| FLUID | Compressed Air | Liquid* | Vacuum |
| OPERATING PRESSURE RANGE | 0.02 ~ 0.7MPa | 0.15 ~ 0.7MPa | – 0.08 ~ 0MPa |
| AMBIENT TEMPERATURE | 5 ~ 50°C | ||
| LUBRICANT | Required | ||
| MANUAL OPERATION | Nil | ||
| RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
||
| VOLTAGE ALLOWANCE | –15 ~ 10% | ||
| INSULATION GRADE | Class B | ||
* Use non-corrosive and low viscosity liquid.
BASIC MODEL NOs. & OTHER SPECIFICATIONS
| Pipe Size |
MODEL NUMBER | Effective Area [mm²] < Cv value > |
||
| Single Solenoid Normally Closed | Mass [kg] |
|||
| Compressed Air / Liquid | Vacuum | |||
| Rc 1/4 | MVS-2202Y | MVS-2202YV | 0.5 | 35 < 1.9 > |
| Rc 3/8 | MVS-2203Y | MVS-2203YV | 40 < 2.2 > | |
| Rc 1/2 | MVS-2204JY | MVS-2204JYV | ||
| Pipe Size |
MODEL NUMBER | Effective Area [mm²] < Cv value > |
||
| Single Solenoid Normally Closed | Mass [kg] |
|||
| Compressed Air / Liquid | Vacuum | |||
| Rc 1/2 | MVS-2304Y | MVS-2304YV | 1.5 | 110 < 5.9 > |
| Rc 3/4 | MVS-2306Y | MVS-2306YV | 170 < 9.2 > | |
| Rc1 | MVS-2310Y | MVS-2310YV | 240 < 13.0 > | |
| Rc1 1/4 | MVS-2312JY | MVS-2312JYV | 350 < 18.9 > | |