PRODUCTSAUXILIARY CIRCUIT COMPONENTS

Pop-Type Relief Valve

Model No. NSV-30_

Model No. NSV-30_
  • Allows you to set various relief pressures.
  • The steel ball opens the valve seat and the valve fully opens at once.
  • You can manually exhaust air.
  • Can be directly screwed in without using nipples.
  • Compact with a small footprint

Standard specifications

Operating fluid Compressed air filtered by a filter
Maximum operating pressure 1.4 MPa
Operating temperature 5-60°C

Typical characteristic values

Setting range of the relief pressure (MPa) and model No. Pipe connection threads Weight (kg)
0.31-0.7
(standard)
NSV-301 Rc1/8 0.15
NSV-302 Rc1/4 0.16
NSV-303 Rc3/8 0.16
NSV-304 Rc1/2 0.18

Notes:

  • The products are set to the relief pressure at the upper limit of the set pressure range at shipment.

Model No.

NSV-3 01 K0.7 R
Product name [1] [2] [3]

[1]Pipe connection threads

01 Rc1/8
02 Rc1/4
03 Rc3/8
04 Rc1/2

[2]Pressure adjustment range

Set pressure range
(MPa)
Pressure set in advance
(MPa)
Blowoff pressure
(MPa)
Dead-end pressure
(MPa)
Blank 0.31-0.70 0.70 0.70±0.02 70% or more of the pressure set in advance
K0.7 0.06-0.10 0.07 0.09 or less
K1.5 0.11-0.15 0.15 0.15±0.02
K3 0.16-0.30 0.30 0.30±0.02
K10 0.71-1.0 1.0 1.0±0.1
K14 0.71-1.4 1.4 1.4±0.1
S_ Set to the specified pressure.*
F_ Set to the specified pressure.*

*The products can also be delivered with the specified pressure preset.

・When presetting the specified pressure in the resettable state, add S to the end of the standard Model No. and enter the set pressure after that.

・When presetting the specified pressure in the unresettable state, add F to the end of the standard Model No. and enter the set pressure after that.
(Example) Model No. NSV-30_ F4.0 when using the product in the unresettable state with the relief pressure set to 0.4 MPa

[3]Inclusion of a pull ring

Blank Without pull ring
R With pull ring
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS