| Operating Fluid*1 | Clean and dry compressed air(Please use an oil mist separator) | |
| Operating Pressure Range | 0.15 ~ 0.35MPa | |
| Manifold Pressure Range | 0.05 ~ 0.25MPa | |
| Endurable Pressure | 0.5MPa | |
| Ambient Temperature | 5 ~ 50℃ | |
| Port Size | IN | Rc3/8 |
| OUT | Rc1/2 | |
| Air Consumption*2 | MAX. 500dm³/min(ANR) | |
| Lubricant | ISO VG32 ~ 68(Suitable for mist lubrication) | |
| Available Oil Shots Range | MC9-01L3 | 1 ~ 20shots/min(0.05cm³/shot) |
| MC9-01D2 | 1shot/3min ~ 10shots/min(0.015cm³/shot) | |
| Oil Tank Capacity | 1,000cm³(Effective capacity :800cm³) | |
| Rated Voltage | ・AC100V ・AC200V ・DC24V |
|
| Mass | MC9-01L3 | 3.5kg |
| MC9-01D2 | 3.6kg | |
*1. For general lubrication purposes, compressed air quality class 2: 6: 3 or higher according to JIS B 8392-1;
for precise bearing lubrication, compressed air quality class 1: 6: 3 or higher according to JIS B 8392-1 use compressed air.
*2. Air consumption varies with manifold pressure and number of nozzles.
※ During the operation of this unit, please maintain a viscosity range of 10 to 150 cSt.
※ Please use lubricating oil that has atomization characteristics suitable for mist lubrication and is specified or recommended
by the machine or bearing manufacturer.
※ We recommend lubricating oils with a viscosity grade of ISO VG32 to 68.
If using oils with viscosities outside the above range, please use brands and grades suitable for micron lube lubrication.
| MC9 | - | 01 | □□ | - | □ | B | □ | □ | K□.□/K□.□ |
| Product Name | [1] | [2] | [3] | [4] | [5] | [6] |
[1]Operation Method/Pump Discharge Capacity
| L3 | Standard type/0.05cm³ |
| D2 |
Circulation type/0.015 cm³ |
[2]Rated Voltage
| 1 | AC100V 50/60Hz、AC110V 60Hz |
| 2 | AC200V 50/60Hz、AC220V 60Hz |
| 3 | DC24V |
[3]Air Control Equipment and Others
| B | Nil |
| T | Nil、TUV certified product |
[4]Attachment of Oil Feed Monitor and Electrical Control Circuit Board
| A | No oil feed monitor/Control circuit |
| C | With oil feed monitor/Control circuit |
[5]Specifications of Pressure Switch
| - | Operating Pressure Side | Manifold Pressure Side |
| 3 | Contact type | Contact type |
| 6 | Contactless type(NPN) | Contactless type(NPN) |
| 9 | Contactless type(PNP) | Contactless type(PNP) |
[6]Setting Pressure Indication of Pressure Switch
| - | Supply Pressure Switch | Manifold Pressure Switch |
| Nil | 0.10MPa | 0.05MPa |
| 2.0/1.0 | 0.20MPa | 0.10MPa |
| 2.5/1.5 | 0.25MPa | 0.15MPa |
※ The TUV certified product is MC9-01L3-3TA9 only. Other combinations cannot be specified.
※ Models with control circuits are only MC9-01L3-3BC6 and MC9-01D2-3BC6.
Other combinations cannot be specified.
※ Includes manifold pressure gauge and oil level switch.
※ The CPL MICRONLUB Lubrication Unit requires a twin timer, programmable controller,
or similar devices to drive the plunger pump for oil drop.
Please prepare these items in advance(Except for models with control circuits).
Please configure the control circuit for the lubrication system on the user side.
| Operating Fluid*1 | Clean and dry compressed air | |
| Maximum Operating Pressure | ・0.5MPa ・0.95MPa |
|
| Operating Pressure Range | 0.13MPa ~ 0.5MPa | |
| Manifold Pressure Range | 0.03MPa ~ 0.4MPa | |
| Ambient Temperature | 5 ~ 50℃ | |
| Port Size | IN | Rc3/8 |
| OUT | Rc1/2 | |
| Air Consumption | Max.500dm³/min(ANR) | |
| Lubricant*3 | ISO VG32 ~ VG68 | |
| Available Oil Shots Range | 1~20 shot/min | |
| Pump Output Volume | 0.025cm³/cycles、0.1cm³/cycles | |
| Oil tank Capacity | 1,000cm³(Effective capacity :800cm³) | |
| Electrical Capacity of Level Switch | Maximum Contact Capacity | 50VA/AC、50W/DC |
| Maximum Operating Current | 0.5A | |
| Maximum Operating Voltage | 300V AC/DC | |
| Rated Voltage | ・AC100V 50/60Hz、AC110V 60Hz ・AC200V 50/60Hz、AC220V 60Hz ・DC24V |
|
| Power Consumption | 30VA | |
| Operating Current of The Solenoid Valve | Pump-Driven Solenoid Valve PV |
AC100V:0.04A AC200V:0.25A DC24V:0.08A |
| Air Supply Solenoid Valve SOL |
AC100V:0.04A AC200V:0.25A DC24V:0.08A |
|
| Mass | 9.5kg | |
*1. We recommend using compressed air conditioned to at least quality class 2.6.3 according to ISO 8573-1.
*2. The airflow rate varies with the manifold pressure and the number of nozzles.
*3. Please use lubricating oil with atomization properties suitable for mist lubrication,
as specified or recommended by the machine or bearing manufacturers.
*3. We recommend lubricating oil with a viscosity grade of ISO VG32 to 68.
If using oils with viscosities outside the above range, please use brands and grades suitable for micron lube lubrication.
| MC5 | - | 02H | 2 | - | 1 | A | 11Y |
| Product Name | [1] | [2] | [3] | [4] | [5] |
[1]Tank and Refueling
| 02H | Basic model (operation stops during refueling) |
| A2L | Refueling possible during operation (manifold pressure is limited to a maximum of 0.2 MPa) |
[2]Pump Discharge Capacity
| 2 | 0.025cm³/cycles(Basic Plunger pump) |
| 4 | 0.1cm³/cycles(High-capacity plunger pump) |
[3]Rated Voltage
| 1 | AC100V 50/60Hz、AC110V 60Hz |
| 2 | AC200V 50/60Hz、AC200V 60Hz |
| 3 | DC24V |
[4]Accessories
| A | With oil feed monitor |
| S | Nil |
| T | With discharge pump drive control timer |
※ When the basic model is equipped with a control circuit board,
the installation positions of the pressure switch become "75Y" or "85Y."
[5]Installation Position of The Pressure Switch
| 11Y | OUT side of the air supply solenoid valve |
| 75Y | OUT side of the air supply solenoid valve、 With control circuit board*1 75Y/85Y:Refueling during operation with a sub-tank*2 79Y/82Y:Automatic refueling via solenoid valve*2 |
| 79Y | |
| 82Y | |
| 85Y | |
| 01Y | IN side of the air supply solenoid valve |
*1. The rated voltage is only AC 100V or DC 24V.
*2. [1]This applies when the tank and refueling are "A2L."
※ The pressure switch is mounted on the OUT side of the air supply solenoid valve, except for model 01Y.
Pressure detection occurs after the air supply solenoid valve is activated, and a pressure deficiency signal may occur due to
the delay in pressure detection. Therefore, please pay attention to the circuit configuration.
※ The 01Y pressure switch uses a mechanical contact type, while the 75Y/79Y/82Y/85Y models with control circuit boards
use a PNP solid-state type.