SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.15 ~ 0.9MPa |
AMBIENT TEMPERATURE | 5 ~ 50°C |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
Pipe Size |
“1” “3” “5” port (common port) |
Rc 1/4 (on sides of manifold block) |
“2” “4” port (separate port) |
Rc 1/4 (on each valve body) | |
Effective Area (IN-OUT/OUT-EX) |
21/18mm² 2 position Single / Double solenoid | |
18/13mm² 3 position Double solenoid | ||
Max. no. of valves possible on the manifold block |
8 |
* Other specifications are common to 501 Series, In-line type.
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.2 ~ 0.95MPa (Internal Pilot Supply type) |
0 ~ 0.95MPa (External Pilot Supply type) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C |
LUBRICANTS | ISO VG 32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
Pipe Size |
“1” “3” “5” port (common port) |
Rc 3/8 (on both end plates) |
“2” “4” port (separate port) |
Rc 1/4 or Rc 3/8 (on each valve body) | |
Effective Area | 35mm² | |
Maximum number of valves available for forming stack manifold |
8 |
* Other specifications are common to 495Y Series, In-line type.
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.2 ~ 0.95MPa (Internal Pilot Supply type) |
0 ~ 0.95MPa (External Pilot Supply type) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
Pipe Size |
“1” “3” “5” port (common port) |
Rc 1/2 (on manifold block) |
“2” “4” port (separate port) |
Rc 1/4 or Rc 3/8 (on manifold block) | |
Effective Area | 35mm² | |
Maximum number of valves available for manifold |
10 |
* Other specifications are common to 492Y Series, Sub-base type.
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.2 ~ 1.0MPa (Internal Pilot Supply type) |
0 ~ 1.0MPa (External Pilot Supply type) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
Port Size |
“1” “3” “5” common ports |
Rc 3/4 |
“2” “4” port Each valve port |
Rc 3/8 , Rc 1/2 or Rc 3/4 | |
Effective Area | 75mm² | |
Maximum No. of valves available for manifold |
6 |
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.15 ~ 1.0MPa (Internal Pilot Supply type) |
0 ~ 1.0MPa (External Pilot Supply type) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C |
LUBRICANTS | Turbine oil ISO VG 32 or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0 ~ 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 50°C |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.15 ~1.0MPa (Internal Pilot Supply type) |
0.05 ~ 1.0MPa (External Pilot Supply type) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C |
PROOF PRESSURE | 1.6MPa |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.15 ~1.0MPa (Internal Pilot Supply type) |
0.05 ~ 1.0MPa (External Pilot Supply type) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C |
PROOF PRESSURE | 1.6MPa |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
![]() 360 Super Poppet SERIES |
![]() 360 Super Poppet SERIES (vacuum) |
![]() 360 Super Poppet SERIES (High-Low pressure change) |
![]() 360 Super Poppet SERIES (vacuum) |
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.15 ~1.0MPa (Internal Pilot Supply type) |
0.05 ~ 1.0MPa (External Pilot Supply type) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C |
PROOF PRESSURE | 1.6MPa |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Vacuum (air) |
OPERATING PRESSURE | – 0.1 ~ –0.01MPa (External Pilot Supply Type only) |
EXTERNAL PILOT SUPPLY PRESSURE | 0.2 ~ 0.3MPa |
AMBIENT TEMPERATURE | 5 ~ 50°C |
PROOF PRESSURE | 1.6MPa |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Filtered Compressed Air | |
OPERATING PRESSURE | Pressure Range of Main Valve Side* |
High Pressure Side (IN): 0.05 ~1.0MPa |
Low Pressure Side (EX): 0 ~ 0.85MPa |
||
Pilot Pressed: Set of P* |
P = High Pressure Side (IN) Pressure + 0 ~ 0.2MPa Besides P = Low Pressure Side (EX) Pressure + 0.15MPa |
|
AMBIENT TEMPERATURE | 5 ~ 50°C | |
PROOF PRESSURE | 1.6MPa | |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. (Non-Lubrication is also available) |
|
MANUAL OPERATION | Manual push button / Non-lock type | |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
|
VOLTAGE ALLOWANCE | –15 ~ 10% | |
INSULATION GRADE | Class B |
*1. Higher pressure side = (IN PORT), Lower pressure side = (EX PORT)
*2. Pilot air should be lower than 1.0MPa
*3.Operating pressure range of 36B series (Rc11/4 ~ Rc2) is 0.2 ~ 1.0MPa.
SPECIFICATIONS
FLUID | Filtered Compressed Air | Vacuum |
OPERATING PRESSURE | 0 ~ 0.7MPa | – 0.1 ~ 0MPa |
AMBIENT TEMPERATURE | 5 ~ 50°C | |
LUBRICANTS | Can use without lubrication | |
MANUAL OPERATION | Manual push button / Non-lock type | |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V |
|
VOLTAGE ALLOWANCE | –15 ~ 10% | |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Compressed Air | Liquid* | Vacuum |
OPERATING PRESSURE RANGE | 0.02 ~ 0.7MPa | 0.15 ~ 0.7MPa | – 0.08 ~ 0MPa |
AMBIENT TEMPERATURE | 5 ~ 50°C | ||
LUBRICANT | Required | ||
MANUAL OPERATION | Nil | ||
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
||
VOLTAGE ALLOWANCE | –15 ~ 10% | ||
INSULATION GRADE | Class B |
* Use non-corrosive and low viscosity liquid.
BASIC MODEL NOs. & OTHER SPECIFICATIONS
Pipe Size |
MODEL NUMBER | Effective Area [mm²] < Cv value > |
||
Single Solenoid Normally Closed | Mass [kg] |
|||
Compressed Air / Liquid | Vacuum | |||
Rc 1/4 | MVS-2202Y | MVS-2202YV | 0.5 | 35 < 1.9 > |
Rc 3/8 | MVS-2203Y | MVS-2203YV | 40 < 2.2 > | |
Rc 1/2 | MVS-2204JY | MVS-2204JYV |
Pipe Size |
MODEL NUMBER | Effective Area [mm²] < Cv value > |
||
Single Solenoid Normally Closed | Mass [kg] |
|||
Compressed Air / Liquid | Vacuum | |||
Rc 1/2 | MVS-2304Y | MVS-2304YV | 1.5 | 110 < 5.9 > |
Rc 3/4 | MVS-2306Y | MVS-2306YV | 170 < 9.2 > | |
Rc1 | MVS-2310Y | MVS-2310YV | 240 < 13.0 > | |
Rc1 1/4 | MVS-2312JY | MVS-2312JYV | 350 < 18.9 > |
SPECIFICATIONS
FLUID | Filtered Compressed Air |
OPERATING PRESSURE | 0.15 ~1.0MPa (Internal Pilot Supply type) |
0.05 ~ 1.0MPa (External Pilot Supply type) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C |
PROOF PRESSURE | 1.6MPa |
LUBRICANTS | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Vacuum (air) |
OPERATING PRESSURE | – 0.1 ~ 0MPa (External Pilot Supply type only) |
EXTERNAL PILOT SUPPLY PRESSURE | 0.2 ~ 0.3MPa |
AMBIENT TEMPERATURE | 5 ~ 50°C |
MANUAL OPERATION | Manual push button / Non-lock type |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V • DC-100V |
VOLTAGE ALLOWANCE | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
354 Series | MVS-3500Y Series | |
FLUID | Filtered Compressed Air | |
OPERATING PRESSURE | 0.20 ~ 0.85MPa (Internal Pilot) |
0.15 ~ 0.8MPa (Internal Pilot) |
0.05 ~ 0.85MPa (External Pilot) |
0.05 ~ 0.8MPa (External Pilot) |
|
AMBIENT TEMPERATURE | 5 ~ 50°C | |
LUBRICANTS | Available without supplying oil. (No lubrication) | ISO VG32 turbine oil, or equivalent oil is recommended. |
MANUAL OPERATION | Mnual push button / Non-lock type | |
RATED VOLTAGE | • AC-100V 50/60Hz, 110V 60Hz • AC-200V 50/60Hz, 220V 60Hz • DC-24V |
|
VOLTAGE ALLOWANCE | ±10% | –15 ~ 10% |
INSULATION GRADE | Class B |
SPECIFICATIONS
FLUID | Exhaust Air |
MAX. OPERATING PRESSURE | 1.0MPa |
AMBIENT TEMPERATURE | 5 ~ 60°C |
EXHAUST NOISE REDUCTION RATE | More than 20 dB (A) |
NOISE REDUCING ELEMENT | SL-00 Series: sintered brass MFF-200 Series: plastic foam MFF-300 Series: wire-mesh element, or non-woven sheet. |
MODEL NOs. & OTHER SPECIFICATIONS
Pipe Size |
MODEL NUMBER | Effective Area (mm²)<Cv> |
Mass (kg) |
R 1/4 | SL-02 | 40 < 2.2 > | 0.02 |
R 3/8 | SL-03 | 60 < 3.2 > | 0.03 |
R 1/2 | MFF-204 | 115 < 6.2 > | 0.09 |
R 3/4 | MFF-306A | 230 < 12.4 > | 0.20 |
R1(Rc1) | MFF-310 | 330 < 17.8 > | 0.62 |
Rc1 1/4 | MFF-312 | 915 < 49.4 > | 0.9 |
Rc1 1/2 | MFF-314 | 975 < 52.7 > | |
Rc2 | MFF-320 | 1400 < 75.6 > | 1.5 |