket
B With bracket

[6]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

●Model No. MVS-23_ _Y

MVS-23 04 Y H V S B DC24V
Product name [1] [2] [3] [4] [5] [6]

[1]Pipe connection threads

04 Rc1/2
06 Rc3/4
10 Rc1
12J Rc1 1/4 (overport)

[2]Voltage type

Blank AC
H DC

[3]Use

Blank For compressed air and liquid
V For vacuum

[4]Accessories

Blank No accessories
S With DIN terminal, indicator lamp, and surge killer

[5]Inclusion of the bracket

Blank Without bracket
B With bracket

[6]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS