5-PORT SPOOL OPERATED MASTER VALVE |
4-PORT POPPET OPERATED MASTER VALVE |
3-PORT POPPET OPERATED MASTER VALVE |
2-PORT POPPET OPERATED MASTER VALVE |
5-PORT PILOT VALVE | HAND VALVE |
![]() MVM-495 SERIES |
![]() MVM-492 SERIES 1/4B base |
![]() 524-M SERIES 1/2B base |
![]() MVM-491 SERIES 1B base |
![]() MVM-491 SERIES 1-1/2B base |
SPECIFICATIONS
FLUID | Filtered Compressed Air | |
OPERATING PRESSURE | 0.2 ~1.0MPa | |
Main pressure range |
0.2 ~1.0MPa | |
Pilot pressure range |
Same to pressure of main valve or higher. | |
AMBIENT TEMPERATURE | 5 ~ 60°C | |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | |
OPERATING PRESSURE | 0.2 ~1.0MPa | |
Main pressure range |
0.2 ~1.0MPa | |
Pilot pressure range |
Same to pressure of main valve or higher. | |
AMBIENT TEMPERATURE | 5 ~ 60°C | |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | ||
OPERATING PRESSURE | 0 ~1.0MPa | ||
Main pressure range |
0 ~0.2MPa | 0.2 ~1.0MPa | |
Pilot pressure range |
0.2 ~0.3MPa | Same to pressure of main valve or higher. |
|
AMBIENT TEMPERATURE | 5 ~ 60°C | ||
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | |
OPERATING PRESSURE | 0.15 ~1.0MPa | |
Main pressure range |
0.15 ~1.0MPa | |
Pilot pressure range |
Same to pressure of main valve or higher. | |
AMBIENT TEMPERATURE | 5 ~ 60°C | |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | |
OPERATING PRESSURE | 0.15 ~1.0MPa | |
Main pressure range |
0.15 ~1.0MPa | |
Pilot pressure range |
Same to pressure of main valve or higher. | |
AMBIENT TEMPERATURE | 5 ~ 60°C | |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | ||
OPERATING PRESSURE | 0.05 ~1.0MPa | ||
Main pressure range |
0.05 ~ 0.15MPa | 0.15 ~ 1.0MPa | |
Pilot pressure range |
0.15 ~ 0.3MPa | Same to pressure of main valve or higher. |
|
AMBIENT TEMPERATURE | 5 ~ 60°C | ||
PROOF PRESSURE | 1.6MPa | ||
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
* Pilot pressure must not exceed 1.0MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | ||
OPERATING PRESSURE | 0.05 ~1.0MPa | ||
Main pressure range |
0.05 ~0.15MPa | 0.15 ~ 1.0MPa | |
Pilot pressure range |
0.15 ~ 0.3MPa | Same to pressure of main valve or higher. |
|
AMBIENT TEMPERATURE | 5 ~ 60°C | ||
PROOF PRESSURE | 1.6MPa | ||
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
![]() 360 Super Poppet SERIES |
![]() 360 Super Poppet SERIES (High-Low Pressure change) |
![]() 392 SERIES (FOR COMPRESSED AIR & VACUUM) |
SPECIFICATIONS
FLUID | Filtered Compressed Air | ||
OPERATING PRESSURE | 0.05 ~1.0MPa | ||
Main pressure range |
0.05 ~ 0.15MPa | 0.15 ~ 1.0MPa | |
Pilot pressure range |
0.15 ~ 0.3MPa | Same to pressure of main valve or higher. |
|
AMBIENT TEMPERATURE | 5 ~ 60°C | ||
PROOF PRESSURE | 1.6MPa | ||
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
* Pilot pressure must not exceed 1.0MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | |
SERVICING PRESSURE |
Master valve pressure range* |
Higher Pressure side (IN) 0.05 ~1.0MPa |
Lower Pressure side (EX) 0 ~ 0.85MPa |
||
Pilot air pressure setting of pilot air pressure* |
P = Higher pressure side (IN) + 0 ~ 0.2MPa |
|
P = Lower pressure side (EX) + 0.15MPa |
||
AMBIENT TEMPERATURE | 5 ~ 60°C | |
PROOF PRESSURE | 1.6MPa | |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* High side pressure (=IN PORT), Lower side pressure (=EX PORT)
* Pilot air pressure must be lower than 1.0MPa (=10kgf/cm²).
SPECIFICATIONS
FLUID | Filtered Compressed Air | Vacuum |
OPERATING PRESSURE | 0 ~ 0.7MPa | – 0.1 ~ 0MPa |
AMBIENT TEMPERATURE | 5 ~ 50°C | |
LUBRICANTS | Can use without lubrication | |
MANUAL OPERATION | Manual push button / Non-lock type | |
RATED VOLTAGE | ● AC-100V 50/60Hz, 110V 60Hz ● AC-200V 50/60Hz, 220V 60Hz ● DC-24V |
|
VOLTAGE ALLOWANCE | -15 ~ 10% | |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Filtered Compressed Air | ||
OPERATING PRESSURE | 0.05 ~1.0MPa | ||
Main pressure range |
0.05 ~ 0.15MPa | 0.15 ~ 1.0MPa | |
Pilot pressure range |
0.15 ~ 0.3MPa | Same to pressure of main valve or higher. |
|
AMBIENT TEMPERATURE | 5 ~ 60°C | ||
PROOF PRESSURE | 1.6MPa | ||
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
* When the pilot pressure is higher than the pressure supplied to the main valve, the differential pressure should be less than 0.3MPa.
* Pilot pressure must not exceed 1.0MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | ||
OPERATING PRESSURE | 0 ~ 1.0MPa | ||
AMBIENT TEMPERATURE | 5 ~ 60°C | ||
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
SPECIFICATIONS
FLUID | Filtered Compressed Air | ||
OPERATING PRESSURE | 0 ~ 1.0MPa | ||
AMBIENT TEMPERATURE | 5 ~ 60°C | ||
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
||
HANDLE ROTATION ANGLE |
At actuated position, rotation angle to clock- with or anticlockwise direction is 45° |