azbil

HOME > TOP > PRODUCT INFORMATION > DUAL VALVE > Dual Valve

Dual Valve

Model No. TX-A

Model NO. TX-A
  • Adopting a cross-flow design has achieved
    the lowest residual pressure in its class.
  • Unique pilot valve structure minimizes the risk
    of delayed OFF operation caused by oil.
  • Features the same mounting pitch as model MVS-35□□YC,
    allowing for immediate replacement.
  • A pressure switch can be installed on the standard monitoring port.
  • Complies with EU regulations (CE marking)
  • Awarded the Good Design Award in 2021.
図面CADデータ

SPECIFICATIONS

Operating Fluid Air
Switching Method Normally closed
Operation Internal pilot
Operating Pressure Range 0.2 ~ 0.7MPa
Ambient Temperature 5 ~ 50℃
Lubrication Unnecessary
Manual Operation Available
Mass TX-A040/06J:2.3kg TX-A060/100:3.5kg

FLOW CHARACTERISTICS

Model No. Pipe size Port(IN→OUT) Port(OUT→EX)
IN, OUT Port EX Port S[mm²] Cv S[mm²] Cv
TX-A040 Rc1/2 Rc3/4 40 2.1 170 9.2
TX-A06J Rc3/4 Rc3/4 40 2.1 206 11.1
TX-A060 Rc3/4 Rc1 1/4 63 3.4 307 16.6
TX-A100 Rc1 Rc1 1/4 63 3.4 393 21.3

SOLENOID SPECIFICATIONS

Electrical Wiring DIN-type terminal
DIN EN 175 301-803-A (DIN 43650)
Rated Voltage AC100V 50/60Hz、AC110V 60Hz
AC200V 50/60Hz、AC220V 60Hz
AC110V 50Hz
AC220V 50Hz
DC24V
Allowable Voltage Fluctuation -10% to +10% of rated voltage
Power Consumption*1 AC100V 50/60Hz, AC110V 60Hz 19VA
AC200V 50/60Hz, AC220V 60Hz 16VA
AC110V 50Hz 19VA
AC220V 50Hz 14VA
DC24V 7W

*1.The power is the value per solenoid.

MODEL NO.

TX-A 040 NN 11 0
Product Name [1] [2]

[1]Pipe size

- IN, OUT Port EX Port
040 Rc1/2 Rc3/4
06J Rc3/4 Rc3/4
060 Rc3/4 Rc1 1/4
100 Rc1 Rc1 1/4

[2]Rated Voltage

11 AC100V 50/60Hz, AC110V 60Hz
12 AC200V 50/60Hz, AC220V 60Hz
14 AC110V 50Hz
16 AC220V 50Hz
33 DC24V

 

Model No. MVS-35□□YC

Model No. MVS-35□□YC
  • High-frequency and stable operation is made possible by the short-stroke poppet main valve.
  • Complies with EU regulations (CE marking)
    ※Some models may be excluded.
図面CADデータ

SPECIFICATIONS

Operating Fluid Filtered compressed air
Operating Pressure Range Internal pilot air supply type 0.15 ~ 0.8MPa
External pilot air supply type 0.05 ~ 0.8MPa
Ambient temperature 5 ~ 50℃
Lubrication ISO VG 32 Turbine Oil
Manual Operation Non-locking type
The Rating of The Solenoid Rated Voltage ・AC100V 50/60Hz、AC110V 60Hz
・AC200V 50/60Hz、AC220V 60Hz
・DC24V
Allowable Voltage Variation ±10%
Insulation Class B

Solenoid current value

- Voltage/Frequency 50Hz 60Hz
Starting Current AC100V 1.02A 0.87A
AC200V 0.52A 0.44A
Holding Current AC100V 0.48A 0.384A
AC200V 0.24A 0.192A

REPRESENTATIVE CHARACTERISTICS

Model No.(Monitor/Mass(kg)) Pipe Connection Thread Effective Cross-Sectional Area(mm²)< Cv Value >
Without monitor Mass Limit Switch Type Proximity Switch Type Mass IN → OUT OUT → EX
MVS-3512YC 7.5 MVS-3512YCL - 8.8 Rc1 1/4 190 <10.3> 960 <51.9>
MVS-3514YC MVS-3514YCL - Rc1 1/2 190 <10.3> 1,140 <61.6>
MVS-3520FYC 12 - MVS-3520FYCK 17 Rc2 574 <31.1> 1,596 <86.5>

MODEL NO.

MVS-35 12 - YC G L H P S DC24V
Product Name [1] [2] [3] [4] [5] [6] [7]

[1]Pipe Size

IN、OUT Port EX Port
12 Rc1 1/4 Rc2
14 Rc1 1/2
20F Rc2 Rc2 1/2

[2]Inclusion of a Junction Box

Nil Without junction box
G With junction box

[3]Presence of Operation Monitor(Main Valve Section)

Nil Without operation monitor
K With AC proximity switch*1
L With limit switch

*1.   The AC proximity switch is only available for the MVS-3520F.

[4]Types of Voltage(Solenoid)

Nil AC
H DC

[5]Pilot Air Supply Type

Nil Internal pilot air supply type
P External pilot air supply type

[6]Inclusion of Indicator Light(Solenoid)

Nil Without indicator light
S With indicator light

[7]Rated Voltage

AC100V AC100V 50/60Hz、AC110v 60Hz
AC200V AC200V 50/60Hz、AC220V 60Hz
DC24V DC24V

※If a voltage other than the above is required, please specify the voltage and frequency.

©2000- Azbil TA Co., Ltd. All rights reserved.